Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 184

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Dark Light, Rod Saturation, and the Absolute and Incremental Sensitivity of Mouse Cone Vision

Open access
Naarendorp, Frank, Esdaille, Tricia M., Banden, Serenity M., Andrews-Labenski, John, Gross, Owen P., Pugh, Edward N. · 2010 · The Journal of Neuroscience

Abstract

Visual thresholds of mice for the detection of small, brief targets were measured with a novel behavioral methodology in the dark and in the presence of adapting lights spanning ∼8 log 10 units of intensity. To help dissect the contributions of rod and cone pathways, both wild-type mice and mice lacking rod ( Gnat1 −/− ) or cone ( Gnat2 cpfl3 ) function were studied. Overall, the visual sensitivity of mice was found to be remarkably similar to that of the human peripheral retina. Rod absolute threshold corresponded to 12–15 isomerized pigment molecules ( R *) in image fields of 800 to 3000 rods. Rod “dark light” (intrinsic retinal noise in darkness) corresponded to that estimated previously from single-cell recordings, 0.012 R * s −1 rod −1 , indicating that spontaneous thermal isomerizations are responsible. Psychophysical rod saturation was measured for the first time in a nonhuman species and found to be very similar to that of the human rod monochromat. Cone threshold corresponded to ∼5 R * cone −1 in an image field of 280 cones. Cone dark light was equivalent to ∼5000 R * s −1 cone −1 , consistent with primate single-cell data but 100-fold higher than predicted by recent measurements of the rate of thermal isomerization of mouse cone opsins, indicating that nonopsin sources of noise determine cone threshold. The new, fully automated behavioral method is based on the ability of mice to learn to interrupt spontaneous wheel running on the presentation of a visual cue and provides an efficient and highly reliable means of examining visual function in naturally behaving normal and mutant mice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1523/jneurosci.2186-10.2010

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 184

Metadata

Authors
Naarendorp, F., Esdaille, T. M., Banden, S. M., Andrews-Labenski, J., Gross, O. P., & Pugh, E. N.
Venue
The Journal of Neuroscience
Published
2010-09-15
Volume
30
Issue
37
Pages
12495-12507
ISSN
  • 0270-6474 (ISSN-L)
  • 1529-2401
OpenAlex
W2013870510
Cited by
184
References
2
FWCI
4.71
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dark Light, Rod Saturation, and the Absolute and Incremental Sensitivity of Mouse Cone Vision. https://app.cochat.ai/papers/10.1523/jneurosci.2186-10.2010
The paper
Naarendorp, F., Esdaille, T. M., Banden, S. M., Andrews-Labenski, J., Gross, O. P., & Pugh, E. N. (2010). Dark Light, Rod Saturation, and the Absolute and Incremental Sensitivity of Mouse Cone Vision. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.2186-10.2010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.