CoChat

Using Near-Infrared Spectroscopy to Determine Maximal Steady State Exercise Intensity

Snyder, Ann C, Parmenter, Mark A · 2009 · Journal of Strength and Conditioning Research

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

Maximal steady state (MSS) speed can be determined from blood lactate concentration (HLa); however, this method is not optimal. The purpose of this study was to determine whether near-infrared spectroscopy (NIRS) technology could be used to detect a breakpoint in percent oxygen saturation (StO2) of the muscle and whether the determined breakpoint exercise intensity could be used to determine MSS exercise intensity. Sixteen distance runners and triathletes (men = 9, VO2max = 64.9 +/- 4.9 ml x kg(-1) x min(-1), women = 7, VO2max = 50.8 +/- 7.0 ml x kg(-1) x min(-1)) completed an incremental exercise test. A change from linearity when plotting StO2 or HLa vs. running speed was defined as the breakpoint. The subjects then completed constant speed runs to determine maximal lactate steady state (MLSS). In 12 subjects, breakpoints were identified for both HLa and StO2 values. Predicted MLSS velocities from HLa breakpoint (12.76 +/- 1.63 km x h(-1)), StO2 breakpoint (12.84 +/- 1.58 km x h(-1)), and 4 mM HLa (13.49 +/- 1.71 km x h(-1)) methods from the incremental test did not differ from MLSS speeds (13.04 +/- 2.03 km x h(-1)). A Bland and Altman analysis of agreement between the MLSS and the StO2 breakpoint speeds resulted in a mean difference of 0.14 +/- 0.36, whereas the mean difference between MLSS and HLa breakpoint speeds was 0.19 +/- 0.43. During the incremental test, no StO2 breakpoint was determined in 2 subjects, whereas 2 subjects had no HLa breakpoint. The results of this…

Overview

Integrity signals

Registry

Crossref · 10.1519/jsc.0b013e3181ad3362

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 30 references

Research works printed but not linked: 2

  1. 2004, Kuipers, H, Rietjens, G, Verstappen, F, Schoenmakers, H, and Hoffman, G. Effects of stage duration in incremental running tests on physiological variables., Int J Sports Med, 24, 1
  2. 2005, Vobejda, C, Fromme, K, Samson, W, and Zimmerman, E. Maximal constant heart rate: a heart rate based method to estimate maximal lactate steady state in running., Int J Sports Med, 7, 368

Cited by

See all 36

Metadata

Authors
Snyder, A. C., & Parmenter, M. A.
Affiliations
University of Wisconsin–Milwaukee (US)
Corresponding author
Snyder, Ann C
Venue
Journal of Strength and Conditioning Research
Published
2009-09
Volume
23
Issue
6
Pages
1833-1840
ISSN
1064-8011 (ISSN-L)
OpenAlex
W2090194081
Cited by
32
References
30
Citations by year
2026: 5 · 2025: 6 · 2024: 3 · 2023: 4 · 2022: 3 · 2021: 3 · 2019: 2 · 2018: 1 · 2016: 3
FWCI
1.61
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Strength and Conditioning Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
maximal lactate steady state, near-infrared spectroscopy, muscle oxygen saturation, blood lactate, change point detection, incremental exercise test, running speed, exercise training intensity, long-distance runners, triathletes
MeSH terms
Adult, Exercise Test, Female, Humans, Lactates, Male, Oxygen Consumption, Physical Endurance, Running, Muscle, Skeletal, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.