Mass spectrometry and immunoassay: how to measure steroid hormones today and tomorrow
The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
Summary: The recent onslaught of mass spectrometry (MS) to measurements of steroid hormones, including demands that they should be the only acceptable method, has confused clinicians and scientists who have relied for more than 40 years on a variety of immunoassay (IA) methods in steroid hormone measurements. There is little doubt that MS methods with their superior specificity will be the future method of choice in many clinical and research applications of steroid hormone measurement. However, the majority of steroid measurements are currently, and will continue to be, carried out using various types of IAs for several reasons, including their technical ease, cost and availability of commercial reagents. Speedy replacement of all IAs with MS is an unrealistic and unnecessary goal, because the availability of MS measurements is limited by cost, need of expensive equipment, technical demands and lack of commercial applications. Furthermore, IAs have multiple well-known advantages that vindicate their continuing use. The purpose of this article is to elucidate the advantages and limitations of the MS and IA techniques from two angles, i.e. promotion of MS and defence of IA. The purpose of the text is to give the reader an unbiased view about the current state and future trends of steroid analysis and to help him/her choose the correct assay method to serve his/her diagnostic and research needs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Steroids must be measured by mass spectrometric methods to comply with current quality standards [3,4].”
In the citing paper
“Sensitive liquid-chromatography-tandemmass-spectrometry (LC-MS/MS) methods meet many of these re quirements and have been accepted as the-state-of-the-art methods for quantitative analysis of steroid hormones in serum [3,4].”
In the citing paper
“Commonly used cortisol immunoassays provide variable results and require individual reference ranges; therefore, LC-MS/MS assays are now considered the reference standard for measuring levels of glucocorticoids in biologic fluids.28”
From Home waking salivary cortisone to screen for adrenal insufficiency (2023) · cites this paper as [28]
In the citing paper
“LC-MS/MS techniques are more expensive and time consuming, but carry advantages of high sensitivity and specificity and the possibility of simultaneous measurement of salivary cortisol and cortisone [8,9].”
From Salivary cortisol and cortisone in diagnosis of Cushing's syndrome: a comparison of six different analytical methods (2023) · cites this paper as [8]
In the citing paper
“LC-MS/MS techniques are more expensive and time consuming, but carry advantages of high sensitivity and specificity and the possibility of simultaneous measurement of salivary cortisol and cortisone [8,9].”
From Salivary cortisol and cortisone in diagnosis of Cushing's syndrome: a comparison of six different analytical methods (2023) · cites this paper as [8]
Citations
Cites
Rosner, W., Auchus, R. J., Azziz, R., Sluss, P. M., & Raff, H. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-1864 · Cited by 1,176
Assay of Plasma Insulin in Human Subjects by Immunological Methods
YALOW, R. S., & BERSON, S. A. (1959) · Nature · doi:10.1038/1841648b0 · Cited by 1,098
Solid-Phase Radioimmunoassay of Estradiol-17β
ABRAHAM, G. E. (1969) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-29-6-866 · Cited by 836
Osteoporosis in Men: An Endocrine Society Clinical Practice Guideline
Watts, N. B., Adler, R. A., Bilezikian, J. P., Drake, M. T., Eastell, R., Orwoll, E. S., & Finkelstein, J. S. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-3045 · Cited by 611
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Urine steroid metabolomics as a biomarker tool for detecting malignancy in adrenal tumors
Arlt, W., Biehl, M., Taylor, A. E., Hahner, S., Libé, R., Hughes, B. A., Schneider, P., Smith, D. J., Stiekema, H., Krone, N., et al. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-1565 · Cited by 458
Self-citationKrone, N., Hughes, B. A., Lavery, G. G., Stewart, P. M., Arlt, W., & Shackleton, C. H. L. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.04.010 · Cited by 434
Challenges to the measurement of estradiol: an Endocrine Society Position Statement
Rosner, W., Hankinson, S. E., Sluss, P. M., Vesper, H. W., & Wierman, M. E. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-3780 · Cited by 408
A longitudinal study of plasma and urinary cortisol in pregnancy and postpartum
Jung, C., Ho, J. T., Torpy, D. J., Rogers, A., Doogue, M., Lewis, J. G., Czajko, R. J., & Inder, W. J. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2395 · Cited by 394
Estrogen levels in childhood determined by an ultrasensitive recombinant cell bioassay.
Klein, K. O., Baron, J., Colli, M. J., McDonnell, D. P., & Cutler, G. B. (1994) · Journal of Clinical Investigation · doi:10.1172/jci117616 · Cited by 377
Cited by
Items 301–319 of 319
Gazárková, T., Plachká, K., Vlčková, H., & Nováková, L. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.344903
Нагорна, В., Sencha-Hlevatska, K. V., Fehr, D., Bonmarin, M., Korobeynikov, G., Mytko, A., & Lorenzetti, S. (2026) · Zürcher Hochschule für Angewandte Wissenschaften digital collection (Zurich University of Applied Sciences) · doi:10.21256/zhaw-34890
Shao, S., Nan, L., Liu, R., Zhang, Y., Pan, Y., Wen, K., Yu, X., Shen, J., & Wang, Z. (2026) · Analytical Letters · doi:10.1080/00032719.2026.2615056
“…In contrast, immunoassays based on antibodies such as enzyme-linked immunosorbent assay (ELISA) and lateral flow immunochromatography assay (LFIA) offer rapid, cost-effective alternatives suitable for high-throughput and field testing (Taylor, Keevil, and Huhtaniemi 2015; Wang et al. 2024).”
Srivastava, N., Kaur, C., Mane, A. V., Singh, G., & Kumar, R. (2026) · Reference series in phytochemistry · doi:10.1007/978-3-031-69044-0_13-1
Zhang, C., Ye, M., Marzullo, B. J., Adler, H. J., & Hu, B. H. (2026) · Biology of Sex Differences · doi:10.1186/s13293-026-00871-3
“Because LC-MS is widely regarded as the most reliable method for steroid hormone analysis [93] and because Wall et al. included multiple daily sampling time points, we used their findings to guide our data interpretation.”
Stéroïdomique corticosurrénalienne par LC-MS/MS : applications en endocrinologie pédiatrique
Travers, S. A. A. (2020) · theses.fr (ABES) · doi:10.70675/84cf9c3bze93ez41dcza251z559f27f3c6a6
Gao, Y., Zhang, Y., Meng, X., Xu, R., Liu, H., Yao, H., & Gong, J. (2026) · Journal of Chromatography A · doi:10.1016/j.chroma.2026.466980 · Cited by 1
Engman, V., Lamon, S., & Mason, S. A. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.05.12.724720
Sachit, B. A., Dass, S. A., Rajan, R. S., Tye, G. J., & Balakrishnan, V. (2026) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2026.152755
Engman, V., Lamon, S., & Mason, S. A. (2026) · Steroids · doi:10.1016/j.steroids.2026.109823
Diagnostic work-up in paediatric adrenocortical tumours: an international consensus
Antonini, S. R. R., Wiegering, V., Halah, M. P., Pinto, L. E. C., Atapattu, N., Md, P., Elias Jr., J., Eker, N., Faßnacht, M., Fragoso, M. C. B. V., et al. (2026) · European Journal of Endocrinology · doi:10.1093/ejendo/lvag086
Expanding the Measurement Space of Ion Mobility-Mass Spectrometry Using Chemical Derivatizations
Fernandez, S., Acateca, A., Garrison, B. B., Sabatini, H. M., & Chouinard, C. D. (2026) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.6c00210
Tan, C., Chen, Z., Lin, J., Zhang, Y., Su, X., Yu, X., Cai, Z., Wang, L., Lei, S., Yan, Y., et al. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c04260
Ye, T., Zhang, W., Jing, R., & Wang, J. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7300701
Etablierung und Validierung einer LC-MS/MS-basierten Bestimmung von 17-Hydroxyprogesteron beim Hund
Naczenski, S., Klein, R., & Hildebrand, A. (2026) · Tierärztliche Praxis Ausgabe K Kleintiere / Heimtiere · doi:10.1055/a-2854-7332
“Die LC-MS/MS-Technologie ist in der humanmedizinischen Steroid-hormonanalytik etabliert und zeichnet sich durch eine hohe ana-lytische Spezifität und Standardisierbarkeit aus [3, 11, 12].”
Serres-Gómez, M., González‐Casaus, M. L., Olmedo, M., Fernández–Calle, P., Torrubiano, D. V., Iturzaeta, J. M., Almodóvar, B. G., & Soto, A. B. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121312
Vibhatavata, P., Liu, Y., Almeida, M. Q., Amar, L., Bancos, I., Baron, S., Butz, F., Cohen, D. L., Culver, S. A., Fernandes-Rosa, F. L., et al. (2026) · Hypertension · doi:10.1161/hypertensionaha.126.27798
Hommen, J. A., Eberwein, T., Vogkou, C. T., Albeiruty, S., Muchalla, M., & Schott, M. (2026) · Hormone and Metabolic Research · doi:10.1055/a-2976-3465
Metadata
- Authors
- Taylor, A. E., Keevil, B., & Huhtaniemi, I. T.
- Affiliations
- University of Turku (FI)
- Corresponding author
- Keevil, Brian
- Huhtaniemi, Ilpo T
- Venue
- European Journal of Endocrinology
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-08
- Volume
- 173
- Issue
- 2
- Pages
- D1-D12
- ISSN
- 0804-4643 (ISSN-L)
- 1479-683X
- OpenAlex
- W2110473840
- Cited by
- 320
- References
- 74
- Citations by year
- 2026: 20 · 2025: 23 · 2024: 31 · 2023: 42 · 2022: 35 · 2021: 33 · 2020: 27 · 2019: 33 · 2018: 32 · 2017: 26 · 2016: 15 · 2015: 3
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Journal of Endocrinology (publishedVersion)
- PubMed (publishedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- steroid hormones, mass spectrometry, immunoassay, steroid hormone measurement, method comparison
- MeSH terms
- Animals, Chromatography, Liquid, Hormones, Humans, Immunoassay, Mass Spectrometry, Steroids, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.