SPECIAL SECTION: Users as Designers: How People Cope with Poor HCI Design in Computer-Based Medical Devices
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper we examine how users interact with a computer-based infusion device adapted for terbutaline infusion to treat preterm labor in women experiencing high-risk pregnancies. This study examines (a) the human-computer interaction (HCI) deficiencies in the device as related to this context of use, (b) how the device characteristics increase the potential for error, and (c) the tailoring strategies developed by users to insulate themselves from failure. Interviews with nurses and tests of the behavior of the infusion device in different conditions identified several classic HCI deficiencies: complex and arbitrary sequences of operation, mode errors caused by poor differentiation of multiple operating modes intended for different contexts, ambiguous alarms, getting lost in multiple displays, and poor feedback on device state and behavior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reason, J. (1990) · doi:10.1017/cbo9781139062367 · Cited by 5,108
Cited by
Sax, H., Allegranzi, B., Uçkay, I., Larson, E., Boyce, J., & Pittet, D. (2007) · Journal of Hospital Infection · doi:10.1016/j.jhin.2007.06.004 · Cited by 808
Using usability heuristics to evaluate patient safety of medical devices
Zhang, J., Johnson, T. R., Patel, V. L., Paige, D. L., & Kubose, T. (2003) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00060-1 · Cited by 591
Benefits of and barriers to involving users in medical device technology development and evaluation
Shah, S. G. S., & Robinson, I. (2007) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462307051677 · Cited by 299
Kushniruk, A. W., Triola, M. M., Borycki, E. M., Stein, B., & Kannry, J. L. (2005) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2005.01.003 · Cited by 277
Anticipating the effects of technological change: A new era of dynamics for human factors
Woods, D., & Dekker, S. (2000) · Theoretical Issues in Ergonomics Science · doi:10.1080/14639220110037452 · Cited by 268
Self-citation
Metadata
- Authors
- Obradovich, J. H., & Woods, D. D.
- Venue
- Human Factors: The Journal of the Human Factors and Ergonomics Society
- Publisher
- SAGE Publications
- Published
- 1996-12
- Volume
- 38
- Issue
- 4
- Pages
- 574-592
- ISSN
- 0018-7208 (ISSN-L)
- 1547-8181
- OpenAlex
- W2106444124
- Cited by
- 124
- References
- 1
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SPECIAL SECTION: Users as Designers: How People Cope with Poor HCI Design in Computer-Based Medical Devices. https://app.cochat.ai/papers/10.1518/001872096778827251
- The paper
- Obradovich, J. H., & Woods, D. D. (1996). SPECIAL SECTION: Users as Designers: How People Cope with Poor HCI Design in Computer-Based Medical Devices. Human Factors: The Journal of the Human Factors and Ergonomics Society. https://doi.org/10.1518/001872096778827251
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.