The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Chromatic and achromatic vision of macaques: role of the P pathway
Open accessAbstract
Chromatic and achromatic contrast sensitivity were measured in a human observer, 2 normal macaque monkeys, and 3 monkeys with severe toxicant- induced damage to the parvocellular projecting retinogeniculate pathway (P cell-deficient monkeys). Damage to the P pathway was produced by the oral administration of acrylamide monomer (Eskin and Merigan, 1986). Contrast sensitivity was measured in all subjects with isochromatic luminance gratings, as well as isoluminant chromatic gratings, modulated along several directions of a color space that represents color-opponent and luminance contrast (Krauskopf et al., 1986). The chromatic and achromatic sensitivity of the control monkeys was virtually identical to that of the human observer. Chromatic sensitivity of the P cell-deficient monkeys, measured at a low spatial frequency (0.3 c/deg), along a constant-blue color axis, was 0.9–1.5 log units lower than that of controls. Similar losses were seen along a tritanopic confusion axis and along 2 intermediate axes of color direction. Chromatic thresholds measured at higher spatial frequency (2.0 c/deg) were similarly reduced. Counterphase-modulated chromatic gratings were used to test color sensitivity over a range of temporal frequencies up to 15 Hz, and the loss of color vision was substantial over the entire range of frequencies. The luminance contrast sensitivity of the P cell-deficient monkeys for stationary gratings decreased after exposure by 0.5–0.8 log units. These results indicate that the chromatic and achromatic spatial vision of macaques is very similar to that of humans. They also suggest that the P pathway plays an important role in macaque chromatic sensitivity at all spatial frequencies, as well as achromatic sensitivity at high spatial and lower temporal frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Axial Chromatic Aberration of the Human Eye
Bedford, R. E., & Wyszecki, G. (1957) · Journal of the Optical Society of America · doi:10.1364/josa.47.0564_1 · Cited by 307
Cited by
How parallel are the primate visual pathways?
Merigan, W. H., & Maunsell, J. H. R. (1993) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.16.030193.002101 · Cited by 1,597
Self-citationParallel processing strategies of the primate visual system
Nassi, J. J., & Callaway, E. M. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2619 · Cited by 802
Previc, F. H. (1990) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00080018 · Cited by 675
Luminance and chromatic modulation sensitivity of macaque ganglion cells and human observers
Lee, B. B., Pokorny, J., Martin, P. R., Valbergt, A., & Smith, V. C. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.002223 · Cited by 504
The mosaic of midget ganglion cells in the human retina
Dacey, D. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-12-05334.1993 · Cited by 480
Metadata
- Authors
- Merigan, W.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 1989-03-01
- Volume
- 9
- Issue
- 3
- Pages
- 776-783
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W1659683147
- Cited by
- 171
- References
- 1
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chromatic and achromatic vision of macaques: role of the P pathway. https://app.cochat.ai/papers/10.1523/jneurosci.09-03-00776.1989
- The paper
- Merigan, W. (1989). Chromatic and achromatic vision of macaques: role of the P pathway. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.09-03-00776.1989
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.