Nebulizers for drug delivery to the lungs
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Nebulizers are the oldest modern method of delivering aerosols to the lungs for the purpose of respiratory drug delivery. While use of nebulizers remains widespread in the hospital and home setting, certain newer nebulization technologies have enabled more portable use. Varied fundamental processes of droplet formation and breakup are used in modern nebulizers, and these processes impact device performance and suitability for nebulization of various formulations. AREAS COVERED: This review first describes basic aspects of nebulization technologies, including jet nebulizers, various high-frequency vibration techniques, and the use of colliding liquid jets. Nebulizer use in hospital and home settings is discussed next. Complications in aerosol droplet size measurement owing to the changes in nebulized droplet diameters due to evaporation or condensation are discussed, as is nebulization during mechanical ventilation. EXPERT OPINION: While the limelight may often appear to be focused on other delivery devices, such as pressurized metered dose and dry powder inhalers, the ease of formulating many drugs in water and delivering them as aqueous aerosols ensures that nebulizers will remain as a viable and relevant method of respiratory drug delivery. This is particularly true given recent improvements in nebulizer droplet production technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma
Cates, C. J., Welsh, E. J., & Rowe, B. H. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000052.pub3 · Cited by 359
Tiotropium Respimat Inhaler and the Risk of Death in COPD
Wise, R. A., Anzueto, A., Cotton, D., Dahl, R., Devins, T., Disse, B., Dusser, D., Joseph, E., Kattenbeck, S., Koenen-Bergmann, M., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303342 · Cited by 333 · cited 1×
“A recently completed, large-scale randomized clinical trial found no difference in safety or efficacy between tiotropium delivered to COPD patients via Respimat versus the HandiHaler DPI (Boehringer Ingelheim) [102].”
BackgroundThe science of nebulised drug delivery
O'Callaghan, C., & Barry, P. W. (1997) · Thorax · doi:10.1136/thx.52.2008.s31 · Cited by 293 · cited 1×
“Reprinted from [105] with permission from BMJ Publishing Group Ltd.”
MethodCo-Chairmen of the Task Force:, Boe, J., Dennis, J. H., O'Driscoll, B. R., Members of Task Force:, Bauer, T. T., Carone, M., Dautzenberg, B., Diot, P., Heslop, K., et al. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.00220001 · Cited by 280
Aerosol Delivery and Modern Mechanical Ventilation
Miller, D. D., Amin, M. M., Palmer, L. B., Shah, A. R., & Smaldone, G. C. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1167oc · Cited by 224 · cited 1×
“When jet nebulizers are used with ventilator breathing circuits, there exists potential for the additional flow output from the nebulizer to interfere with operation of the ventilator [69], and for nebulizer drug to simply be swept from the inspiratory to expiratory circuit along with bias flow [67,70].”
MethodLu, Q., Yang, J., Liu, Z., Gutierrez, C., Aymard, G., Rouby, J.-J., & the Nebulized Antibiotics Study Group (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201011-1894oc · Cited by 214 · cited 1×
“Nebulized antibiotics have also been widely studied for treatment of pneumonia in ventilated patients [64-68].”
BackgroundLu, Q., Luo, R., Bodin, L., Yang, J., Zahr, N., Aubry, A., Golmard, J.-L., & Rouby, J.-J. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31827515de · Cited by 207
Miniature inhalation therapy platform using surface acoustic wave microfluidic atomization
Qi, A., Friend, J. R., Yeo, L. Y., Morton, D. A. V., McIntosh, M. P., & Spiccia, L. (2009) · Lab on a Chip · doi:10.1039/b903575c · Cited by 189 · cited 2×
“A higher frequency, lower power, more recent ultrasonic approach instead uses surface acoustic waves (SAWs) induced on a piezoelectric crystal to produce aerosol droplets (Figure 1) [22,23].”
BackgroundMethodHeliox for non-intubated acute asthma patients
Rodrigo, G. J., Pollack, C. V., Rodrigo, C., & Rowe, B. H. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002884.pub2 · Cited by 174
Liposomal Formulations for Inhalation
Cipolla, D. C., Gonda, I., & Chan, H. (2013) · Therapeutic Delivery · doi:10.4155/tde.13.71 · Cited by 166 · cited 1×
“The repeated stresses associated with repeated exposure to droplet formation, breakup and impaction can make jet nebulization unsuitable for certain easily degraded large molecules and liposomes [14].”
BackgroundMcCallion, O. N. M., Taylor, K. M. G., Thomas, M., & Taylor, A. J. (1995) · Pharmaceutical Research · doi:10.1023/a:1016205520044 · Cited by 150 · cited 1×
“However, difficulties with nebulizing high-viscosity liquids [19], suspensions [16], as well as significant heating of the nebulizer solution [20], which can be problematic for heat-sensitive drugs like rhDNase [21], limits their generality.”
BackgroundDeposition in Asthmatics of Particles Inhaled in Air or in Helium-Oxygen
Anderson, M. P., Svartengren, M., Bylin, G., Philipson, K., & Camner, P. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.3.524 · Cited by 147 · cited 1×
“In contrast, helium/oxygen mixtures (heliox) are in some cases used to reduce patient airway resistance, primarily during severe acute asthma [53], and hypothetically deliver a greater amount of aerosol to obstructed airways [54-58].”
BackgroundClark, A. R. (1995) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(94)00255-4 · Cited by 145 · cited 1×
“An alternative approach is to use optical sizing methods such as phase Doppler anemometry [35,36] or laser diffraction [37,38], which if used properly can avoid such particle sizing errors.”
MethodProtein stability in pulmonary drug delivery via nebulization
Hertel, S., Winter, G., & Frieß, W. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.10.003 · Cited by 123 · cited 1×
“While this shearing is necessary for droplet production, exposure of large molecules, such as proteins or DNA, to such shear may be partly responsible for drug degradation seen by some authors [9,10].”
BackgroundHodder, R., & Price, D. B. (2009) · International Journal of COPD · doi:10.2147/copd.s3391 · Cited by 121
Aerosol Deposition in Neonatal Ventilation
Dubus, J. ‐., Vecellio, L., Monte, M. D., Fink, J. B., Grimbert, D., Montharu, J., Valat, C., Behan, N., & Diot, P. (2005) · Pediatric Research · doi:10.1203/01.pdr.0000156244.84422.55 · Cited by 111 · cited 1×
“Similarly, improvements in efficiency of delivery for vibrating mesh compared with jet nebulizers have been noted for ventilation of children and infants [83,84].”
BackgroundAerosolized Antibiotics for Ventilator-associated Pneumonia: Lessons from Experimental Studies
Rouby, J., Bouhemad, B., Monsel, A., Brisson, H., Arbelot, C., & Lü, Q. (2012) · Anesthesiology · doi:10.1097/aln.0b013e3182755d7a · Cited by 101
Adams, W. P., Ahrens, R. C., Chen, M.-L., Christopher, D., Chowdhury, B. A., Conner, D. P., Dalby, R. N., Fitzgerald, K., Hendeles, L., Hickey, A. J., et al. (2010) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2009.0803 · Cited by 95
Rajapaksa, A. E., Ho, J. J., Qi, A., Bischof, R. J., Nguyen, T., Tate, M. D., Piedrafita, D. M., McIntosh, M. P., Yeo, L. Y., Meeusen, E. N. T., et al. (2014) · Respiratory Research · doi:10.1186/1465-9921-15-60 · Cited by 92 · cited 2×
“A higher frequency, lower power, more recent ultrasonic approach instead uses surface acoustic waves (SAWs) induced on a piezoelectric crystal to produce aerosol droplets (Figure 1) [22,23].”
BackgroundThe Adaptive Aerosol Delivery (AAD) Technology: Past, Present, and Future
Denyer, J., & Dyche, T. (2010) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2009.0791 · Cited by 82 · cited 2×
“One marketed device incorporating vibrating mesh technology, Philips’ i-neb [96,99], is intended for use as a portable device that can be carried outside the home.”
BackgroundMethodTuinman, P. R., Dixon, B., Levi, M. M., Juffermans, N. P., & Schultz, M. J. (2012) · Critical Care · doi:10.1186/cc11325 · Cited by 78 · cited 1×
“Several recent reviews examine the role of nebulizers in treating specific illnesses, conditions or symptoms of illness, for example, cystic fibrosis [1], acute lung injury [2], ventilatorassociated pneumonia [3], dyspnea [4] and acute asthma [5].”
BackgroundNovel approaches to enhance pulmonary delivery of proteins and peptides.
Scheuch, G., & Siekmeier, R. (2007) · PubMed · Cited by 76
Adaptive Aerosol Delivery (AAD®) technology
Denyer, J., Nikander, K., & Smith, N. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.165 · Cited by 75 · cited 2×
“One marketed device incorporating vibrating mesh technology, Philips’ i-neb [96,99], is intended for use as a portable device that can be carried outside the home.”
BackgroundMethodPulmonary deposition of a nebulised aerosol during mechanical ventilation.
Thomas, S. H. L., O'Doherty, M. J., Fidler, H., Page, C. J., Treacher, D., & NUNAN, T. O. (1993) · Thorax · doi:10.1136/thx.48.2.154 · Cited by 74
Montgomery, A. B., Vallance, S., Abuan, T., Tservistas, M., & Davies, A. (2014) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2013.1100 · Cited by 74 · cited 3×
“The droplet size distribution produced by the nebulizer is also an important determinant of aerosol losses in the breathing circuit [64,81].”
BackgroundMethodFischer, A., Stegemann, J., Scheuch, G., & Siekmeier, R. (2009) · European journal of medical research · doi:10.1186/2047-783x-14-s4-71 · Cited by 69 · cited 1×
“Such systems include Activaero’s Akita and Philips’ i-neb [95-99].”
MethodFilho, V. G., Brandão, D. C., Ferreira, R. D. C. D. S., Menezes, M. J. C., Almeida-Filho, P., Parreira, V. F., Silva, T. N., Rodrigues‐Machado, M. D. G., Dean, E., & de Andrade, A. D. (2012) · Respiratory Care · doi:10.4187/respcare.01371 · Cited by 68 · cited 1×
“Delivery of nebulized drugs during ventilation using noninvasive patient interfaces has received considerable recent attention [85,86].”
BackgroundLentz, Y. K., Worden, L. R., Anchordoquy, T. J., & Lengsfeld, C. (2005) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.11.017 · Cited by 65 · cited 1×
“While this shearing is necessary for droplet production, exposure of large molecules, such as proteins or DNA, to such shear may be partly responsible for drug degradation seen by some authors [9,10].”
BackgroundMelani, A. S., Canessa, P., Coloretti, I., DeAngelis, G., DeTullio, R., Donno, M. D., Giacobbe, R., Scarlato, I., Serafini, A., Barbato, N., et al. (2012) · Respiratory Medicine · doi:10.1016/j.rmed.2011.11.016 · Cited by 59 · cited 1×
“Use of nebulizers in patient’s homes or other domiciliary settings is common, though selection of nebulizers in place of pMDIs or DPIs in many cases follows local prescribing habits, rather than published guidelines or evidence [43,91].”
BackgroundNebulized Medications for the Treatment of Dyspnea: A Literature Review
Boyden, J. Y., Connor, S. R., Otolorin, L., Nathan, S. D., Fine, P. G., Davis, M. S., & Muir, J. C. (2014) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2014.1136 · Cited by 56 · cited 1×
“Several recent reviews examine the role of nebulizers in treating specific illnesses, conditions or symptoms of illness, for example, cystic fibrosis [1], acute lung injury [2], ventilatorassociated pneumonia [3], dyspnea [4] and acute asthma [5].”
BackgroundMellon, M. H., Leflein, J. G., Walton-Bowen, K. L., Cruz‐Rivera, M., Fitzpatrick, S. B., & Smith, J. A. J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9909030 · Cited by 53 · cited 1×
“A mouthpiece should in theory deliver more medication to the lungs due to the lower particle filtration efficiency of the mouth compared to the nose in adults (but not in infants [39]), and due to avoidance of aerosol deposition on the face; however, clinical studies have not consistently found improved efficacy with…”
BackgroundAbu-Salah, T., & Dhand, R. (2011) · Advances in Therapy · doi:10.1007/s12325-011-0051-z · Cited by 49
Kim, J., Xi, J., Si, X. A., Berlinski, A., & Su, W. C. (2013) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2013.1051 · Cited by 48 · cited 1×
“facemasks and mouthpieces, primarily for the purpose of alleviating patient discomfort [46-49].”
Nebuliser systems for drug delivery in cystic fibrosis
Daniels, T. E., Mills, N., & Whitaker, P. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007639.pub2 · Cited by 46 · cited 1×
“Several recent reviews examine the role of nebulizers in treating specific illnesses, conditions or symptoms of illness, for example, cystic fibrosis [1], acute lung injury [2], ventilatorassociated pneumonia [3], dyspnea [4] and acute asthma [5].”
BackgroundAerosol Delivery in Respiratory Syncytial Virus Bronchiolitis: Hood or Face Mask?
Amirav, I., Oron, A., Tal, G., Cesar, K., Ballin, A., Houri, S., Naugolni, L., & Mandelberg, A. (2005) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2005.05.035 · Cited by 38 · cited 1×
“facemasks and mouthpieces, primarily for the purpose of alleviating patient discomfort [46-49].”
BackgroundAn In Vitro Method for Determining Regional Dosages Delivered by Jet Nebulizers
STAPLETON, K. W., Finlay, W. H., & ZUBERBUHLER, P. (1994) · Journal of Aerosol Medicine · doi:10.1089/jam.1994.7.325 · Cited by 36
Self-citationFinlay, W. H. (2001) · Elsevier eBooks · doi:10.1016/b978-012256971-5/50010-9 · Cited by 32
Self-citationDenyer, J., BLACK, A. M. S., Nikander, K., Dyche, T., & Prince, I. (2010) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2009.0777 · Cited by 20 · cited 1×
“Such systems include Activaero’s Akita and Philips’ i-neb [95-99].”
MethodStabilizing protein formulations during air-jet nebulization
Albasarah, Y. Y., Somavarapu, S., & Taylor, K. M. G. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.09.042 · Cited by 20 · cited 1×
“[11], among others, have seen a reduction in such drug degradation with the addition of protective agents.”
BackgroundLelong, N., Junqua‐Moullet, A., Diot, P., & Vecellio, L. (2013) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2012.1030 · Cited by 20 · cited 1×
“An alternative approach is to use optical sizing methods such as phase Doppler anemometry [35,36] or laser diffraction [37,38], which if used properly can avoid such particle sizing errors.”
MethodGurses, B. K., & Smaldone, G. C. (2003) · Journal of Aerosol Medicine · doi:10.1089/089426803772455640 · Cited by 14
Cited by
Nanoemulsions in Drug Delivery: Formulation to Medical Application
Tayeb, H. H., & Sainsbury, F. (2018) · Nanomedicine · doi:10.2217/nnm-2018-0088 · Cited by 190
Leveraging Physiology for Precision Drug Delivery
Sun, W., Hu, Q., Ji, W., Wright, G., & Gu, Z. (2017) · Physiological Reviews · doi:10.1152/physrev.00015.2016 · Cited by 169
Metadata
- Authors
- Martin, A. R., & Finlay, W. H.
- Venue
- Expert Opinion on Drug Delivery
- Publisher
- Informa Healthcare
- Published
- 2014-12-23
- Volume
- 12
- Issue
- 6
- Pages
- 889-900
- ISSN
- 1742-5247 (ISSN-L)
- 1744-7593
- OpenAlex
- W2008088907
- Cited by
- 197
- References
- 41
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.