The DOI matches its Crossref record.
Optical Recording of Action Potentials with Second-Harmonic Generation Microscopy
Open accessAbstract
Nonlinear microscopy has proven to be essential for neuroscience investigations of thick tissue preparations. However, the optical recording of fast (∼1 msec) cellular electrical activity has never until now been successfully combined with this imaging modality. Through the use of second-harmonic generation microscopy of primary Aplysia neurons in culture labeled with 4-[4-(dihexylamino)phenyl][ethynyl]-1-(4-sulfobutyl)pyridinium (inner salt), we optically recorded action potentials with 0.833 msec temporal and 0.6 μm spatial resolution on soma and neurite membranes. Second-harmonic generation response as a function of change in membrane potential was found to be linear with a signal change of ∼6%/100 mV. The signal-to-noise ratio was ∼1 for single-trace action potential recordings but was readily increased to ∼6–7 with temporal averaging of ∼50 scans. Photodamage was determined to be negligible by observing action potential characteristics, cellular resting potential, and gross cellular morphology during and after laser illumination. High-resolution (micrometer scale) optical recording of membrane potential activity by previous techniques has been limited to imaging depths an order of magnitude less than nonlinear methods. Because second-harmonic generation is capable of imaging up to ∼400 μm deep into intact tissue with submicron resolution and little out-of-focus photodamage or bleaching, its ability to record fast electrical activity should prove valuable to future electrophysiology studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure
Chen, X., Nadiarynkh, O., Plotnikov, S., & Campagnola, P. J. (2012) · Nature Protocols · doi:10.1038/nprot.2012.009 · Cited by 985
Debanne, D., Campanac, E., Bialowas, A., Carlier, E., & Alcaraz, G. (2011) · Physiological Reviews · doi:10.1152/physrev.00048.2009 · Cited by 571
Electrophysiology in the age of light
Scanziani, M., & Häusser, M. (2009) · Nature · doi:10.1038/nature08540 · Cited by 468
Nanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K., Donoghue, J. P., Fraser, S. E., Lippincott-Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 356
Metadata
- Authors
- Dombeck, D. A., Blanchard-Desce, M., & Webb, W. W.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 2004-01-28
- Volume
- 24
- Issue
- 4
- Pages
- 999-1003
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W2121963608
- Cited by
- 166
- References
- 0
- FWCI
- 10.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical Recording of Action Potentials with Second-Harmonic Generation Microscopy. https://app.cochat.ai/papers/10.1523/jneurosci.4840-03.2004
- The paper
- Dombeck, D. A., Blanchard-Desce, M., & Webb, W. W. (2004). Optical Recording of Action Potentials with Second-Harmonic Generation Microscopy. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.4840-03.2004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.