Influence of the needle bore size used for collecting venous blood samples on routine clinical chemistry testing
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Despite remarkable advances in technology and laboratory automation, results of laboratory testing still suffer from a high degree of preanalytical variability. Although there is no definitive evidence, the use of small-gauge needles for venipuncture is usually discouraged to reduce the chance of producing unsuitable specimens. METHODS: The purpose of this investigation was to assess the influence of the needle size used to collect venous blood on the measurement of 14 common analytes, including free hemoglobin, the most representative enzymes, protein-bound substances and electrolytes. Results for venous blood samples collected from 20 fasting voluntary physicians using either a 23- (0.60 mmx19 mm) or 25-gauge-needle (0.50 mmx19 mm) butterfly devices with polyvinyl chloride tubing (1.40 mmx300 mm) were compared with reference specimens collected using a 21-gauge-needle (0.80 mmx19 mm) butterfly device with polyvinyl chloride tubing (1.40 mmx300 mm). RESULTS: All means for paired samples collected using the smaller needles did not differ significantly from the reference specimen by paired Student's t-test analysis. Passing-Bablok regression analysis and Pearson's or Spearman (creatine kinase, aspartate aminotransferase, alanine aminotransferase and chloride) correlation were acceptable for most of the analyses, although a lower correlation coefficient was observed for electrolytes. In addition, when expressed as a percentage of the mean for paired samples, the s(y,x) value exceeded the desirable bias for free hemoglobin, glucose, lactate dehydrogenase, aspartate aminotransferase, sodium, chloride, calcium and magnesium (in samples collected using both 23 G and 25 G needles) and potassium (in samples collected using a 25 G needle). Although Bland-Altman plot analysis and +/-1.96 SD agreement intervals for the set of differences between values was acceptable overall, the bias was rather broad for free hemoglobin and several critical electrolytes (calcium, chloride, potassium, sodium), exceeding the respective limits for desirable bias. CONCLUSIONS: The results of our investigation indicate that 23 G needles, if handled correctly, will not introduce any statistically or clinically significant error to the measurement results compared to a 21 G needle. For the 25 G needle, we observed increased variability for potassium compared to a 23 G needle. Small-bore needles of 25 G or less cannot be universally recommended when collecting venous blood for clinical chemistry testing and should be reserved for selected circumstances, such as in patients with problematical venous accesses and newborns. In such cases, however, the bias introduced by the use of smaller needles should always be taken into consideration when interpreting test results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Effect of specimen collection on routine coagulation assays and D-dimer measurement
Lippi, G., & Guidi, G. C. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.036244 · Cited by 39 · cited 1×
“Nevertheless, we have already demonstrated that when a standardized technique and identical materials are used for collecting blood specimens during separate sequential phlebotomies on the same patient, the bias recorded can be almost completely attributed to the single variable modified between the first venipuncture…”
MethodSelf-citation
Cited by
New guidelines for hemorheological laboratory techniques
Baskurt, O. K., Boynard, M., Cokelet, G. C., Connes, P., Cooke, B. M., Forconi, S., Liao, F., Hardeman, M. R., Jung, F., Meiselman, H. J., et al. (2009) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-2009-1202 · Cited by 514
Impact of blood collection devices on clinical chemistry assays
Bowen, R. A. R., Hortin, G. L., Csako, G., Otañez, O. H., & Remaley, A. T. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.10.001 · Cited by 240
“Those authors recommended that small-bore needles be reserved for neonates and patients with poor venous access [20].”
BackgroundMethodInfluentialLima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Self-citationPhlebotomy, a bridge between laboratory and patient
Ialongo, C., & Bernardini, S. (2016) · Biochemia Medica · doi:10.11613/bm.2016.002 · Cited by 97
“In this regard there are two major mechanical causes related to phlebotomy procedure: the shear stress on red blood cells flowing through a small bore needle which causes haemolysis and the needle probing of the bloodstream which damages the tissue neighbouring the venipuncture site (103-105).”
Seimiya, M., Yoshida, T., Sawabe, Y., Sogawa, K., Umemura, H., Matsushita, K., & Nomura, F. (2010) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2010.06.014 · Cited by 28
Mouser, A., Uettwiller-Geiger, D., Plokhoy, E., Berube, J., Ahuja, A. J., & Stankovic, A. K. (2017) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2017.023564 · Cited by 14
Padoan, A., Sirini, S., Mazzone, R., Mesiti, C., Grillo, C., Meyer, B., & Plebani, M. (2020) · Clinica Chimica Acta · doi:10.1016/j.cca.2019.10.019 · Cited by 8
Assessing phlebotomy device preference and specimen quality in an oncology outpatient clinic
Merrill, V. D., Ward, M. D., Diaz-McNair, J., Pickett, E. A., Duh, S.-H., & Christenson, R. H. (2022) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfab109 · Cited by 7
“Pediatric samples were also shown to have similar quality attributes as compared to a comparable blood collection system (7, 12).”
BackgroundResultInfluentialGiussani, M., Sirini, S., Padoan, A., Bonini, C., Meyer, B., & Morelli, D. (2024) · European Journal of Oncology Nursing · doi:10.1016/j.ejon.2024.102680
Metadata
- Authors
- Lippi, G., Salvagno, G. L., Montagnana, M., Brocco, G., & Cesare Guidi, G.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2006-01-01
- Volume
- 44
- Issue
- 8
- Pages
- 1009-14
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2117961843
- Cited by
- 56
- References
- 3
- FWCI
- 0.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.