Haptic Force-Feedback Devices for the Office Computer: Performance and Musculoskeletal Loading Issues
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Pointing devices, essential input tools for the graphical user interface (GUI) of desktop computers, require precise motor control and dexterity to use. Haptic force-feedback devices provide the human operator with tactile cues, adding the sense of touch to existing visual and auditory interfaces. However, the performance enhancements, comfort, and possible musculoskeletal loading of using a force-feedback device in an office environment are unknown. Hypothesizing that the time to perform a task and the self-reported pain and discomfort of the task improve with the addition of force feedback, 26 people ranging in age from 22 to 44 years performed a point-and-click task 540 times with and without an attractive force field surrounding the desired target. The point-and-click movements were approximately 25% faster with the addition of force feedback (paired t-tests, p < 0.001). Perceived user discomfort and pain, as measured through a questionnaire, were also smaller with the addition of force feedback (p < 0.001). However, this difference decreased as additional distracting force fields were added to the task environment, simulating a more realistic work situation. These results suggest that for a given task, use of a force-feedback device improves performance, and potentially reduces musculoskeletal loading during mouse use. Actual or potential applications of this research include human-computer interface design, specifically that of the pointing device extensively used for the graphical user interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1954) · Journal of Experimental Psychology · doi:10.1037/h0055392 · Cited by 6,466
Cited by
Effect of sensory substitution on suture-manipulation forces for robotic surgical systems
Kitagawa, M., Dokko, D., Okamura, A. M., & Yuh, D. D. (2005) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.05.029 · Cited by 278
Probabilistic pointing target prediction via inverse optimal control
Ziebart, B., Dey, A., & Bagnell, J. A. (2012) · Proceedings of the 2012 ACM international conference on Intelligent User Interfaces · doi:10.1145/2166966.2166968 · Cited by 90
Surfpad: riding towards targets on a squeeze film effect
Casiez, G., Roussel, N., Vanbelleghem, R., & Giraud, F. (2011) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1978942.1979307 · Cited by 73
“The second experiment described in [16] displayed 13 targets arranged in a cross shape and required the user to randomly move from one to another, all the others acting as potentially avoidable distractors.”
BackgroundInfluentialWobbrock, J. O. (2014) · Advances in Medical Technologies and Clinical Practice · doi:10.4018/978-1-4666-4438-0.ch008 · Cited by 12
Metadata
- Authors
- Dennerlein, J. T., & Yang, M. C.
- Venue
- Human Factors: The Journal of the Human Factors and Ergonomics Society
- Publisher
- SAGE Publications
- Published
- 2001-06
- Volume
- 43
- Issue
- 2
- Pages
- 278-286
- ISSN
- 0018-7208 (ISSN-L)
- 1547-8181
- OpenAlex
- W2077399576
- Cited by
- 97
- References
- 1
- FWCI
- 14.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Haptic Force-Feedback Devices for the Office Computer: Performance and Musculoskeletal Loading Issues. https://app.cochat.ai/papers/10.1518/001872001775900850
- The paper
- Dennerlein, J. T., & Yang, M. C. (2001). Haptic Force-Feedback Devices for the Office Computer: Performance and Musculoskeletal Loading Issues. Human Factors: The Journal of the Human Factors and Ergonomics Society. https://doi.org/10.1518/001872001775900850
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.