Ionic Determinants of Functional Reentry in a 2-D Model of Human Atrial Cells During Simulated Chronic Atrial Fibrillation
Open accessAbstract
Recent studies suggest that atrial fibrillation (AF) is maintained by fibrillatory conduction emanating from a small number of high-frequency reentrant sources (rotors). Our goal was to study the ionic correlates of a rotor during simulated chronic AF conditions. We utilized a two-dimensional (2-D), homogeneous, isotropic sheet (5 x 5 cm(2)) of human atrial cells to create a chronic AF substrate, which was able to sustain a stable rotor (dominant frequency approximately 5.7 Hz, rosette-like tip meander approximately 2.6 cm). Doubling the magnitude of the inward rectifier K(+) current (I(K1)) increased rotor frequency ( approximately 8.4 Hz), and reduced tip meander (approximately 1.7 cm). This rotor stabilization was due to a shortening of the action potential duration and an enhanced cardiac excitability. The latter was caused by a hyperpolarization of the diastolic membrane potential, which increased the availability of the Na(+) current (I(Na)). The rotor was terminated by reducing the maximum conductance (by 90%) of the atrial-specific ultrarapid delayed rectifier K(+) current (I(Kur)), or the transient outward K(+) current (I(to)), but not the fast or slow delayed rectifier K(+) currents (I(Kr)/I(Ks)). Importantly, blockade of I(Kur)/I(to) prolonged the atrial action potential at the plateau, but not at the terminal phase of repolarization, which led to random tip meander and wavebreak, resulting in rotor termination. Altering the rectification profile of I(K1) also slowed down or abolished reentrant activity. In combination, these simulation results provide novel insights into the ionic bases of a sustained rotor in a 2-D chronic AF substrate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nattel, S., Maguy, A., Le Bouter, S., & Yeh, Y.-H. (2007) · Physiological Reviews · doi:10.1152/physrev.00014.2006 · Cited by 858
Self-citationAtrial Fibrillation Pathophysiology: Implications for Management
Iwasaki, Y.-K., Nishida, K., Kato, T., & Nattel, S. (2011) · Circulation · doi:10.1161/circulationaha.111.019893 · Cited by 852
Self-citationRole of the Autonomic Nervous System in Atrial Fibrillation: Pathophysiology and Therapy
Chen, P.-S., Chen, L. S., Fishbein, M. C., Lin, S.-F., & Nattel, S. (2014) · Circulation Research · doi:10.1161/circresaha.114.303772 · Cited by 790
Self-citationAtrial Remodeling and Atrial Fibrillation
Nattel, S., & Harada, M. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.555 · Cited by 736
Self-citationHeijman, J., Voigt, N., Nattel, S., & Dobrev, D. (2014) · Circulation Research · doi:10.1161/circresaha.114.302226 · Cited by 677
Self-citation
Metadata
- Authors
- Pandit, S. V., Berenfeld, O., Anumonwo, J. M. B., Zaritski, R. M., Kneller, J., Nattel, S., & Jalife, J.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2005-06
- Volume
- 88
- Issue
- 6
- Pages
- 3806-3821
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1967494220
- Cited by
- 247
- References
- 0
- FWCI
- 6.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionic Determinants of Functional Reentry in a 2-D Model of Human Atrial Cells During Simulated Chronic Atrial Fibrillation. https://app.cochat.ai/papers/10.1529/biophysj.105.060459
- The paper
- Pandit, S. V., Berenfeld, O., Anumonwo, J. M. B., Zaritski, R. M., Kneller, J., Nattel, S., & Jalife, J. (2005). Ionic Determinants of Functional Reentry in a 2-D Model of Human Atrial Cells During Simulated Chronic Atrial Fibrillation. Biophysical Journal. https://doi.org/10.1529/biophysj.105.060459
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.