CoChat

Quality Assurance for Cerebrospinal Fluid Protein Analysis: International Consensus by an Internet-Based Group Discussion

Reiber, H., Thompson, E. J., Grimsley, G., Bernardi, G., Adam, P., Almeida, S. Monteiro de, Fredman, P., Keir, G., Lammers, M., Liblau, R., Menna-Barreto, M., Sá, M. J., Seres, E., Sindic, C. J. M., Teelken, A., Trendelenburg, C., Trojano, M., Antwerpen, M. van, Verbeek, M. M. · 2003 · Clinical Chemistry and Laboratory Medicine
Cited by 73

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A group of neurologists and clinical neurochemists representing twelve countries worked towards a consensus on laboratory techniques to improve the quality of analysis and interpretation of cerebrospinal fluid (CSF) proteins. Consensus was approached via a virtual Lotus Notes-based TeamRoom. This new approach respecting multicultural differences, common views, and minority opinions, is available in http://www.teamspace.net/ CSF, presenting the implicit, complementary version of this explicit, printed consensus. Three key recommendations were made: CSF and (appropriately diluted) serum samples should be analyzed together in one analytical run, i.e., with reference to the same calibration curve. Results are evaluated as CSF/serum quotients, taking into account the non-linear, hyperbolic relation between immunoglobulin (Ig)- and albumin-quotients rather than using the linear IgG index or IgG synthesis rate. Controls should include materials with values within the reference ranges (IgM: 0.5-1.5 mg/l; IgA: 1-3 mg/l; IgG: 10-30 mg/l and albumin: 100-300 mg/l). The physiological, methodological and clinical significance of CSF/serum quotients is reviewed. We confirmed the previous consensus on oligoclonal IgG, in particular the usefulness of the five typical interpretation patterns. The group compared current external and internal quality assurance schemes and encouraged all members to maintain national or local traditions. Values for acceptable imprecision in the CSF quality assurance are proposed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2003.053

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Reiber, H., Thompson, E. J., Grimsley, G., Bernardi, G., Adam, P., Almeida, S. M. D., Fredman, P., Keir, G., Lammers, M., Liblau, R., Menna-Barreto, M., Sá, M. J., Seres, E., Sindic, C. J. M., Teelken, A., Trendelenburg, C., Trojano, M., Antwerpen, M. V., & Verbeek, M. M.
Venue
Clinical Chemistry and Laboratory Medicine
Published
2003-01-24
Volume
41
Issue
3
Pages
331-7
ISSN
1434-6621 (ISSN-L)
OpenAlex
W2099084548
Cited by
73
References
1
FWCI
4.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.