Cited by 65Corneal surgery and disordersOptical Imaging and Spectroscopy TechniquesCorneal Surgery and Treatments

Light transmission in the human cornea as a function of position across the ocular surface: theoretical and experimental aspects

Open access
Doutch, James, Quantock, Andrew J., Smith, Valerie A., Meek, Keith M.·2008·Biophysical Journal

Abstract

This article investigates the theoretical basis for differences in visible light transmission through the human cornea as a function of distance from the center. Experimentally, transmission decreases approximately linearly up to 3 mm from the central axis, then quadratically beyond this. It is known that collagen fibril number density and collagen fibril radii change from the central region to the corneal periphery. We modeled, using the direct-summation-of-scattered-fields method, the effects these ultrastructural changes would be expected to have on light transmission, accounting for the increase in corneal thickness from center to edge. Fibril positions for the modeling were obtained from electron micrographs of human cornea. Theoretically, transmission remains fairly constant across the central cornea; then, as the fibril diameter increases, the predicted scattering increases. Interfibrillar spacing changes alter the refractive index ratio between matrix and fibril; this was modeled in our theoretical deductions. Fibril number density had a minimal effect on light propagation. Our theoretical deductions were in broad agreement with our experimental data. It is concluded that the reduced transparency in the peripheral stroma is primarily caused by changes in fibril radius and an increase in refractive index ratio between the fibril and the interfibrillar substance.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1529/biophysj.108.132316

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The decrease in transmittance outside the central 4 mm pre-pupillary cornea is attributed to the increase in fibril radius that occurs in the periphery of the cornea.

    “Theoretical calculations of light transmission (Doutch et al., 2008) attributed this to the increase in fibril radius that occurs in the periphery of the cornea (Boote et al., 2003).”

    From Corneal structure and transparency (2015) · cites this paper as Doutch et al., 2008

    The Discussion and “Modeling transmission in the human cornea” attribute increased peripheral scattering to larger fibrils, supporting the main attribution. The paper does not establish the claimed central 4 mm boundary: the Discussion calls the prepupillary zone approximately 3 mm in diameter, while the modeling section describes it as extending about 3 mm from the optical center. Its conclusion also identifies a change in refractive-index ratio as a contributor. (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 7

  1. [9]9. McCally, R. L., and R. A. Farrell. 1990. Light scattering from cornea and corneal transparency. In Non-Invasive Diagnostic Techniques in Ophthalmology. B. R. Masters, editor. Springer, New York.
  2. [16]16. Feuk, T. 1970. On the transparency of the stroma in the mammalian cornea. IEEE Trans. Biomed. Eng. 17:186-190.
  3. [17]17. Farrell, R. A., and R. L. McCally. 2000. Corneal transparency. In Principles and Practice of Ophthalmology. D. M. Albert and F. A. Jakobiec, editors. WB Saunders. Philadelphia, PA.
  4. [18]18. Khlebtsov, N. G., I. L. Maksimova, V. V. Tuchin, and L. Wang. 2002. Introduction to light scattering by biological objects. In Handbook of Optical Biomedical Diagnostics. V. V. Tuchin, editor. SPIE Press, Washington, DC.
  5. [37]37. Doutch, J., A. J. Quantock, and K. Meek. 2007. Changes in visible light transmission across the corneal stroma. Proc. SPIE 65350V.
  6. [38]38. Leonard, D. 1996. The Ultrastructure of the Corneal Stroma and its Implications for Transparency. Open University, Oxford, UK.
  7. [41]41. Meek, K. M. 2002. The Cornea. In Signals and Perception. D. Roberts, editor. Palgrave Macmillan, Basingstoke and New York.

Cited by

Sorted by citations

Authors
Doutch, J., Quantock, A. J., Smith, V. A., & Meek, K. M.
Affiliations
  • Cardiff University (GB)
  • University of Bristol (GB)
Corresponding author
Meek, Keith M.
Venue
Biophysical Journal
Publisher
Elsevier BV
Published
2008-12
Volume
95
Issue
11
Pages
5092-5099
ISSN
0006-3495 (ISSN-L)
OpenAlex
W2155177190
Cited by
65
References
1
Citations by year
2026: 6 · 2025: 4 · 2024: 4 · 2023: 6 · 2022: 1 · 2021: 4 · 2020: 4 · 2019: 2 · 2018: 2 · 2017: 3 · 2016: 3 · 2015: 5 · 2014: 5 · 2013: 3 · 2012: 3
FWCI
2.56
Type
journal article
Language
en
Open access
Locations
  • Biophysical Journal (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • ORCA Online Research @Cardiff (Cardiff University) (acceptedVersion)
Funders
Medical Research Council
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
Keywords
corneal stroma, collagen fibrils, fibril diameter, refractive index ratio, corneal periphery, light scattering, corneal thickness, corneal ultrastructure
MeSH terms
Cornea, Humans, Models, Biological, Surface Properties, Vision, Ocular, Limbus Corneae

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review