The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: a new tool to assess the acceptability of intensive care unit testing
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Most estimates of biologic variation (s b) are based on periodically acquiring and storing specimens, followed by analysis within a single analytic run. We demonstrate for many intensive care unit (ICU) tests, only patient results need be statistically analyzed to provide reliable estimates of s b. Methods: Over 11 months, approximately 28,000 blood gas measurements (including electrolyte panels and glucose) were performed on one of two Radiometer ABL800 FLEX analyzers (Radiometer, Copenhagen, Denmark) from 1676 ICU patients. We tabulated the measurements of paired intra-patient blood samples drawn within 24 h of each other. After removal of outliers, we calculated the standard deviations of duplicates (SDD) of the intra-patient pairs grouped in 2-h intervals: 0–2 h, 2–4 h, 4–6 h, … 20–22 h and 22–24 h. The SDDs were then regressed against the time intervals of 2–14 h; extrapolation to zero time represents the sum of s b and short-term analytic variation (s a). Results: Substitution of experimentally derived analytic error permitted the calculation of coefficient of variation (biologic) (CV b) (100 s b/mean): pH, 0.3%; pCO 2, 5.7%; pO 2, 13%; Na+, 0.6%; K+, 4.8%; Cl–, 0.8%; HCO 3 –, 3.2%; iCa++, 2.4%; and glucose, 10.3%. The CV b of the electrolytes very closely matches the lowest estimates obtained in the usual manner. Conclusions: Derivation of the ratio of biologic to analytic variation indicates that the ABL800 is extremely suitable for ICU testing. This analysis should be extended to other point of care instrument systems. Clin Chem Lab Med 2010;48:1447–54.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
Analytical performance characteristics should be judged against objective quality specifications
Fraser, C. G., & Petersen, P. H. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.3.321 · Cited by 194
Cited by
Indirect methods for reference interval determination – review and recommendations
Jones, G. R. D., Haeckel, R., Loh, T. P., Sikaris, K., Streichert, T., Katayev, A., Barth, J. H., & Ozarda, Y. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0073 · Cited by 349
Fraser, C. G. (2012) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.733 · Cited by 286
Influence of a regular, standardized meal on clinical chemistry analytes
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Gelati, M., Montagnana, M., Danese, E., Picheth, G., & Guidi, G. C. (2012) · Annals of Laboratory Medicine · doi:10.3343/alm.2012.32.4.250 · Cited by 63
Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.026 · Cited by 33
“Obviously the quality specifi cations derived from biological variation are considered both very important and useful in the daily practice by the quality managers of the medical laboratories (13,29,30).”
BackgroundLima-Oliveira, G., Lippi, G., Salvagno, G. L., Brocco, G., Gaino, S., Dima, F., Volaski, W., Rego, F. G., Picheth, G., & Guidi, G. C. (2014) · Biopreservation and Biobanking · doi:10.1089/bio.2013.0043 · Cited by 22
Metadata
- Authors
- Cembrowski, G. S., Tran, D. V., & Higgins, T. N.
- Venue
- cclm
- Publisher
- Walter de Gruyter GmbH
- Published
- 2010-08-18
- Volume
- 48
- Issue
- 10
- Pages
- 1447-1454
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W1999247754
- Cited by
- 30
- References
- 2
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.