The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Responses of human mechanoreceptive afferents to embossed dot arrays scanned across fingerpad skin
Open accessAbstract
The spatial resolving capacities of the four classes of mechanoreceptive afferents innervating human fingerpad skin were investigated to determine which class sets the limit of tactile spatial resolution for scanning stimuli. The stimulus consisted of an array of embossed dots (0.7 mm diameter, 0.5 mm high) arranged in a tetragonal pattern with dot spacing decreasing linearly from 6.4 mm at one end of the array to 0.87 mm at the other. The pattern was wrapped around a drum and repeatedly scanned across the receptive field of single afferents by continuously rotating the drum. Responses to many closely spaced scans were obtained by imposing a lateral shift of the pattern between each revolution. Impulses were recorded microneurographically. Responses were plotted in raster form to produce a neural image of the pattern. Responses of rapidly and slowly adapting type I (FAI and SAI) afferents resolved dots down to a spacing of about 1.5 mm. Responses of type II (FAII and SAII) afferents resolved dots down to a spacing of about 3.5 mm. Variation in scanning speed (range, 20–90 mm/sec) and contact force (range, 0.4–1.0 N) had minimal effects on spatial resolution of all afferents. The response clusters associated with individual widely spaced dots were used to investigate receptive field structure. FAI and SAI fields (mean areas, 6.1 and 4.8 mm2, respectively) each contained several zones of maximal sensitivity. FAI fields had five to eight such zones, whereas SAI fields had three to five such zones. As dot spacing decreased, neighboring dots interacted to affect the responses associated with the individual zones within a field. Initially, one or more zones were deactivated, effectively reducing receptive field size and allowing representation of finer spatial detail than would be predicted from the overall area of the receptive field. At very close dot spacings responses were only obtained when more than one sensitive zone within a field were simultaneously activated by different dots.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291
Self-citationOchoa, J., & Torebjörk, E. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014873 · Cited by 467 · cited 1×
“SA I a b C FA I --e h sensation (Ochoa and Torebjork, 1983).”
Johansson, R. S. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012411 · Cited by 430 · cited 4×
“Similar receptive field topography has been reported for human FAI and SAI afferents using punctate mapping techniques (Johansson, 1978) and for monkey afferents using scanned dots (Johnson and Iamb, 198 1) and stationary gratings (Phillips and Johnson, 198 la,b).”
BackgroundInfluentialSelf-citationTactile roughness: neural codes that account for psychophysical magnitude estimates
Connor, C., Hsiao, S., Phillips, Jr., & Johnson, K. (1990) · The Journal of Neuroscience · doi:10.1523/jneurosci.10-12-03823.1990 · Cited by 317
Self-citation
Cited by
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Self-citationReliability of spike timing in neocortical neurons
Mainen, Z. F., & Sejnowski, T. J. (1995) · Science · doi:10.1126/science.7770778 · Cited by 1,950
The roles and functions of cutaneous mechanoreceptors
Johnson, K. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00234-8 · Cited by 1,141
Self-citationFirst spikes in ensembles of human tactile afferents code complex spatial fingertip events
Johansson, R. S., & Birznieks, I. (2004) · Nature Neuroscience · doi:10.1038/nn1177 · Cited by 638
Self-citationEvidence for the duplex theory of tactile texture perception
Hollins, M., & Risner, S. R. (2000) · Perception & Psychophysics · doi:10.3758/bf03206916 · Cited by 440
Metadata
- Authors
- Phillips, Jr., Johansson, R., & Johnson, K.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 1992-03-01
- Volume
- 12
- Issue
- 3
- Pages
- 827-839
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W2124992632
- Cited by
- 158
- References
- 4
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Responses of human mechanoreceptive afferents to embossed dot arrays scanned across fingerpad skin. https://app.cochat.ai/papers/10.1523/jneurosci.12-03-00827.1992
- The paper
- Phillips, Jr., Johansson, R., & Johnson, K. (1992). Responses of human mechanoreceptive afferents to embossed dot arrays scanned across fingerpad skin. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.12-03-00827.1992
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.