The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A New Biometrical Procedure for Testing the Equality of Measurements from Two Different Analytical Methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part I
Open accessAbstract
Procedures for the statistical evaluation of method comparisons and instrument tests often have a requirement for distributional properties of the experimental data, but this requirement is frequently not met. In our paper we propose a new linear regression procedure with no special assumptions regarding the distribution of the samples and the measurement errors. The result does not depend on the assignment of the methods (instruments) to X and Y. After testing a linear relationship between X and Y confidence limits are given for the slope beta and the intercept alpha; they are used to determine whether there is only a chance difference between beta and 1 and between alpha and 0. The mathematical background is amplified separately in an appendix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Regression analysis according to Passing and Bablok 30 showed that slopes between the BGMS and the GOD method ranged from 0.85 to 1.08 and from 0.81 to 1.01 when compared with the HK method.”
From Impact of Two Different Reference Measurement Procedures on Apparent System Accuracy of 18 CE-Marked Current-Generation Blood Glucose Monitoring Systems (2022) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Statistical Methods
(1999) · Technometrics · doi:10.1080/00401706.1999.10485954 · Cited by 6,118
Distribution-Free Statistical Tests
Bell, C. B., & Bradley, J. V. (1970) · Technometrics · doi:10.1080/00401706.1970.10488744 · Cited by 1,703
Distribution-Free Statistical Methods.
Hora, S. C., & Maritz, J. S. (1984) · Journal of the American Statistical Association · doi:10.2307/2288300 · Cited by 154
Cumulative Sum Tests: Theory and Practice
Burr, I. W., & de Bruyn, C. S. V. D. (1969) · Technometrics · doi:10.2307/1267036 · Cited by 138
Linear Free Energy Relationships as Tools for Investigating Chemical Similarity—Theory and Practice
Wold, S., & Sjöstróm, M. (1978) · Springer eBooks · doi:10.1007/978-1-4615-8831-3_1 · Cited by 19
Robuste Schätzung im Linearen Modell
Heiler, S. (1980) · Medizinische Informatik und Statistik · doi:10.1007/978-3-642-81511-9_4 · Cited by 3
Praktische Erfahrung mit R-robusten Verfahren bei klinischen Versuchen
Wolf, G. K. (1980) · Medizinische Informatik und Statistik · doi:10.1007/978-3-642-81511-9_7 · Cited by 2
Research works printed but not linked: 3
- Bablok, 1983, is obtained No Passing and ncw procedure for testing the cquality of mcasurements from two methods If we substitute the structural relationship in the de - finition of the S - we find y t - y t - - From yf ßx and djj we get o ß djj - - dij, Clin Chem Clin Biochem, 21
- Bablok, 1983, Clearly the new procedure takes into account the experimental reality of method comparisons s de - scribed in chapter No Passing and new procedure for testing the eq ality of measurements from two methods ϋ er ί - α CD α σ ρ - σ ο χ : i - ο ο : σα ε ο, Clin Chem Clin Biochem, 2, 3
- Bablok, 1983, and Biochern No Passing and new procedure for testing the equality of measurements from two methods It follows that : sup and max l cusum i hY V l, Clin Chern, 0
Cited by
Sorted by citations
Items 801–900 of 1,001
Kruse, N., Heslegrave, A., Gupta, V., Foiani, M. S., Villar‐Piqué, A., Schmitz, M., Lehmann, S., Teunissen, C. E., Blennow, K., Zetterberg, H., et al. (2018) · Alzheimer s & Dementia Diagnosis Assessment & Disease Monitoring · doi:10.1016/j.dadm.2018.06.005 · Cited by 11
Dried Urine Swabs as a Tool for Monitoring Metabolite Excretion
Monošík, R., & Dragsted, L. O. (2018) · Bioanalysis · doi:10.4155/bio-2018-0042 · Cited by 11
Post marketing study of hemodynamic and hematological noninvasive readings in a blood bank
Segman, Y. J., & Sheiman, E. (2018) · SAGE Open Medicine · doi:10.1177/2050312118796065 · Cited by 25
Atomization behaviour of juice-fibre suspensions in a two-fluid nozzle
Rozali, S. N. M., Paterson, A. H. J., Hindmarsh, J. P., & Huffman, L. M. (2019) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2019.03.017 · Cited by 11
Non-invasive estimation of brain-volume in infants
Burkhardt, W., Schneider, D. G., Hahn, G., Konstantelos, D., Maas, H., & Rüdiger, M. (2019) · Early Human Development · doi:10.1016/j.earlhumdev.2019.03.020 · Cited by 12
Schoos, A., Spiegelaere, W. D., Cools, A., Pardon, B., Audenhove, E. V., Bernaerdt, E., Janssens, G., & Maes, D. G. D. (2020) · animal · doi:10.1016/j.animal.2020.100041 · Cited by 11
Influence of irisin on diet-induced metabolic syndrome in experimental rat model
Medhat, D., El‐Bana, M. A., El‐Daly, S. M., Ashour, M. N., Elias, T. R., Mohamed, R. A., Yassen, N. N., Abdel-Monem, M. A., & Hussein, J. (2021) · Journal of Complementary and Integrative Medicine · doi:10.1515/jcim-2020-0030 · Cited by 11
Evaluation of a new automated immunoassay for the quantification of anti-Müllerian hormone
Lotierzo, M., Urbain, V., Dupuy, A., & Cristol, J. (2021) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2021.e00220 · Cited by 11
Scuderi, C. E., Parker, S. L., Jacks, M., John, G. T., McWhinney, B. C., Ungerer, J. P. J., Mallett, A. J., Healy, H. G., Roberts, J. A., & Staatz, C. E. (2023) · Kidney Medicine · doi:10.1016/j.xkme.2023.100610 · Cited by 11
BLIJENBERG, B. G., Lilja, H. G., Neels, H. M., & Stenman, U. (2003) · British Journal of Urology · doi:10.1111/j.1465-5101.2003.04401.x · Cited by 11
Kleine, T. O., Nebe, C. T., Löwer, C., Lehmitz, R., Kruse, R., Geilenkeuser, W., & Dorn‐Beineke, A. (2009) · Cytometry Part A · doi:10.1002/cyto.a.20753 · Cited by 11
Bonn Risk Index Based Micromethod for Assessing Risk of Urinary Calcium Oxalate Stone Formation
Porowski, T., Mrozek, P., Sidun, J., Zoch-Zwierz, W. M., Konstantynowicz, J., Kirejczyk, J. K., Motkowski, R., & Laube, N. (2010) · The Journal of Urology · doi:10.1016/j.juro.2009.11.054 · Cited by 11
Comparison of dual-source and electron-beam CT for the assessment of coronary artery calcium scoring
Reinsch, N., Mahabadi, A. A., Lehmann, N., Möhlenkamp, S., Hoefs, C., Sievers, B., Budde, T., Seibel, R., Jöckel, K.-H., & Erbel, R. M. (2012) · British Journal of Radiology · doi:10.1259/bjr/91904659 · Cited by 11
Schmidt, H. H.-J., Genschel, J., Wagner, S., & Manns, M. P. (1996) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1996.34.2.119 · Cited by 11
Analytical performance comparison of five new generation immunoassay analyzers
Hendriks, H. A., & Kortlandt, W. (2000) · Cited by 11
Yun, C., Chen, J., Yang, C., Li, Y., Piao, J., & Yang, X. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.06.007 · Cited by 11
Aufenanger, J., & Kattermann, R. (1989) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1989.27.9.605 · Cited by 11
A Time-Resolved Fluoroimmuno Assay of the IgM-Rheumatoid Factor
Veer, G. V. D. S., & Soons, J. W. P. H. (1992) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1992.30.5.301 · Cited by 11
Häfner, G. (2001) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655101300133667 · Cited by 11
Evaluation of the First Automated Thyroglobulin Assay
Vogeser, M., Knesewitsch, P., Jacob, K., & Seidel, D. (1999) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1999.028 · Cited by 11
CDTect-RIA AND CDTect-EIA FOR DETERMINATION OF SERUM CARBOHYDRATE-DEFICIENT TRANSFERRIN COMPARED
Arndt, T., Kröpf, J., Brandt, R., Gressner, A. M., Hackler, R., Herold, M., PELT, J. V., Mårtensson, O., Salzmann, K., & Velmans, M. H. (1998) · Alcohol and Alcoholism · doi:10.1093/alcalc/33.6.639 · Cited by 11
Evaluation of Performance Characteristics of Automated Measurement Systems for Allergy Testing
Costongs, G. M. P. J., Pc, J., Hermans, W. J. T. A., Oers, R. J. M. V., & Leerkes, B. (1995) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1995.33.5.295 · Cited by 11
Fecteau, K. M., Winchell, A. J., Blue, S. W., Appleman, M. L., Urbanski, H. F., & Erikson, D. W. (2024) · Biology of Reproduction · doi:10.1093/biolre/ioae063 · Cited by 10
Chavda, S., Sandau, I., Bishop, C. J., Xu, J., Turner, A. N., & Lake, J. P. (2024) · Applied Sciences · doi:10.3390/app14167397 · Cited by 10
Reed, K., Dang, C., Walkup, J., Purcell, A. M., Hungate, B. A., & Morrissey, E. M. (2025) · Applied and Environmental Microbiology · doi:10.1128/aem.01849-24 · Cited by 10
Performance characteristics of the VERSANT hepatitis C virus RNA 1.0 (kPCR) assay
Grüner, N., Viazov, S. O., Korn, K., Knöll, A., Trippler, M., Schlaak, J., Gerken, G., Roggendorf, M., & Roß, R. S. (2015) · International Journal of Medical Microbiology · doi:10.1016/j.ijmm.2015.08.012 · Cited by 10
Wade, D., Diaw, P. A., Daneau, G., Diallo, A. A., Mboup, S., Dièye, T. N., & Kestens, L. (2015) · PLoS ONE · doi:10.1371/journal.pone.0116663 · Cited by 10
Ceulemans, A., Bouzahzah, C., Prat, I., Urassa, W. K., & Kestens, L. (2019) · PLoS ONE · doi:10.1371/journal.pone.0209677 · Cited by 10
Göpfert, J. C., Reiser, A., Yañez, V. A. C., Pohle, A., Wessels, U., Heine, A., Joos, T. O., Petit-Frère, C., Nogoceke, E., & Stubenrauch, K. (2019) · Bioanalysis · doi:10.4155/bio-2019-0044 · Cited by 11
EVALUATION OF PROGNOSTIC INDICATORS FOR INJURED TURTLES PRESENTING TO A WILDLIFE CLINIC
Gregory, T. M., Hubbard, C., Schlake, E. L., Mejía, D. S., Passingham, R. K., Lewbart, G. A., & Harrison, T. M. (2022) · Journal of Zoo and Wildlife Medicine · doi:10.1638/2020-0200 · Cited by 10
Light excitation of gold Nanorod-Based hybrid nanoplatforms for simultaneous bimodal phototherapy
Arellano, L., Villar‐Álvarez, E., Velasco, B., Domínguez-Arca, V., Prieto, G., Cambón, A., Barbosa, S., & Taboada, P. (2023) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2023.121511 · Cited by 10
Stehlé, T., Wei, F., Brabant, S., Luciani, A., Grimbert, P., Prié, D., Reizine, É., Dürrbach, A., Mulé, S., Lesne-Hulin, A., et al. (2023) · Radiology · doi:10.1148/radiol.230567 · Cited by 10
Lee, P., DuMontier, C., Yu, W., Ask, L., Zhou, J., Testa, M. A., Kim, D. H., Abel, G. A., Travison, T., Manor, B. D., et al. (2024) · Bioengineering · doi:10.3390/bioengineering11030257 · Cited by 11
Culibrk, B., Stone, E. J., Levin, E., Weiss, S., Serrano, K., & Devine, D. V. (2012) · Vox Sanguinis · doi:10.1111/j.1423-0410.2012.01601.x · Cited by 9
Lin, H., Liao, C.-C., & Lin, T.-C. (2014) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6997 · Cited by 10
Pinto, I. C. P., Sabidó, M., Pereira, A. B., Mello, M. B., Shimizu, A. D. M. X., Wohlk, B. L. P., & Benzaken, A. S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0121400 · Cited by 10
Santos, J., Vicente, J., Villamuelas, M., Albanell, E., Serrano, E., Carvalho, J., Fonseca, C. M. D., Gortázar, C., & Lopez‐Olvera, J. R. (2014) · Ecological Indicators · doi:10.1016/j.ecolind.2014.05.021 · Cited by 12
Xia, C., Liu, O., Wang, L., & Xu, G. (2012) · Annals of Laboratory Medicine · doi:10.3343/alm.2012.32.4.243 · Cited by 10
Mbopi‐Kéou, F., Mion, S., Sagnia, B., & Bélec, L. (2012) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00023-12 · Cited by 10
Sadler, R. A., Hall, N. H., Kass, P. H., & Citino, S. B. (2013) · Journal of Zoo and Wildlife Medicine · doi:10.1638/2012-0292r1.1 · Cited by 10
Sarrazin, F., Tessler, M. J., Kardash, K. J., McNamara, E. A., & Holcroft, C. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9082-z · Cited by 10
The diagnostic value of two commercially available human cTnI assays in goat kids with myocarditis
Karapınar, T., Eröksüz, Y., Hayırlı, A., BEYTUT, E., Kaynar, Ö., Baydar, E., Sözdutmaz, İ., & Işıdan, H. (2016) · Veterinary Clinical Pathology · doi:10.1111/vcp.12328 · Cited by 10
Barclay, J. L., Keshvari, S., Whitehead, J. P., & Inder, W. J. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563216628891 · Cited by 10
Comparison of a non-contact infrared thermometer with a rectal digital thermometer for use in ewes
Katsoulos, P. D., Athanasiou, L. V., Karatzia, M. A., Valasi, I., Boscos, C., & Karatzias, H. (2016) · Small Ruminant Research · doi:10.1016/j.smallrumres.2016.09.004 · Cited by 10
Measuring zinc on the Roche cobas c502 analyzer—Validation, comparison, and pre‐analytic aspects
Kraus, F. B., & Ludwig‐Kraus, B. (2017) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22169 · Cited by 11
Osbak, K. K., Abdellati, S., Tsoumanis, A., Esbroeck, M. V., Kestens, L., Crucitti, T., & Kenyon, C. R. (2017) · Journal of Medical Microbiology · doi:10.1099/jmm.0.000559 · Cited by 10
Development and Validation of an Ultrasensitive Procalcitonin Sandwich Immunoassay
Yañez, V. A. C., Göpfert, J. C., Otto, M., Tumani, H., Peter, A., & Joos, T. O. (2017) · Microarrays · doi:10.3390/ht6040018 · Cited by 10
Cekic, N. D., Savic, S. M., & Savic, S. D. (2019) · Drug Development and Industrial Pharmacy · doi:10.1080/03639045.2019.1672718 · Cited by 11
Jin, S., Zhao, Q., Zhang, D., Zhao, Z., & Mei, S. (2019) · Journal of Analytical Science & Technology · doi:10.1186/s40543-019-0198-9 · Cited by 10
Vermeiren, E., Ysebaert, M., Hoorenbeeck, K. V., Bruyndonckx, L., Dessel, K. V., Helvoirt, M. V., Guchtenaere, A. D., Winter, B. Y. D., Verhulst, S. L., & Eyck, A. V. (2020) · European Journal of Clinical Nutrition · doi:10.1038/s41430-020-00738-9 · Cited by 10
Androgens by immunoassay and mass spectrometry in children with 46,XY disorder of sex development
de Oliveira, L. R., Longui, C. A., Guaragna‐Filho, G., Costa, J. L., Lanaro, R., Silva, D. A., Chiamolera, M. I., de Mello, M. P., Morcillo, A. M., Maciel‐Guerra, A. T., et al. (2020) · Endocrine Connections · doi:10.1530/ec-20-0454 · Cited by 10
Weiss, T. L. D., Gössling, G. C. D. L., Antunes, M. V., Schwartsmann, G., Linden, R., & Verza, S. G. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113861 · Cited by 10
Scholer, A., Böcker, J., Engelmayer, U., Feldmann, K., Hannak, D., Kattermann, R., Oellerich, M., Raith, H., Schlebusch, H., Wieland, H., et al. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.1.92 · Cited by 10
Ghadge, M. S., Naik, P. P., Tiwari, B. P., Hegde, R. M., & Matale, T. J. (2011) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-011-0168-5 · Cited by 10
Font, M. T. C., Brichs, M. C. S., Álvarez, M. C. S., Olivella, J. M. N., Turó, J. S., & Fernández, M. P. F. (2011) · Atención Primaria · doi:10.1016/j.aprim.2010.09.017 · Cited by 10
Ishida, J., Suzuki, T., Aizawa, K., Sawaki, D., & Nagai, R. (2012) · International Heart Journal · doi:10.1536/ihj.53.320 · Cited by 10
Davani, S., Bérard, M., Royer, B., Kantelip, J., & Muret, P. (2004) · Pathologie Biologie · doi:10.1016/j.patbio.2004.07.033 · Cited by 10
D’Alfonso, T. M., van Laar, R. K., Vahdat, L. T., Hussain, W. M., Flinchum, R., Brown, N., John, L. S., & Shin, S. J. (2013) · Breast Cancer Research and Treatment · doi:10.1007/s10549-013-2604-0 · Cited by 10
Signò, P., Barassi, A., Novario, R., & d’Eril, G. V. M. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.149 · Cited by 10
Ratzinger, F., Schmetterer, K. G., Haslacher, H., Perkmann, T., Belik, S., & Quehenberger, P. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-1094 · Cited by 10
Mei, S., Wang, J., Chen, D., Zhu, L., Zhao, M., Hu, X., Li, Y., & Zhao, Z. (2017) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000477 · Cited by 10
van Helden, J., & Weiskirchen, R. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.09.009 · Cited by 10
Gürtler, C., Laible, M., Schwabe, W., Steinhäuser, H., Li, X., Liu, S., Schlombs, K., & Şahin, U. (2018) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2018.02.004 · Cited by 9
Dolscheid‐Pommerich, R., Kirchner, S., Weigel, C., Eichhorn, L., Conrad, R., Stoffel‐Wagner, B., & Zur, B. (2015) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2015.01.034 · Cited by 11
Reference values and methods comparison of a new testosterone assay on the AxSYM system
Sagrado, M. G., Gil, F. J. M., López-Hernández, S., Fernández-García, N., Olmos-Linares, A. M., & Arranz-Peña, M. L. (2000) · Clinical Biochemistry · doi:10.1016/s0009-9120(00)00057-6 · Cited by 10
Schlebusch, H., & Mende, S. (1991) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1991.29.1.57 · Cited by 10
Casal, J. A., Amparo Chabás, B., & Tutor, J. C. (2002) · American Journal of Medical Genetics Part A · doi:10.1002/ajmg.a.10891 · Cited by 10
Determination of MEGX by HPLC with Fluorescence Detection
Андреева, М. В., Niedmann, P. D., Schütz, E., Wieland, E., Armstrong, V. W., & Oellerich, M. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.6.1081 · Cited by 10
Laube, N., Hergarten, S., & Hesse, A. (2002) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2002.102 · Cited by 10
Veldhuizen, G. P., Alnazer, R. M., Kroon, A. A., & de Leeuw, P. W. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003257 · Cited by 9
Kurihara, M., Kondo, S., Ohse, K., Nojima, H., Kikkawa-Saito, E., & Iwata, A. (2024) · Journal of Alzheimer s Disease · doi:10.3233/jad-240185 · Cited by 8
Clinical vs. statistical significance: considerations for clinical laboratories
Hakan, H., Tran, M. T. C., Markus, C., Ho, C. S., Loh, T. P., Zakaria, R., Cooke, B. R., Theodorsson, E., & Greaves, R. F. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0219 · Cited by 10
Nevarez, J. G., Acierno, M. J., Angel, M., & Beaufrère, H. (2012) · Journal of Herpetological Medicine and Surgery · doi:10.5818/1529-9651-22.1-2.36 · Cited by 9
Méthode simplifiée de mesure de la concentration en pepsinogène dans le serum
Kerbœuf, D., Kock, C., Le Drean, E., & Lacourt, A. (2002) · HAL · Cited by 9
Urinary steroid profiles: comparison of spot and 24-hour collections
Bileck, A., Frei, S., Vogt, B., & Groessl, M. (2020) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2020.105662 · Cited by 9
Agreement of Tear Break-Up Time and Meniscus Height between Medmont E300 and Visionix VX120+
Plaza, E. M., Molina‐Martín, A., & Pinero, D. P. (2022) · Applied Sciences · doi:10.3390/app12094589 · Cited by 9
Lin, Z., Lin, Q., Yu, P., Chen, Z., Lin, H., Zhu, B., Wang, M., & Cao, Y. (2022) · Annals of Translational Medicine · doi:10.21037/atm-22-1642 · Cited by 10
Žabota, B., Berger, F., & Kobal, M. (2023) · Drones · doi:10.3390/drones7020104 · Cited by 9
Comparing the use of chloroform to petroleum ether for Soxhlet extraction of fat in meat
Watkins, P. (2023) · Animal Production Science · doi:10.1071/an23014 · Cited by 9
Egelé, A., van Gelder, W., & Riedl, J. (2015) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12399 · Cited by 9
Comparative evaluation of two newly developed devices for capillary viscometry.
Holdt, B., Lehmann, J. K., & Schuff‐Werner, P. (2005) · PubMed · Cited by 9
Crofton, P. M., Squires, N., Davidson, D. F., Henderson, P., & Taheri, S. (2008) · European Journal of Pediatrics · doi:10.1007/s00431-008-0733-y · Cited by 9
Selleri, P., & Girolamo, N. D. (2014) · Journal of the American Animal Hospital Association · doi:10.5326/jaaha-ms-6114 · Cited by 9
Park, K., Park, M.-S., Cha, Y.-J., Kim, W., Choi, S.-S., Kim, K. O., Cha, E., & Kim, K.-A. (2010) · Annals of Laboratory Medicine · doi:10.3343/kjlm.2010.30.3.264 · Cited by 9
Is manual reticulocyte count a reliable option for under resourced countries?
Ali, A. F., Moiz, B., & Omer, S. (2010) · PubMed · Cited by 9
Reliability of the Determination of the Ventilatory Threshold in Patients with COPD
Dubé, B., Mesbahi, M., Beaucage, F., & Pepin, V. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000770 · Cited by 8
Sorio, D., Palo, E. F. D., Bertaso, A., Bortolotti, F., & Tagliaro, F. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0069-9 · Cited by 9
Mucci, N., Dugheri, S., Bonari, A., Farioli, A., Rapisarda, V., Garzaro, G., Cappelli, G., & Arcangeli, G. (2020) · International Journal of Occupational Medicine and Environmental Health · doi:10.13075/ijomeh.1896.01508 · Cited by 9
Yoshikawa, N., Yamada, A. Y., Yokota, T., Moritake, H., Hirabara, Y., & Ikeda, R. (2020) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23661 · Cited by 9
Using a fingerstick test for haematological monitoring in patients treated with clozapine
Atkins, M., McGuire, P. K., Balgobin, B., Patel, P., & Taylor, D. M. (2021) · Therapeutic Advances in Psychopharmacology · doi:10.1177/20451253211000865 · Cited by 9
Charlier, B., Coglianese, A., Operto, F. F., Rosa, F. D., Mensitieri, F., Coppola, G., Filippelli, A., Piaz, F. D., & Izzo, V. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114252 · Cited by 10
Chen, D., Huang, Y.-H., Chen, Y., Chen, J. J. W., Yang, T.-Y., Chang, G., & Tang, K. (2021) · Lupus Science & Medicine · doi:10.1136/lupus-2021-000562 · Cited by 10
Hellqvist, A., Heiene, R., Baere, S. D., Croubels, S., & Hedeland, Y. (2014) · Biomedical Chromatography · doi:10.1002/bmc.3304 · Cited by 9
Schoonenboom, N. S. M., Mulder, C., Vanderstichele, H., Pijnenburg, Y. A. L., van Kamp, G. J., Scheltens, P., Mehta, P. D., & Blankenstein, M. A. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.048629 · Cited by 10
Seis sigma no laboratório clínico: impacto na gestão de performance analítica dos processos técnicos
Berlitz, F. D. A., & Haussen, M. L. (2005) · Jornal Brasileiro de Patologia e Medicina Laboratorial · doi:10.1590/s1676-24442005000500004 · Cited by 9
Bonfigli, A. R., Coppa, G., Testa, R., Testa, I., & Sio, G. D. (1997) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1997.35.1.57 · Cited by 9
[Oral and nutritional health status in children attending a school in Cartagena, 2009].
Martínez, K. R., Martínez, F. D. G., & Luna-Ricardo, L. (2010) · PubMed · Cited by 9
Evaluation of the CELL-DYN ® 3500 Haematology Instrument for the Analysis of the Mouse and Rat Blood
Kieffer, J., Winkler, G. C., Hove, L. V., Walsh, A., Thomann, P., Wyss, S., Eggenberger, E., & Lutz, H. (1999) · Comparative Clinical Pathology · doi:10.1007/bf02585543 · Cited by 9
Sardinha, L. B., Silva, A. M., & Teixeira, P. J. (2003) · Acta Diabetologica · doi:10.1007/s00592-003-0029-7 · Cited by 10
Chemical Analysis of Gallstones
Steen, G., & BLIJENBERG, B. G. (1991) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1991.29.12.801 · Cited by 9
Metadata
- Authors
- Passing, H., & Bablok, W.
- Venue
- cclm
- Publisher
- Walter de Gruyter GmbH
- Published
- 1983
- Volume
- 21
- Issue
- 11
- Pages
- 709-720
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2020210187
- Cited by
- 1,513
- References
- 7
- Citations by year
- 2026: 32 · 2025: 67 · 2024: 60 · 2023: 84 · 2022: 63 · 2021: 70 · 2020: 86 · 2019: 72 · 2018: 64 · 2017: 72 · 2016: 67 · 2015: 74 · 2014: 61 · 2013: 50 · 2012: 48
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- edoc Publication server (Humboldt University of Berlin) (submittedVersion)
- edoc Publication server (Humboldt University of Berlin)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- method comparison, linear regression, measurement error, distribution-free statistics, clinical chemistry instrumentation
- MeSH terms
- Biometry, Chemistry, Clinical, Humans, Quality Control, Regression Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review