CoChat

Tactile sensibility in the human hand: receptive field characteristics of mechanoreceptive units in the glabrous skin area

Open access
Johansson, R S · 1978 · The Journal of Physiology

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Abstract

1. Impulses in tactile units innervating the glabrous skin of the hand recorded from the median nerve of adult human subjects. The recording electrodes which were made of tungsten were inserted percutaneously in the upper arm. 2. The units were classified on the basis of their sensitivity to sustained identation and to remote stimuli. Two types of rapidly adapting units and two types of slowly adapting units were found. In accordance with earlier reports they were denoted RA and PC units, and SA I and SA II units. 3. The sensitivity profiles of the receptive fields were analysed by measuring the extent of the receptive field as a function of the identation amplitude. 4. The RA and SA I units had receptive fields with several zones of maximal sensitivity distributed over an approximately circular or oval area typically covering five to ten papillary ridges. Within this area the sensitivity was high, whereas the sensitivity diminished steeply with increasing distance from this area. 5. The PC and SA II units had receptive fields with a single zone of maximal sensitivity and gentle continuous threshold increase outside this zone. 6. The relation between the identation amplitude and the receptive field size of a unit was described by a power function. The power exponent for the RA and SA I units was well below unity, whereas the PC and SA II units had exponenets greater than unity. The variation in exponent was very small among the RA and among the SA I units. Their average exponents were therefore regarded as characteristics of the unit type. 7. The SA II units were qualitatively studied with regard to their sensitivity to lateral skin stretch. Three different types of SA II units were described with regard to the directional pattern of this sensitivity. 8. The relation of the present findings to the problem of correlation between morphological structures of nerve end‐organs and physiologically defined unit types is considered. 9. Moreover, the findings, indicate that the RA and SA I units are well suited for the analysis of mechanical events on the skin surface with a high degree of spatial selectivity, whereas the PC and SA II units are suited for analysis of other mechanical events, e.g. vibration and various forms of tension in the skin and related tissues.

Overview

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1978.sp012411

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 35 references

Cited by

See all 430

Metadata

Authors
Johansson, R. S.
Corresponding author
Johansson, R S
Venue
The Journal of Physiology
Publisher
Wiley
Published
1978-08
Volume
281
Issue
1
Pages
101-125
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2012619381
Cited by
430
References
35
Citations by year
2026: 9 · 2025: 13 · 2024: 10 · 2023: 10 · 2022: 10 · 2021: 13 · 2020: 16 · 2019: 7 · 2018: 14 · 2017: 11 · 2016: 11 · 2015: 16 · 2014: 13 · 2013: 9 · 2012: 20
FWCI
4.75
Type
journal article
Language
en
Open access
Locations
  • The Journal of Physiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Life Sciences › Neuroscience › Sensory Systems › Ion Channels and Receptors
Keywords
tactile sensitivity, mechanoreceptors, receptive fields, glabrous skin, hand, power function, median nerve, spatial selectivity
MeSH terms
Action Potentials, Adult, Female, Hand, Humans, Male, Mechanoreceptors, Skin, Touch

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tactile sensibility in the human hand: receptive field characteristics of mechanoreceptive units in the glabrous skin area. https://app.cochat.ai/papers/10.1113/jphysiol.1978.sp012411
The paper
Johansson, R. S. (1978). Tactile sensibility in the human hand: receptive field characteristics of mechanoreceptive units in the glabrous skin area. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1978.sp012411

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.