Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 192

The DOI matches its Crossref record.

Automatic gain control in the bat's sonar receiver and the neuroethology of echolocation

Open access
Kick, SA, Simmons, JA·1984·The Journal of Neuroscience

Abstract

The sensitivity of the echolocating bat, Eptesicus fuscus, to sonar echoes at different time delays after sonar emissions was measured in a two-choice echo detection experiment. Since echo delay is perceptually equivalent to target range, the experiment effectively measured sensitivity to targets at different ranges. The bat's threshold for detecting sonar echoes at a short delay of only 1.0 msec after emissions (corresponding to a range of 17 cm) was 36 dB SPL (peak to peak), but the threshold decreased to 8 dB SPL at a longer delay of 6.4 msec (a range of 1.1 m). Prior research has shown that, at even longer delays (corresponding to ranges of 3 to 5 m), the bat's threshold is in the region of 0 dB SPL. Contractions of the bat's middle ear muscles synchronized with the production of echolocation sounds cause a transient loss in hearing sensitivity which appears to account for the observed echo detection threshold shifts. The bat's echo detection thresholds increase by approximately 11 dB for each reduction in target range by a factor of 2 over the span from 17 cm to 1.1 m. As range shortens, the amplitude of echoes from small targets also increases, by 12 dB for each 2-fold reduction in range. Thus, when approaching a target, the bat compensates for changes in echo strength as target range shortens by changing its hearing threshold. Since this compensation appears to occur in the middle ear, the bat regulates echoes reaching the cochlea to a stable amplitude during its approach to a target such as a flying insect. In addition to this automatic gain control linked to target range, the bat aims its head to track a target's position during approach, thus stabilizing echo amplitude even if the target's direction changes. We hypothesize that the bat's directional emissions, directional hearing, middle ear muscle contractions, and head aim response collectively create a three- dimensional spatial tracking filter which the bat locks onto targets to stabilize echo amplitudes during interception of prey. We further hypothesize that this regulation, which cancels echo amplitude changes caused by the target's changing spatial position, leaves the bat free to observe echo amplitude changes caused by the target's own actions, such as insect wing beats. Elimination of spatially dependent echo amplitude changes removes the cause of potentially troublesome changes in neural response latency and keeps stimulation from echoes in the “tip” region of auditory nerve fiber tuning curves.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1523/jneurosci.04-11-02725.1984

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 192

Metadata

Authors
Kick, S., & Simmons, J.
Venue
The Journal of Neuroscience
Published
1984-11-01
Volume
4
Issue
11
Pages
2725-2737
ISSN
  • 0270-6474 (ISSN-L)
  • 1529-2401
OpenAlex
W1534994188
Cited by
192
References
0
FWCI
4.01
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic gain control in the bat's sonar receiver and the neuroethology of echolocation. https://app.cochat.ai/papers/10.1523/jneurosci.04-11-02725.1984
The paper
Kick, S., & Simmons, J. (1984). Automatic gain control in the bat's sonar receiver and the neuroethology of echolocation. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.04-11-02725.1984

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.