Causes, consequences, detection, and prevention of identification errors in laboratory diagnostics

Open access
Lippi, Giuseppe, Blanckaert, Norbert, Bonini, Pierangelo, Green, Sol, Kitchen, Steve, Palicka, Vladimir, Vassault, Anne J., Mattiuzzi, Camilla, Plebani, Mario·2009·Clinical Chemistry and Laboratory Medicine

Abstract

Laboratory diagnostics, a pivotal part of clinical decision making, is no safer than other areas of healthcare, with most errors occurring in the manually intensive preanalytical process. Patient misidentification errors are potentially associated with the worst clinical outcome due to the potential for misdiagnosis and inappropriate therapy. While it is misleadingly assumed that identification errors occur at a low frequency in clinical laboratories, misidentification of general laboratory specimens is around 1% and can produce serious harm to patients, when not promptly detected. This article focuses on this challenging issue, providing an overview on the prevalence and leading causes of identification errors, analyzing the potential adverse consequences, and providing tentative guidelines for detection and prevention based on direct-positive identification, the use of information technology for data entry, automated systems for patient identification and specimen labeling, two or more identifiers during sample collection and delta check technology to identify significant variance of results from historical values. Once misidentification is detected, rejection and recollection is the most suitable approach to manage the specimen. Clin Chem Lab Med 2009;47:143–53.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2009.045

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 167

Metadata

Authors
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., Mattiuzzi, C., & Plebani, M.
Venue
Clinical Chemistry and Laboratory Medicine
Published
2009-01-01
Volume
47
Issue
2
Pages
143-53
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2057104422
Cited by
167
References
3
FWCI
5.83
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Causes, consequences, detection, and prevention of identification errors in laboratory diagnostics. https://app.cochat.ai/papers/10.1515/cclm.2009.045
The paper
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., Mattiuzzi, C., & Plebani, M. (2009). Causes, consequences, detection, and prevention of identification errors in laboratory diagnostics. Clinical Chemistry and Laboratory Medicine. https://doi.org/10.1515/cclm.2009.045

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.