CoChat

Technical details influence the diagnostic accuracy of the 1 μg ACTH stimulation test

Open access
Wade, Matthew, Baid, Smita, Calis, Karim, Raff, Hershel, Sinaii, Ninet, Nieman, Lynnette · 2010 · European Journal of Endocrinology

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To examine the factors causing inadequate cortisol responses to the 1 microg ACTH stimulation test. DESIGN: Random test assignment (by age and gender) at 0800 or 1600 h. METHODS: We recruited 20 healthy adults to each of the three age groups (<40 years, 40-55 years, and >55 years; half females in each group). ACTH stimulation tests were performed in an outpatient clinic at the NIH Clinical Research Center. Plasma cortisol was measured just before, and 30 and 60 min after the administration of 1 microg ACTH (1-24). The ACTH concentration in diluted and administered solutions was measured. RESULTS: Twenty-five volunteers (19 at 1600 h) had a subnormal cortisol response (peak cortisol 10.4-17.5 microg/dl), using a criterion <18 microg/dl (497 nmol/l), for a specificity of 58% (confidence interval (CI) 45-71%). Afternoon testing had a significant impact on failure rates (odds ratio 6.98, CI 2.17-22.43), while gender and age did not. The stock solution contained 1 microg ACTH, but after administration through tubing it contained only 0.5-0.8 microg. CONCLUSIONS: The high rate of abnormal results, especially in the afternoon, and loss of ACTH through tubing suggest that morning testing and minimal tubing should be adopted to avoid an inappropriate diagnosis of adrenal insufficiency. Earlier time points and standardized protocols would facilitate comparison of studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1530/eje-09-0746

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Research works printed but not linked: 6

  1. 1965, Lancet, 191, 243
  2. Nieman, 2003, Journal of endocrinological investigation, 26, 74
  3. Mayenknecht, 1998, Journal of Clinical Endocrinology & Metabolism, 83, 1558, 10.1210/jc.83.5.1558 · doi:10.1210/jc.83.5.1558 · Paper page
  4. 2002, HONG KONG MEDICAL JOURNAL, 8, 427
  5. Cohen, 1996, Journal of Clinical Endocrinology & Metabolism, 81, 3129, 10.1210/jc.81.8.3129 · doi:10.1210/jc.81.8.3129
  6. Grinspoon, 1994, Journal of Clinical Endocrinology & Metabolism, 79, 923, 10.1210/jc.79.4.923 · doi:10.1210/jc.79.4.923 · Paper page

Cited by

See all 83

Metadata

Authors
Wade, M., Baid, S., Calis, K., Raff, H., Sinaii, N., & Nieman, L.
Affiliations
  • National Institutes of Health (US)
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (US)
  • Medical College of Wisconsin (US)
  • National Institutes of Health Clinical Center (US)
Corresponding author
Nieman, Lynnette
Venue
European Journal of Endocrinology
Published
2010-01
Volume
162
Issue
1
Pages
109-113
ISSN
  • 0804-4643 (ISSN-L)
  • 1479-683X
OpenAlex
W2103980703
Cited by
83
References
34
Citations by year
2026: 2 · 2025: 2 · 2024: 2 · 2023: 6 · 2022: 5 · 2021: 7 · 2020: 3 · 2019: 10 · 2018: 4 · 2017: 3 · 2016: 5 · 2015: 5 · 2014: 5 · 2013: 7 · 2012: 5
FWCI
4.11
Type
journal article
Language
en
Open access
Locations
  • European Journal of Endocrinology (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (ZIAHD008831)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
Keywords
cortisol response, adrenal insufficiency, test timing, diagnostic accuracy, healthy volunteers, test procedure standardization
MeSH terms
Adrenal Insufficiency, Adrenocorticotropic Hormone, Adult, Aged, Diagnostic Errors, Diagnostic Tests, Routine, Female, Humans, Hydrocortisone, Male, Middle Aged, Reference Values, Sensitivity and Specificity, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Technical details influence the diagnostic accuracy of the 1 μg ACTH stimulation test. https://app.cochat.ai/papers/10.1530/eje-09-0746
The paper
Wade, M., Baid, S., Calis, K., Raff, H., Sinaii, N., & Nieman, L. (2010). Technical details influence the diagnostic accuracy of the 1 μg ACTH stimulation test. European Journal of Endocrinology. https://doi.org/10.1530/eje-09-0746

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.