Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 337

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

High Performance Liquid Chromatography Method for Rapid and Accurate Determination of Homocysteine in Plasma and Serum

Open access
Vester, Birte, Rasmussen, K. · 1991 · Clinical Chemistry and Laboratory Medicine

Abstract

Determination of homocysteine in plasma or serum for evaluation of cobalamin and folate deficiency is becoming an important diagnostic procedure. Accurate, rapid and low cost methods for measuring homocysteine are therefore required. We have improved an HPLC method and made it suitable for clinical application. The more important changes are the addition of an internal standard, mercaptopropionylglycine, and the use of a plasma/serum based calibration material. The method consists of the following steps: reduction of the sample with tri-n-butylphosphine, precipitation of proteins, derivatisation with ammonium 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate, and HPLC separation followed by fluorescence detection. The linearity of the assays is established and the coefficient of variation is 3.0%. Stability studies show that blood samples must be cooled or centrifuged immediately after venipuncture. The method is useful for evaluation of cobalamin or folate deficiency, especially in patients with normal or moderately depressed cobalamin or folate concentrations in blood.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.1991.29.9.549

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 337

Metadata

Authors
Vester, B., & Rasmussen, K.
Venue
Clinical Chemistry and Laboratory Medicine
Published
1991
Volume
29
Issue
9
Pages
549-54
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2115122255
Cited by
337
References
7
FWCI
2.38
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Performance Liquid Chromatography Method for Rapid and Accurate Determination of Homocysteine in Plasma and Serum. https://app.cochat.ai/papers/10.1515/cclm.1991.29.9.549
The paper
Vester, B., & Rasmussen, K. (1991). High Performance Liquid Chromatography Method for Rapid and Accurate Determination of Homocysteine in Plasma and Serum. Clinical Chemistry and Laboratory Medicine. https://doi.org/10.1515/cclm.1991.29.9.549

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.