Validity and Reliability of the Myotest Accelerometric System for the Assessment of Vertical Jump Height
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The aim of the present study was to verify the validity and reliability of the Myotest accelerometric system (Myotest SA, Sion, Switzerland) for the assessment of vertical jump height. Forty-four male basketball players (age range: 9-25 years) performed series of squat, countermovement and repeated jumps during 2 identical test sessions separated by 2-15 days. Flight height was simultaneously quantified with the Myotest system and validated photoelectric cells (Optojump). Two calculation methods were used to estimate the jump height from Myotest recordings: flight time (Myotest-T) and vertical takeoff velocity (Myotest-V). Concurrent validity was investigated comparing Myotest-T and Myotest-V to the criterion method (Optojump), and test-retest reliability was also examined. As regards validity, Myotest-T overestimated jumping height compared to Optojump (p < 0.001) with a systematic bias of approximately 7 cm, even though random errors were low (2.7 cm) and intraclass correlation coefficients (ICCs) where high (>0.98), that is, excellent validity. Myotest-V overestimated jumping height compared to Optojump (p < 0.001), with high random errors (>12 cm), high limits of agreement ratios (>36%), and low ICCs (<0.75), that is, poor validity. As regards reliability, Myotest-T showed high ICCs (range: 0.92-0.96), whereas Myotest-V showed low ICCs (range: 0.56-0.89), and high random errors (>9 cm). In conclusion, Myotest-T is a valid and reliable method for the assessment of vertical jump height, and its use is legitimate for field-based evaluations, whereas Myotest-V is neither valid nor reliable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Reliability of techniques to assess human neuromuscular function in vivo
Clark, B. C., Cook, S. B., & Ploutz-Snyder, L. L. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2005.11.008 · Cited by 107 · cited 1×
“1) to the magnitude of the mean (1), limits of agreement (LOA) ratios were also calculated (7).”
Cited by
The validity and reliability of an iPhone app for measuring vertical jump performance
Balsalobre-Fernández, C., Glaister, M., & Lockey, R. A. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2014.996184 · Cited by 621
Camomilla, V., Bergamini, E., Fantozzi, S., & Vannozzi, G. (2018) · Sensors · doi:10.3390/s18030873 · Cited by 591
A Brief Review of Strength and Ballistic Assessment Methodologies in Sport
McMaster, D. T., Gill, N., Cronin, J., & McGuigan, M. (2014) · Sports Medicine · doi:10.1007/s40279-014-0145-2 · Cited by 264
Amin Mohammadian, M., Mozayyany, H., Bagheri Koudakani, S., & Maloney, S. J. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112338 · Cited by 5
Metadata
- Authors
- Casartelli, N., Müller, R., & Maffiuletti, N. A.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2010-11
- Volume
- 24
- Issue
- 11
- Pages
- 3186-3193
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W2078480793
- Cited by
- 183
- References
- 2
- FWCI
- 8.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.