The DOI matches its Crossref record.
The Validity and Reliability of 5-hZ Global Positioning System Units to Measure Team Sport Movement Demands
Abstract
The purpose of this research was to investigate the validity and the reliability of 5-Hz MinimaxX global positioning system (GPS) units measuring athlete movement demands. A team sport simulation circuit (files collected from each unit = 12) and flying 50-m sprints (files collected from each unit = 34) were undertaken, during which the total distance covered; peak speed; player load; the distance covered; time spent and number of efforts performed walking, jogging, running, high-speed running, and sprinting were examined. Movement demands were also separately categorized into low-intensity activity, high-intensity running, and very high-intensity running. The results revealed that GPS was a valid and reliable measure of total distance covered (p > 0.05, percentage typical error of measurement [%TEM] < 5%) and peak speed (p > 0.05, %TEM 5-10%). Further, GPS was found to be a reliable measure of player load (%TEM 4.9%) and the distance covered, time spent, and number of efforts performed at certain velocity zones (%TEM <5% to >10%). The level of GPS error was found to increase along with the velocity of exercise. The findings demonstrated that GPS is capable of measuring movement demands performed at velocities <20 km·h(-1), whereas more caution is to be exercised when analyzing movement demands collected by using GPS velocities >20 km·h(-1).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Global Positioning Systems (GPS) and Microtechnology Sensors in Team Sports: A Systematic Review
Cummins, C., Orr, R., O’Connor, H., & West, C. (2013) · Sports Medicine · doi:10.1007/s40279-013-0069-2 · Cited by 767
The Validity and Reliability of Global Positioning Systems in Team Sport: A Brief Review
Scott, M. T. U., Scott, T. J., & Kelly, V. G. (2016) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001221 · Cited by 509
Johnston, R. J., Watsford, M. L., Kelly, S. J., Pine, M. J., & Spurrs, R. W. (2014) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000323 · Cited by 447
Self-citationSprint Running Performance Monitoring: Methodological and Practical Considerations
Haugen, T., & Buchheit, M. (2016) · Sports Medicine · doi:10.1007/s40279-015-0446-0 · Cited by 385
Wearable Performance Devices in Sports Medicine
Li, R. T., Kling, S. R., Salata, M. J., Cupp, S. A., Sheehan, J., & Voos, J. E. (2016) · Sports Health: A Multidisciplinary Approach · doi:10.1177/1941738115616917 · Cited by 348
Metadata
- Authors
- Johnston, R. J., Watsford, M. L., Pine, M. J., Spurrs, R. W., Murphy, A. J., & Pruyn, E. C.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2012-03
- Volume
- 26
- Issue
- 3
- Pages
- 758-765
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W2087642481
- Cited by
- 158
- References
- 0
- FWCI
- 15.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Validity and Reliability of 5-hZ Global Positioning System Units to Measure Team Sport Movement Demands. https://app.cochat.ai/papers/10.1519/jsc.0b013e318225f161
- The paper
- Johnston, R. J., Watsford, M. L., Pine, M. J., Spurrs, R. W., Murphy, A. J., & Pruyn, E. C. (2012). The Validity and Reliability of 5-hZ Global Positioning System Units to Measure Team Sport Movement Demands. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0b013e318225f161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.