Cited by 36Clinical Laboratory Practices and Quality ControlAnalytical chemistry methods developmentVarious Chemistry Research Topics

Evaluation of a new generation of plastic evacuated blood-collection tubes in clinical chemistry, therapeutic drug monitoring, hormone and trace metal analysis

Boeynaems, Jean-Marie, Leener, Anne De, Dessars, Barbara, Villa-Lobos, Hector Rodriguez, Aubry, Jean-Claude, Cotton, Frédéric, Thiry, Philippe·2004·Clinical Chemistry and Laboratory Medicine (CCLM)

Abstract

Polyethylene terephthalate (PET) tubes have several advantages over glass tubes: they are unbreakable, lighter and more easily disposed of. Despite a steady increase in their use and an expansion of the range of available tubes, few studies validating their use have been published in the literature. This paper describes the various studies that have been performed to compare VENOJECT glass, VENOSAFE PET and VENOSAFE PET/heparin tubes for the assay of a panel of analytes in routine clinical chemistry, immunochemistry, hormone and tumor marker analysis and trace metal determination. These studies demonstrate that VENOSAFE PET tubes are a suitable alternative to glass tubes.

Integrity signals

Registry

Crossref · 10.1515/cclm.2004.013

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Boeynaems, J.-M., Leener, A. D., Dessars, B., Villa-Lobos, H. R., Aubry, J.-C., Cotton, F., & Thiry, P.
Affiliations
Université Libre de Bruxelles (BE)
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2004-01-16
Volume
42
Issue
1
Pages
67-71
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W1993391036
Cited by
36
References
5
Citations by year
2026: 1 · 2023: 2 · 2022: 3 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 1 · 2016: 3 · 2014: 4 · 2012: 2
FWCI
1.46
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Various Chemistry Research Topics
Keywords
clinical chemistry analytes, therapeutic drug monitoring, hormone analysis, trace metal analysis, immunochemistry
MeSH terms
Blood Specimen Collection, Glass, Heparin, Hormones, Humans, Metals, Polyethylene Terephthalates, Water, Drug Monitoring, Clinical Chemistry Tests

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review