CoChat

First WHO/IFCC International Reference Reagent for Lipoprotein(a) for Immunoassay – Lp(a) SRM 2B

Dati, Francesco, Tate, Jillian R., Marcovina, Santica M., Steinmetz, Armin · 2004 · Clinical Chemistry and Laboratory Medicine (CCLM)
Cited by 124

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Lipoprotein(a) is an important predictor of cardiovascular disease risk. The lack of internationally accepted standardization has impeded the broad application of this lipoprotein in laboratory medicine. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), through its Working Group on Lipoprotein(a) and together with research institutions and several diagnostic companies, have succeeded in developing an international reference material that is intended for the transfer of a lipoprotein(a) concentration to manufacturers' master calibrators. IFCC SRM 2B has recently been accepted by the WHO Expert Committee on Biological Standardization as the ‘First WHO/IFCC International Reference Reagent for Lipoprotein(a) for Immunoassay’. The assigned unitage of 0.1071 nanomoles of lipoprotein(a) per vial is traceable to the consensus reference method for lipoprotein( a) and will enable conformity by diagnostic companies to the European Union's Directive on In vitro Diagnostic Medical Devices for the metrological traceability of calibrator materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2004.114

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 124

Metadata

Authors
Dati, F., Tate, J. R., Marcovina, S. M., & Steinmetz, A.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2004-01-07
Volume
42
Issue
6
Pages
670-6
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2009191878
Cited by
124
References
1
FWCI
1.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: First WHO/IFCC International Reference Reagent for Lipoprotein(a) for Immunoassay – Lp(a) SRM 2B. https://app.cochat.ai/papers/10.1515/cclm.2004.114
The paper
Dati, F., Tate, J. R., Marcovina, S. M., & Steinmetz, A. (2004). First WHO/IFCC International Reference Reagent for Lipoprotein(a) for Immunoassay – Lp(a) SRM 2B. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm.2004.114

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.