CoChat

Determination of Serum Cortisol by Isotope-Dilution Liquid-Chromatography Electrospray Ionization Tandem Mass Spectrometry with On-line Extraction

Open access
Vogeser, Michael, Briegel, Josef, Jacob, Karl · 2001 · Clinical Chemistry and Laboratory Medicine
Cited by 50

The DOI matches its Crossref record.

Abstract

A liquid chromatographic-mass spectrometric method for the determination of cortisol in serum using atmospheric pressure electrospray ionization and tandem mass spectrometry is described. During sample preparation, 150 microl of serum were deproteinized with methanol/zinc sulfate followed by on-line solid phase extraction employing column switching. Tri-deuterated cortisol was used as the internal standard. The following transitions were monitored: cortisol, 363>309 m/z; d3-cortisol, 366>312 m/z. The total run-time was 5 minutes. The method proved linear (0-500 microg/l; r=0.999), precise (total coefficient of variation between 5.0% and 3.2% at a mean cortisol concentration of 15.1 microg/l and 269 microg/l, respectively; n=16) and specific with regard to relevant endogenous and exogenous steroids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2001.151

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Vogeser, M., Briegel, J., & Jacob, K.
Venue
Clinical Chemistry and Laboratory Medicine
Published
2001-01-23
Volume
39
Issue
10
Pages
944-7
ISSN
1434-6621 (ISSN-L)
OpenAlex
W2143294886
Cited by
50
References
0
FWCI
1.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.