CoChat

Influence of in vivo Hemoglobin Carbamylation on HbA1c Measurements by Various Methods

Chachou, Abdelhalim, Randoux, Christine, Millart, Hervé, Chanard, Jacques, Gillery, Philippe · 2000 · cclm
Cited by 52

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Increased carbamylated hemoglobin formed in erythrocytes during uremia may interfere with Hba 1c assays, but few studies compared directly both parameters. We measured carbamylated hemoglobin by HPLC in 45 non-diabetic uremic patients (16 with acute and two with chronic renal failure, 27 with transplant recipients) as 57.8 ± 22.3 μg carbamylvaline/g Hb (mean ± standard deviation) vs. 31.6 ± 5.1 in 15 controls (+83%, p < 0.001). In these samples, HbA 1c was evaluated by three ion-exchange HPLC methods, 1: Diamat (BioRad), 2: A1c2.2 (Tosoh) and 3: HA8140 (Menarini), and one immunoassay method (Tinaquant II Roche). Whichever the method, mean HbA 1c values obtained increased in patients with high (> 60 μg carbamylvaline/g Hb) vs. low (< 45) carbamylated hemoglobin values (+0.08 to 0.25% of total Hb), but differences were not significant. Minor peaks on the chromatograms were however increased in parallel to carbamylated hemoglobin. HbA 1c values over 6% were found in 4, 1, 2 and 0 samples, with HPLC 1, 2, 3 and immunoassay, respectively. Fructosamine values were not significantly altered. Our results show that Hb adducts, whether due to carbamylation or to other chemical reactions, interfere to a variable extent with different HbA 1c assay methods, and confirm that HbA 1c values should be interpreted with caution in uremic patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2000.046

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 52

Metadata

Authors
Chachou, A., Randoux, C., Millart, H., Chanard, J., & Gillery, P.
Venue
cclm
Published
2000-04-30
Volume
38
Issue
4
Pages
321-326
ISSN
1434-6621 (ISSN-L)
OpenAlex
W2033658265
Cited by
52
References
2
FWCI
1.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of in vivo Hemoglobin Carbamylation on HbA1c Measurements by Various Methods. https://app.cochat.ai/papers/10.1515/cclm.2000.046
The paper
Chachou, A., Randoux, C., Millart, H., Chanard, J., & Gillery, P. (2000). Influence of in vivo Hemoglobin Carbamylation on HbA1c Measurements by Various Methods. cclm. https://doi.org/10.1515/cclm.2000.046

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.