The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Errors in clinical laboratories or errors in laboratory medicine?
Abstract
Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46–68.2% of total errors), while a high error rate (18.5–47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called “laboratory errors”, although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term “laboratory error” and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes in pre- and post-examination steps must be minimized to guarantee the total quality of laboratory services.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
To Err Is Human: Building a Safer Health System
(2000) · National Academies Press eBooks · doi:10.17226/9728 · Cited by 14,044
Five Years After To Err Is Human: What Have We Learned?
Leape, L. L., & Berwick, D. M. (2005) · JAMA · doi:10.1001/jama.293.19.2384 · Cited by 1,250
(2000) · Psychology Press eBooks · doi:10.4324/9781410605795 · Cited by 915
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Self-citationMistakes in a stat laboratory: types and frequency
Plebani, M., & Carraro, P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1348 · Cited by 572
Self-citationWhy is the laboratory an afterthought for managed care organizations?
Forsman, R. W. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.5.813 · Cited by 387
Current and Emerging Infectious Risks of Blood Transfusions
Busch, M. P., Kleinman, S. H., & Nemo, G. J. (2003) · JAMA · doi:10.1001/jama.289.8.959 · Cited by 334
Techniques to Improve Physicians' Use of Diagnostic Tests: A New Conceptual Framework
Solomon, D. H., Hashimoto, H., Daltroy, L., & Liang, M. H. (1998) · JAMA · doi:10.1001/jama.280.23.2020 · Cited by 321
Improving Patient Safety — Five Years after the IOM Report
Altman, D. E., Clancy, C., & Blendon, R. J. (2004) · New England Journal of Medicine · doi:10.1056/nejmp048243 · Cited by 233
Errors in Laboratory Medicine: Practical Lessons to Improve Patient Safety
Howanitz, P. J. (2005) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2005-129-1252-eilmpl · Cited by 218
A Survey of the Accuracy of Chemical Analyses in Clinical Laboratories
Belk, W. P., & Sunderman, F. W. (1947) · American Journal of Clinical Pathology · doi:10.1093/ajcp/17.11.853 · Cited by 180
Medical errors: impact on clinical laboratories and other critical areas
Kalra, J. (2004) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.08.009 · Cited by 168
Tartrate-resistant Acid Phosphatase Isoform 5b as Serum Marker for Osteoclastic Activity
Janckila, A. J., Takahashi, K., Sun, S. Z., & Yam, L. T. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.1.74 · Cited by 158
Classifying Laboratory Incident Reports to Identify Problems That Jeopardize Patient Safety
Shojania, K. G., Hamill, T. R., Kim, P. S., Ng, M. V. L., & Astion, M. L. (2003) · American Journal of Clinical Pathology · doi:10.1309/8u5d0ma6mfh2fg19 · Cited by 155
Ismail, A. A., Walker, P. L., Barth, J. H., Lewandowski, K. C., Jones, R., & Burr, W. A. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.11.2023 · Cited by 150
Marks, V. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.11.2008 · Cited by 146
The evolution of the reference value concept
Gräsbeck, R. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.118 · Cited by 142
Interferences in Immunoassay—Still a Threat
Kricka, L. J. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.8.1037 · Cited by 132
Immunometric Assay Interference
Bjerner, J., Nustad, K., Norum, L. F., Olsen, K. H., & Børmer, O. P. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.4.613 · Cited by 128
Jones, B. A., Calam, R. R., & Howanitz, P. J. (1997) · PubMed · Cited by 128
Ricós, C., García-Victoria, M., & de la Fuente, B. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.100 · Cited by 126
Errors, mistakes, blunders, outliers, or unacceptable results: how many?
Witte, D. L., VanNess, S. A., Angstadt, D. S., & Pennell, B. J. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1352 · Cited by 112
Laposata, M. E., Laposata, M., Cott, E. M. V., Buchner, D. S., Kashalo, M. S., & Dighe, A. S. (2004) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2004-128-1424-psoalm · Cited by 111
Overview of the role of molecular methods in the diagnosis of malignant lymphomas.
Medeiros, L., & Carr, J. (1999) · Archives of Pathology & Laboratory Medicine · doi:10.1043/0003-9985(1999)123<1145:ooa>2.0.co;2 · Cited by 110
Renner, S. W., Howanitz, P. J., & Bachner, P. (1993) · PubMed · Cited by 102
Problems in Laboratory Testing in Primary Care
Nutting, P. A. (1996) · JAMA · doi:10.1001/jama.1996.03530320059035 · Cited by 100
Influence of short-term venous stasis on clinical chemistry testing
Lippi, G., Salvagno, G. L., Montagnana, M., Brocco, G., & Guidi, G. C. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.146 · Cited by 81
Stroobants, A. K., Goldschmidt, H. M. J., & Plebani, M. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00181-5 · Cited by 78
Self-citationUse of computer terminals on wards to access emergency test results: a retrospective audit
Kilpatrick, E. S., & Holding, S. (2001) · BMJ · doi:10.1136/bmj.322.7294.1101 · Cited by 74
Quality Assessment of Interpretative Commenting in Clinical Chemistry
Lim, E. M., Sikaris, K. A., Gill, J., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.024877 · Cited by 74
Lippi, G., Brocco, G., Franchini, M., Schena, F., & Guidi, G. C. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.110 · Cited by 74
Charting the course of medical laboratories in a changing environment
Plebani, M. (2002) · Clinica Chimica Acta · doi:10.1016/s0009-8981(02)00028-1 · Cited by 73
Self-citationLapworth, R., & Teal, T. K. (1994) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329403100113 · Cited by 65
The laboratory is a key partner in assuring patient safety
Stanković, A. K. (2004) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2004.05.017 · Cited by 59
Clinical interpretation of reference intervals and reference limits. A plea for assay harmonization
Klee, G. G. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.127 · Cited by 53
Towards quality specifications in extra-analytical phases of laboratory activity
Plebani, M. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.099 · Cited by 51
Self-citationEvaluation of LabRespond, a New Automated Validation System for Clinical Laboratory Test Results
Oosterhuis, W. P., Ulenkate, H. J. L. M., & Goldschmidt, H. M. J. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.11.1811 · Cited by 51
Identification of preanalytical mistakes in the stat section of the clinical laboratory
Ruiz, A. R., Múñoz, M., Ramos, J. R., Campos, A., & Ramírez, G. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.168 · Cited by 46
Valenstein, P. N., & Meier, F. A. (1999) · Archives of Pathology & Laboratory Medicine · doi:10.5858/1999-123-1145-ooa · Cited by 45
Conveying the Importance of the Preanalytical Phase
Young, D. S. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.133 · Cited by 37
Reference values: from philosophy to a tool for laboratory medicine
Henny, J., & Petersen, P. H. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.117 · Cited by 37
Steindel, S. J., Howanitz, P. J., & Renner, S. W. (1996) · PubMed · Cited by 33
Ordering accuracy. A College of American Pathologists Q-Probes study of 577 institutions.
Valenstein, P. N., & Howanitz, P. J. (1995) · PubMed · Cited by 26
Is it safe to have a laboratory test?
Boone, D. J. (2004) · Accreditation and Quality Assurance · doi:10.1007/s00769-004-0855-5 · Cited by 23
Reference Intervals: Are Interlaboratory Differences Appropriate?
Zardo, L., Secchiero, S., Sciacovelli, L., Bonvicini, P., & Plebani, M. (1999) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1999.165 · Cited by 21
Self-citationThe Generation of Narrative Interpretations in Laboratory Medicine
Kratz, A. F., Soderberg, B. L., Szczepiorkowski, Z. M., et al. (2001) · Pathology Patterns Reviews · doi:10.1309/f9b6-33hk-8b0b-8lnm · Cited by 20
Blumenthal, D. (1997) · PubMed · Cited by 19
Patient Satisfaction in Phlebotomy: A College of American Pathologists′ Q-Probes Study
Dale, J. C., & Howanitz, P. J. (1996) · Laboratory Medicine · doi:10.1093/labmed/27.3.188 · Cited by 16
Cited by
A consensus protocol for the standardization of cerebrospinal fluid collection and biobanking
Teunissen, C. E., Petzold, A., Bennett, J. L., Berven, F. S., Brundin, L., Comabella, M., Franciotta, D., Frederiksen, J. L., Fleming, J. O., Furlan, R., et al. (2009) · Neurology · doi:10.1212/wnl.0b013e3181c47cc2 · Cited by 845
Errors in a Stat Laboratory: Types and Frequencies 10 Years Later
Carraro, P., & Plebani, M. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.088344 · Cited by 670
Self-citationThe detection and prevention of errors in laboratory medicine
Plebani, M. (2010) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2009.009222 · Cited by 479
Self-citationHaemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., & Plebani, M. (2008) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2008.170 · Cited by 466
Self-citationCognitive and System Factors Contributing to Diagnostic Errors in Radiology
Lee, C. S., Nagy, P. G., Weaver, S. J., & Newman-Toker, D. E. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.10375 · Cited by 415
Metadata
- Authors
- Plebani, M.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2006-01-01
- Volume
- 44
- Issue
- 6
- Pages
- 750-9
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2053682685
- Cited by
- 734
- References
- 48
- FWCI
- 14.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.