Absolute reliability and concurrent validity of hand held dynamometry and isokinetic dynamometry in the hip, knee and ankle joint: systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
The purpose of the study is to establish absolute reliability and concurrent validity between hand-held dynamometers (HHDs) and isokinetic dynamometers (IDs) in lower extremity peak torque assessment. Medline, Embase, CINAHL databases were searched for studies related to psychometric properties in muscle dynamometry. Studies considering standard error of measurement SEM (%) or limit of agreement LOA (%) expressed as percentage of the mean, were considered to establish absolute reliability while studies using intra-class correlation coefficient (ICC) were considered to establish concurrent validity between dynamometers. In total, 17 studies were included in the meta-analysis. The COSMIN checklist classified them between fair and poor. Using HHDs, knee extension LOA (%) was 33.59%, 95% confidence interval (CI) 23.91 to 43.26 and ankle plantar flexion LOA (%) was 48.87%, CI 35.19 to 62.56. Using IDs, hip adduction and extension; knee flexion and extension; and ankle dorsiflexion showed LOA (%) under 15%. Lower hip, knee, and ankle LOA (%) were obtained using an ID compared to HHD. ICC between devices ranged between 0.62, CI (0.37 to 0.87) for ankle dorsiflexion to 0.94, IC (0.91to 0.98) for hip adduction. Very high correlation were found for hip adductors and hip flexors and moderate correlations for knee flexors/extensors and ankle plantar/dorsiflexors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164 · cited 1×
“The reporting of this systematic review is based on Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines [18].”
MethodQuality criteria were proposed for measurement properties of health status questionnaires
Terwee, C. B., Bot, S. D. M., de Boer, M. R., van der Windt, D. A. W. M., Knol, D. L., Dekker, J., Bouter, L. M., & de Vet, H. C. W. (2007) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.03.012 · Cited by 10,764 · cited 2×
“To maintain the independence of administrations, there should normally be at least seven days between measurements [37].”
BackgroundLiberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00136 · Cited by 10,349
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635 · cited 2×
“This is problematic in that muscle force improvements or deteriorations < 15% are still considered clinically relevant but would not be detected by HDDs [40].”
BackgroundStatistical methods for health care research
Munro, B. H. (1986) · Medical Entomology and Zoology · Cited by 2,265
Terwee, C. B., Mokkink, L. B., Knol, D. L., Ostelo, R. W. J. G., Bouter, L. M., & de Vet, H. C. W. (2012) · Quality of Life Research · doi:10.1007/s11136-011-9960-1 · Cited by 1,978 · cited 3×
“It is a recognized valid tool for evaluating the psychometric properties of health instruments [22].”
MethodInfluentialValovich-mcLeod, T. C., Shultz, S. J., Gansneder, B. M., Perrin, D. H., & Drouin, J. M. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0933-0 · Cited by 839
Hand‐held Dynamometry Correlation With the Gold Standard Isokinetic Dynamometry: A Systematic Review
Stark, T., Walker, B., Phillips, J. K., Fejer, R., & Beck, R. (2011) · PM&R · doi:10.1016/j.pmrj.2010.10.025 · Cited by 816 · cited 1×
“While the psychometric properties of these devices have been investigated in different contexts using different models, joints and conditions, the resulting information is fragmented and difficult to comprehensively understand [4-8].”
BackgroundMentiplay, B. F., Perraton, L. G., Bower, K. J., Adair, B., Pua, Y.-H., Williams, G. P., McGaw, R., & Clark, R. A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140822 · Cited by 601 · cited 14×
“One study [26] simultaneously assessed absolute reliability of the Lafayette and Hoggan Health HHDs in the hip, knee, and ankle.”
BackgroundMethodInfluentialStratford, P. W., & Goldsmith, C. H. (1997) · Physical Therapy · doi:10.1093/ptj/77.7.745 · Cited by 455
Nevill, A. M., & Atkinson, G. (1997) · British Journal of Sports Medicine · doi:10.1136/bjsm.31.4.314 · Cited by 317
Daniels and Worthingham's Muscle Testing: Techniques of Manual Examination and Performance Testing
Daniels, L., Worthingham, C. A., Hislop, H. J., Avers, D., & Brown, M. (2013) · Medical Entomology and Zoology · Cited by 317
Martin, H. J., Yule, V., Syddall, H. E., Dennison, E. M., Cooper, C., & Aihie Sayer, A. (2006) · Gerontology · doi:10.1159/000091824 · Cited by 309
Stratford, P. W. (2004) · Physiotherapy Canada · doi:10.2310/6640.2004.15377 · Cited by 302 · cited 3×
“range within which a truly unchanged participant score would be expected to remain over repeat testing, at a 95%CI [19].”
BackgroundMethodInfluentialKelln, B. M., McKeon, P. O., Gontkof, L. M., & Hertel, J. (2008) · Journal of Sport Rehabilitation · doi:10.1123/jsr.17.2.160 · Cited by 267 · cited 15×
“[9] reports SEM% of only 1% while Arnold et al.”
BackgroundMethodInfluentialArnold, C. M., Warkentin, K. D., Chilibeck, P. D., & Magnus, C. R. A. (2010) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181aa36b8 · Cited by 218 · cited 9×
“[9,11,26] One used a Hoggan Health HHD [9]; one used a Lafayette HHD [11]; and one used both the Hoggan Health and Lafayette HHDs [26] ; two studies assessed hip flexion while seated, [9,26] and the third assessed flexion while standing.”
BackgroundMethodInfluentialClinical Reliability of Manual Muscle Testing
Frese, E., Brown, M., & Norton, B. J. (1987) · Physical Therapy · doi:10.1093/ptj/67.7.1072 · Cited by 193
Reproducibility of an Isokinetic Strength-Testing Protocol of the Knee and Ankle in Older Adults
Hartmann, A., Knols, R., Murer, K., & de Bruin, E. D. (2009) · Gerontology · doi:10.1159/000172832 · Cited by 192
de Araujo Ribeiro Alvares, J. B., Rodrigues, R., de Azevedo Franke, R., da Silva, B. G. C., Pinto, R. S., Vaz, M. A., & Baroni, B. M. (2015) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2014.04.004 · Cited by 190 · cited 1×
“The strap system applied for body fixation and patient comfort during testing [47] may contribute noise to the measurements that can alter subject performance.”
BackgroundTest–retest reliability of EMG and peak torque during repetitive maximum concentric knee extensions
Larsson, B. K., Karlsson, S., Eriksson, M., & Gerdle, B. U. C. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(03)00022-1 · Cited by 159 · cited 3×
“Three [16,24,32] of the fifteen studies presented fair methodological quality, and twelve [9,11,17,25-31,33,34] presented poor quality.”
BackgroundBrandsma, J. W., Schreuders, T. A. R., Birke, J. A., Piefer, A., & Oostendorp, R. A. B. (1995) · Journal of Hand Therapy · doi:10.1016/s0894-1130(12)80014-7 · Cited by 153 · cited 1×
“Nevertheless, when standardized techniques are used, the inter- and intra-rater reliability of manual testing prominently improves in healthy populations [44,45].”
MethodBohannon, R. W. (1990) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/11/3/004 · Cited by 128 · cited 1×
“For example, the knee extensors are a very strong muscle group and require a strong practitioner for accurate testing [13,46].”
BackgroundKim, W. K., Kim, D., Seo, K. M., & Kang, S. H. (2014) · Annals of Rehabilitation Medicine · doi:10.5535/arm.2014.38.1.84 · Cited by 125
RELIABILITY OF ISOKINETIC ANKLE DORSIFLEXOR STRENGTH MEASUREMENTS IN HEALTHY YOUNG MEN AND WOMEN
Holmbäck, A. M. (1999) · Scandinavian Journal of Rehabilitation Medicine · doi:10.1080/003655099444407 · Cited by 106 · cited 3×
“Additionally, four studies were included for ankle dorsiflexion analysis [17,26,30,38].”
BackgroundMethodAssessment of Quadriceps Muscle Performance by a Hand-Held Dynamometer and an Isokinetic Dynamometer
Deones, V. L., Wiley, S., & Worrell, T. W. (1994) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1994.20.6.296 · Cited by 97 · cited 2×
“The reliability of the HHD test is known to increase when the rater is stronger than the subject [1].”
BackgroundInterdevice Reliability and Validity Assessment of the Nicholas Hand-Held Dynamometer
Trudelle-Jackson, E. J., Jackson, A. W., Frankowski, C. M., et al. (1994) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1994.20.6.302 · Cited by 87 · cited 1×
“Assessing muscle strength is an important clinical consideration for patients who may have a neurological, muscular, and/or skeletal illness [1,2].”
BackgroundGross, M. T., Huffman, G. M., Phillips, C. N., et al. (1991) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1991.13.6.329 · Cited by 82 · cited 1×
“While Thompson [50] suggested no difference between the Biodex and Cybex IDs for the knee flexors, Gross [51] demonstrated that knee flexion tests performed on the Cybex ID reached higher peak torque values.”
BackgroundCarvalho, A., Caserotti, P., Carvalho, C., Abade, E., & Sampaio, A. J. D. E. (2013) · Journal of Human Kinetics · doi:10.2478/hukin-2013-0024 · Cited by 82 · cited 4×
“Three [16,24,32] of the fifteen studies presented fair methodological quality, and twelve [9,11,17,25-31,33,34] presented poor quality.”
BackgroundMethodInfluentialReliability of shoulder rotators isokinetic strength imbalance measured using the Biodex dynamometer
Édouard, P., Codine, P., Samozino, P., Bernard, P. L., Hérisson, C., & Grémeaux, V. (2012) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2012.01.007 · Cited by 73 · cited 1×
“For example, Edouard et al [41] reported that the reliability of ID shoulder rotator strength assessments is dependent on shoulder position (i.”
BackgroundLu, T.-W., Hsu, H., Chang, L. Y., & Chen, H. (2007) · Acta Dermato Venereologica · doi:10.2340/16501977-0107 · Cited by 69
Test–retest reliability of cardinal plane isokinetic hip torque and EMG
Claiborne, T. L., Timmons, M. K., & Pincivero, D. M. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.07.005 · Cited by 59 · cited 6×
“One [26] assessed the movements in a supine position using the Kin Com ID, whereas the second study used a supine position with the Biodex ID [28].”
BackgroundMethodInfluentialGolriz, S., Hébert, J. J., Foreman, K. B., & Walker, B. F. (2012) · Chiropractic & Manual Therapies · doi:10.1186/2045-709x-20-15 · Cited by 32
Shoulder Abduction Strength Measurement in Football Players
Burnham, R. S., Bell, G. R., Olenik, L. M., & Reid, D. C. (1995) · Clinical Journal of Sport Medicine · doi:10.1097/00042752-199504000-00004 · Cited by 28
Ferri‐Morales, A., Alegre, L. M., Basco, A., & Jódar, X. A. (2014) · Isokinetics and Exercise Science · doi:10.3233/ies-130522 · Cited by 23 · cited 5×
“Randomization was not applicable in three studies [16,32,34].”
BackgroundInfluentialNeil‐Sztramko, S., Myring, A., Peeters, M. J., Pirie, I., Jacobs, R., Hunt, M. A., Garland, S. J., & Campbell, K. L. (2013) · Physiotherapy Theory and Practice · doi:10.3109/09593985.2013.779337 · Cited by 20
Kawaguchi, J. K., & Babcock, G. J. (2010) · Athletic Training & Sports Health Care · doi:10.3928/19425864-20101221-04 · Cited by 15
Lu, T., Chien, H.-L., Chang, L.-Y., & Hsu, H. (2011) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31823db080 · Cited by 12 · cited 8×
“Four studies used a seated position [11,24,26,27] and one used a prone position.”
BackgroundMethodInfluentialWang, Y.-C., Bohannon, R. W., Magasi, S. R., Hrynkiewicz, B., Morales, A., Gershon, R. C., & Rymer, Z. (2011) · Isokinetics and Exercise Science · doi:10.3233/ies-2011-0410 · Cited by 11
Holmbäck, A. M., & Lexell, J. E. (2007) · Isokinetics and Exercise Science · doi:10.3233/ies-2007-0282 · Cited by 10 · cited 6×
“Randomization was not applicable in three studies [16,32,34].”
BackgroundResultInfluential
Cited by
Pizol, G. Z., Ferro Moura Franco, K., Cristiane Miyamoto, G., & Maria Nunes Cabral, C. (2023) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-023-06920-x · Cited by 9
Metadata
- Authors
- Chamorro, C., Armijo-Olivo, S., De la Fuente, C., Fuentes, J., & Javier Chirosa, L.
- Venue
- Open Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2017-10-01
- Volume
- 12
- Issue
- 1
- Pages
- 359-375
- ISSN
- 1895-1058 (ISSN-L)
- 2391-5463
- OpenAlex
- W2765605718
- Cited by
- 195
- References
- 39
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.