Absolute reliability and concurrent validity of hand held dynamometry and isokinetic dynamometry in the hip, knee and ankle joint: systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
The purpose of the study is to establish absolute reliability and concurrent validity between hand-held dynamometers (HHDs) and isokinetic dynamometers (IDs) in lower extremity peak torque assessment. Medline, Embase, CINAHL databases were searched for studies related to psychometric properties in muscle dynamometry. Studies considering standard error of measurement SEM (%) or limit of agreement LOA (%) expressed as percentage of the mean, were considered to establish absolute reliability while studies using intra-class correlation coefficient (ICC) were considered to establish concurrent validity between dynamometers. In total, 17 studies were included in the meta-analysis. The COSMIN checklist classified them between fair and poor. Using HHDs, knee extension LOA (%) was 33.59%, 95% confidence interval (CI) 23.91 to 43.26 and ankle plantar flexion LOA (%) was 48.87%, CI 35.19 to 62.56. Using IDs, hip adduction and extension; knee flexion and extension; and ankle dorsiflexion showed LOA (%) under 15%. Lower hip, knee, and ankle LOA (%) were obtained using an ID compared to HHD. ICC between devices ranged between 0.62, CI (0.37 to 0.87) for ankle dorsiflexion to 0.94, IC (0.91to 0.98) for hip adduction. Very high correlation were found for hip adductors and hip flexors and moderate correlations for knee flexors/extensors and ankle plantar/dorsiflexors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164 · cited 1×
“The reporting of this systematic review is based on Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines [18].”
MethodQuality criteria were proposed for measurement properties of health status questionnaires
Terwee, C. B., Bot, S. D. M., de Boer, M. R., van der Windt, D. A. W. M., Knol, D. L., Dekker, J., Bouter, L. M., & de Vet, H. C. W. (2007) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.03.012 · Cited by 10,764 · cited 2×
“To maintain the independence of administrations, there should normally be at least seven days between measurements [37].”
BackgroundLiberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00136 · Cited by 10,349
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635 · cited 2×
“This is problematic in that muscle force improvements or deteriorations < 15% are still considered clinically relevant but would not be detected by HDDs [40].”
BackgroundStatistical methods for health care research
Munro, B. H. (1986) · Medical Entomology and Zoology · Cited by 2,265
Terwee, C. B., Mokkink, L. B., Knol, D. L., Ostelo, R. W. J. G., Bouter, L. M., & de Vet, H. C. W. (2012) · Quality of Life Research · doi:10.1007/s11136-011-9960-1 · Cited by 1,978 · cited 3×
“It is a recognized valid tool for evaluating the psychometric properties of health instruments [22].”
MethodInfluentialValovich-mcLeod, T. C., Shultz, S. J., Gansneder, B. M., Perrin, D. H., & Drouin, J. M. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0933-0 · Cited by 839
Hand‐held Dynamometry Correlation With the Gold Standard Isokinetic Dynamometry: A Systematic Review
Stark, T., Walker, B., Phillips, J. K., Fejer, R., & Beck, R. (2011) · PM&R · doi:10.1016/j.pmrj.2010.10.025 · Cited by 816 · cited 1×
“While the psychometric properties of these devices have been investigated in different contexts using different models, joints and conditions, the resulting information is fragmented and difficult to comprehensively understand [4-8].”
BackgroundMentiplay, B. F., Perraton, L. G., Bower, K. J., Adair, B., Pua, Y.-H., Williams, G. P., McGaw, R., & Clark, R. A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140822 · Cited by 601 · cited 14×
“One study [26] simultaneously assessed absolute reliability of the Lafayette and Hoggan Health HHDs in the hip, knee, and ankle.”
BackgroundMethodInfluentialStratford, P. W., & Goldsmith, C. H. (1997) · Physical Therapy · doi:10.1093/ptj/77.7.745 · Cited by 455
Cited by
Pizol, G. Z., Ferro Moura Franco, K., Cristiane Miyamoto, G., & Maria Nunes Cabral, C. (2023) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-023-06920-x · Cited by 9
Metadata
- Authors
- Chamorro, C., Armijo-Olivo, S., De la Fuente, C., Fuentes, J., & Javier Chirosa, L.
- Venue
- Open Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2017-10-01
- Volume
- 12
- Issue
- 1
- Pages
- 359-375
- ISSN
- 1895-1058 (ISSN-L)
- 2391-5463
- OpenAlex
- W2765605718
- Cited by
- 195
- References
- 39
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.