Mass spectrometry and immunoassay: how to measure steroid hormones today and tomorrow
The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
Summary: The recent onslaught of mass spectrometry (MS) to measurements of steroid hormones, including demands that they should be the only acceptable method, has confused clinicians and scientists who have relied for more than 40 years on a variety of immunoassay (IA) methods in steroid hormone measurements. There is little doubt that MS methods with their superior specificity will be the future method of choice in many clinical and research applications of steroid hormone measurement. However, the majority of steroid measurements are currently, and will continue to be, carried out using various types of IAs for several reasons, including their technical ease, cost and availability of commercial reagents. Speedy replacement of all IAs with MS is an unrealistic and unnecessary goal, because the availability of MS measurements is limited by cost, need of expensive equipment, technical demands and lack of commercial applications. Furthermore, IAs have multiple well-known advantages that vindicate their continuing use. The purpose of this article is to elucidate the advantages and limitations of the MS and IA techniques from two angles, i.e. promotion of MS and defence of IA. The purpose of the text is to give the reader an unbiased view about the current state and future trends of steroid analysis and to help him/her choose the correct assay method to serve his/her diagnostic and research needs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Steroids must be measured by mass spectrometric methods to comply with current quality standards [3,4].”
In the citing paper
“Sensitive liquid-chromatography-tandemmass-spectrometry (LC-MS/MS) methods meet many of these re quirements and have been accepted as the-state-of-the-art methods for quantitative analysis of steroid hormones in serum [3,4].”
In the citing paper
“Commonly used cortisol immunoassays provide variable results and require individual reference ranges; therefore, LC-MS/MS assays are now considered the reference standard for measuring levels of glucocorticoids in biologic fluids.28”
From Home waking salivary cortisone to screen for adrenal insufficiency (2023) · cites this paper as [28]
In the citing paper
“LC-MS/MS techniques are more expensive and time consuming, but carry advantages of high sensitivity and specificity and the possibility of simultaneous measurement of salivary cortisol and cortisone [8,9].”
From Salivary cortisol and cortisone in diagnosis of Cushing's syndrome: a comparison of six different analytical methods (2023) · cites this paper as [8]
In the citing paper
“LC-MS/MS techniques are more expensive and time consuming, but carry advantages of high sensitivity and specificity and the possibility of simultaneous measurement of salivary cortisol and cortisone [8,9].”
From Salivary cortisol and cortisone in diagnosis of Cushing's syndrome: a comparison of six different analytical methods (2023) · cites this paper as [8]
Citations
Cites
Rosner, W., Auchus, R. J., Azziz, R., Sluss, P. M., & Raff, H. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-1864 · Cited by 1,176
Assay of Plasma Insulin in Human Subjects by Immunological Methods
YALOW, R. S., & BERSON, S. A. (1959) · Nature · doi:10.1038/1841648b0 · Cited by 1,098
Solid-Phase Radioimmunoassay of Estradiol-17β
ABRAHAM, G. E. (1969) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-29-6-866 · Cited by 836
Osteoporosis in Men: An Endocrine Society Clinical Practice Guideline
Watts, N. B., Adler, R. A., Bilezikian, J. P., Drake, M. T., Eastell, R., Orwoll, E. S., & Finkelstein, J. S. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-3045 · Cited by 611
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Urine steroid metabolomics as a biomarker tool for detecting malignancy in adrenal tumors
Arlt, W., Biehl, M., Taylor, A. E., Hahner, S., Libé, R., Hughes, B. A., Schneider, P., Smith, D. J., Stiekema, H., Krone, N., et al. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-1565 · Cited by 458
Self-citationKrone, N., Hughes, B. A., Lavery, G. G., Stewart, P. M., Arlt, W., & Shackleton, C. H. L. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.04.010 · Cited by 434
Challenges to the measurement of estradiol: an Endocrine Society Position Statement
Rosner, W., Hankinson, S. E., Sluss, P. M., Vesper, H. W., & Wierman, M. E. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-3780 · Cited by 408
A longitudinal study of plasma and urinary cortisol in pregnancy and postpartum
Jung, C., Ho, J. T., Torpy, D. J., Rogers, A., Doogue, M., Lewis, J. G., Czajko, R. J., & Inder, W. J. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2395 · Cited by 394
Estrogen levels in childhood determined by an ultrasensitive recombinant cell bioassay.
Klein, K. O., Baron, J., Colli, M. J., McDonnell, D. P., & Cutler, G. B. (1994) · Journal of Clinical Investigation · doi:10.1172/jci117616 · Cited by 377
Cited by
Items 101–200 of 319
Hormonal contraceptives as disruptors of competitive behavior: Theoretical framing and review
Arthur, L. C., Casto, K. V., & Blake, K. R. (2022) · Frontiers in Neuroendocrinology · doi:10.1016/j.yfrne.2022.101015 · Cited by 20
Hamidovic, A., Davis, J. M., Soumare, F., Naveed, A., Ghani, Y., Semiz, S., Khalil, D., & Wardle, M. C. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12041553 · Cited by 19
Casals, G., Ferrer, R., Urgell, E., Escobar-Morreale, H. F., Argente, J., Sesmilo, G., & Biagetti, B. (2023) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2023-0020 · Cited by 32
“Some studies have demonstrated that free testosterone correlates betterwith the clinical presentation of the polycystic ovary syndrome than total testosterone [42, 43].”
BackgroundTowards Improved Steroid Hormone Analysis: The Shift from Immunoassays to Mass Spectrometry
Deng, B., Bi, M., Zheng, Y., Hussain, D., Yang, S., & Chen, D. (2024) · Journal of Analysis and Testing · doi:10.1007/s41664-024-00326-x · Cited by 23
Khera, M., Torres, L. O., Grober, E. D., Morgentaler, A., Miner, M. M., Jones, T. H., Mills, J. N., & Salonia, A. (2025) · Sexual Medicine Reviews · doi:10.1093/sxmrev/qeaf036 · Cited by 26
Morphologic alterations of the fear circuitry: the role of sex hormones and oral contraceptives
Brouillard, A., Davignon, L., Turcotte, A.-M., & Marin, M. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1228504 · Cited by 24
“…to nearly 20% and was the result of a high non-detection rate using LC-MS/MS. Importantly, LC-MS/MS provides better assay validity than immunoassay methods for salivary E2 and P (especially for low ranges) and is on its way to becoming the gold standard in endocrine measurement (196 – 199).”
MethodZhang, J., Chen, Q., Wang, L., Chen, K., Mu, W., Duan, C., & Li, X. (2020) · Journal of Applied Toxicology · doi:10.1002/jat.3983 · Cited by 17
Hormonal and modality specific effects on males’ emotion recognition ability
Lausen, A., Broering, C., Penke, L., & Schacht, A. (2020) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2020.104719 · Cited by 17
LC-MSMS assays of urinary cortisol, a comparison between four in-house assays
Brossaud, J., Leban, M., Corcuff, J., de Casson, F. B., Loupp, A.-G. L., Masson, D., Moal, V., & Bach‐Ngohou, K. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0806 · Cited by 17
Li, Y., Yan, Z., Li, X., Yin, X., & Li, K. (2021) · Molecules · doi:10.3390/molecules26206213 · Cited by 17
Brand, B. A., de Boer, J. N., Willemse, E. J. M., Weickert, C. S., Sommer, I. E., & Weickert, T. W. (2024) · Archives of Women s Mental Health · doi:10.1007/s00737-024-01491-9 · Cited by 19
“These concerns are suggested to become specifically problematic when expected levels of estrogens fall below 70 pmol/L (Taylor et al. 2015), whereas premenopausal women typically have estrogen levels above this threshold (Verdonk et al. 2019), and in our sample, only a small proportion of women had…”
Relative hyperestrogenism in Klinefelter Syndrome: results from a meta-analysis
Santi, D., Vincentis, S. D., Scaltriti, S., & Rochira, V. (2019) · Endocrine · doi:10.1007/s12020-019-01850-y · Cited by 21
do Amaral, J. M. X., Deslandes, A. C., Padilha, M. C., Neto, L. V., Osorio, L. E., Neto, F. R. D. A., & Cruz, M. S. (2022) · Drug Testing and Analysis · doi:10.1002/dta.3230 · Cited by 20
Urge, A. Y., Pampanin, D. M., Martino, M. E., Knudsen, D. L., & Brede, C. (2023) · Separations · doi:10.3390/separations10040240 · Cited by 15
Kanegusuku, A. G., Araque, K., Nguyen, H., Wei, B., Hosseini, S., & Soldin, S. J. (2021) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/2042018821989240 · Cited by 15
Novel methods in adrenal research: a metabolomics approach
Papathomas, T. G., Sun, N., Chortis, V., Taylor, A. E., Arlt, W., Richter, S., Eisenhofer, G., Ruiz-Babot, G., Guasti, L., & Walch, A. K. (2019) · Histochemistry and Cell Biology · doi:10.1007/s00418-019-01772-w · Cited by 14
Self-citationLee, C., O’Day, P., Stouffer, D. G., Auchus, R. J., & Turcu, A. F. (2025) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2025.106717 · Cited by 17
Diagnosis of hypogonadism in ageing men
Kaufman, J. (2022) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-022-09763-4 · Cited by 20
Cazares, L. H., Ward, M. D., Brueggemann, E. E., Kenny, T., Demond, P. S., Mahone, C. R., Martins, K. A. O., Nuss, J. E., Glaros, T., & Bavari, S. (2016) · Clinical Proteomics · doi:10.1186/s12014-016-9119-8 · Cited by 14
“This study also highlights the superiority of mass spectrometry methods such as SRM and LC-HRMS for protein quantitation and characterization over western blotting and other immuno-affinity methods, which has been the topic of discussion in recent review articles [34, 35].”
Determination of neurosteroids in human cerebrospinal fluid in the 21st century: A review
Teubel, J., & Parr, M. K. (2020) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2020.105753 · Cited by 14
Aydin, E., Drotleff, B., Noack, H., Derntl, B., & Lämmerhofer, M. (2021) · Journal of Chromatography B · doi:10.1016/j.jchromb.2021.122939 · Cited by 15
Antonelli, G., Sciacovelli, L., Aita, A., Padoan, A., & Plebani, M. (2018) · Clinica Chimica Acta · doi:10.1016/j.cca.2018.07.005 · Cited by 15
Shi, Z., Hamdard, E., Lv, Z., Dai, H., Wei, Q., Shen, L., Karwand, B., & Shi, F. (2019) · Animals · doi:10.3390/ani9110977 · Cited by 14
Huayllas, M. K. P., Smith, L. M., Gallagher, J. C., Netzel, B. C., Singh, R. J., & Kater, C. E. (2021) · Clinical Endocrinology · doi:10.1111/cen.14445 · Cited by 14
Boyle, P. C., Andralojc, K. M., van der Velden, S., Najmabadi, S., de Groot, T., Turczynski, C., & Stanford, J. B. (2024) · Frontiers in Reproductive Health · doi:10.3389/frph.2023.1321284 · Cited by 18
Hamidovic, A., Mumford, S. L., Schisterman, E. F., Davis, J. M., & Soumare, F. (2024) · Molecular Psychiatry · doi:10.1038/s41380-024-02566-w · Cited by 16
“Indeed, the gold standard mass spectrometry distinguishes compounds with similar structures, such as hormones from the steroid hormone biosynthesis pathway, better than the immunoassay technology [10], which has been commonly implemented in the previous research on steroid hormone levels in PMDD.”
Gonadal steroid levels in rock pigeon eggs do not represent adequately maternal allocation
Kumar, N., van Faassen, M. H. J. R., de Vries, B., Kema, I., Gahr, M. L., & Groothuis, T. G. G. (2018) · Scientific Reports · doi:10.1038/s41598-018-29478-4 · Cited by 13
Mass Spectrometry-Based Steroid Profiling: Meeting Unmet Clinical Needs
Choi, M. H. (2021) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.253.171 · Cited by 14
“…for steroids of similar chemical structure and standardization across assays for accurate quantification of individual steroid hormones limits their applicability in precision or personalized medicine (Lee et al. 2006; Hsing et al. 2007; Middle 2007; Wood et al. 2008; Taylor et al. 2015).”
BackgroundAssociation of primary allostatic load mediators and metabolic syndrome (MetS): A systematic review
Osei, F., Block, A., & Wippert, P. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.946740 · Cited by 15
“Mass spectrometry provides reliable cortisol measurement outcomes and prevents cross-reactivity of metabolites (74, 82, 84).”
BackgroundGjorgoska, M., & Rižner, T. L. (2024) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2024.106578 · Cited by 16
Kosicka, K., Siemiątkowska, A., Szpera-Goździewicz, A., Krzyścin, M., Bręborowicz, G. H., & Główka, F. K. (2018) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563218783789 · Cited by 13
“The result is the ability to determine multiple substances in one analytical run.(1) Chromatographic methods have been widely used in the analysis of steroids for many years.”
Adrenal steroids reference ranges in infancy determined by LC-MS/MS
Enver, E. O., Vatansever, P., Guran, O., Bilgin, L., Boran, P., Turan, S., Haklar, G., Bereket, A., & Guran, T. (2022) · Pediatric Research · doi:10.1038/s41390-021-01739-5 · Cited by 12
Mažeikienė, A., Bekešienė, S., Karčiauskaitė, D., Mazgelytė, E., Larsson, G., Petrėnas, T., Kaminskas, A., Songailienė, J., Utkus, A., Vaičaitienė, R., et al. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182212239 · Cited by 14
Pesonen, E. J., Pussinen, P. J., & Huhtaniemi, I. T. (2016) · European Journal of Endocrinology · doi:10.1530/eje-15-0757 · Cited by 12
Self-citationAlbert, L., Profitós, J., Sánchez‐Delgado, J., Capel, I., González-Clemente, J. M., Subías, D., Cano, A., Berlanga, E., Espinal, A., Hurtado, M., et al. (2019) · International Journal of Endocrinology · doi:10.1155/2019/7251010 · Cited by 12
A comparison of salivary steroid levels during diagnostic tests for adrenal insufficiency
Dušková, M., Šimůnková, K., Vítků, J., Sosvorová, L., Jandíková, H., Pospíšilová, H., Šrámková, M., Kosák, M., Kršek, M., Hána, V., et al. (2016) · Prague Medical Report · doi:10.14712/23362936.2016.2 · Cited by 11
“Despite this, the availability and costeffectiveness of immunoassay methods remain the method of choice for routine clinical settings (Taylor et al., 2015).”
MethodMartínez-Escribano, A., Maroto-García, J., Ruiz-Galdón, M., Barrios-Rodríguez, R., Álvarez-Millán, J. J., Cabezas-Sánchez, P., Plaza-Andrades, I., Molina-Vega, M., Tinahones, F. J., Queipo-Ortuño, M. I., et al. (2020) · Biomolecules · doi:10.3390/biom10121697 · Cited by 11
“This can be due to the different assays used, but also due to the characteristics of the study population [21].”
MethodJolicoeur, V., Houde, M., Loseto, L. L., Michaud, R., & Verreault, J. (2024) · Environment International · doi:10.1016/j.envint.2024.108647 · Cited by 13
Su, M., Drotleff, B., Janker, T., Bürger, Z., Kimmig, A.-C. S., Derntl, B., & Lämmerhofer, M. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c01912 · Cited by 15
Vega‐Beyhart, A., Laguna, J., Díaz-Catalán, D., Boswell, L., Mora, M., Halperín, I., Casals, G., & Hanzu, F. A. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.833644 · Cited by 14
Neurosteroids and early-life programming: An updated perspective
Sze, Y., & Brunton, P. J. (2022) · Current Opinion in Endocrine and Metabolic Research · doi:10.1016/j.coemr.2022.100367 · Cited by 19
Applying mass spectrometric methods to study androgen biosynthesis and metabolism in prostate cancer
Knuuttila, M., Hämäläinen, E. K., & POUTANEN, M. H. (2019) · Journal of Molecular Endocrinology · doi:10.1530/jme-18-0150 · Cited by 11
Ong, M. L. Y., Green, C. G., Rowland, S. N., & Heaney, L. M. (2023) · Analytical Science Advances · doi:10.1002/ansa.202300003 · Cited by 9
Blunted Cortisol Response to Acute Psychosocial Stress in Women With Premenstrual Dysphoric Disorder
Hamidovic, A., Davis, J. M., & Soumare, F. (2024) · The International Journal of Neuropsychopharmacology · doi:10.1093/ijnp/pyae015 · Cited by 15
Gazárková, T., Vlčková, H., Plachká, K., Vagnerová, K., Dubecová, D., Klusoňová, P., Pácha, J., Švec, F., & Nováková, L. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.343362 · Cited by 11
Eendebak, R. J. A. H., Huhtaniemi, I. T., Pye, S. R., Ahern, T., O’Neill, T. W., Bártfai, G., Casanueva, F. F., Maggi, M., Forti, G., Alston, R. D., et al. (2016) · European Journal of Endocrinology · doi:10.1530/eje-16-0447 · Cited by 10
Self-citationBoddu, S. K., & Madhavan, S. (2017) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2017-0166 · Cited by 10
Improving LC-MS/MS measurements of steroids with differential mobility spectrometry
Chai, Y., Grebe, S. K. G., & Maus, A. D. (2023) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2023.10.001 · Cited by 11
“Today, liquid chromatography-tandem mass spectrometry (LC-MS/MS) is widely recognized as the preferred platform for steroid measurement due to its superior analytical specificity and sensitivity [3,5].”
BackgroundThe effects of age and obesity on postprandial dynamics of serum testosterone levels in men
de Velde, F. V., Reyns, T., Toye, K. R. C., Fiers, T., Kaufman, J., T'Sjoen, G. G., & Lapauw, B. (2019) · Clinical Endocrinology · doi:10.1111/cen.14141 · Cited by 11
Biomarkers of male hypogonadism in childhood and adolescence
Rey, R. A. (2020) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2020-0024 · Cited by 10
Androgens by immunoassay and mass spectrometry in children with 46,XY disorder of sex development
de Oliveira, L. R., Longui, C. A., Guaragna‐Filho, G., Costa, J. L., Lanaro, R., Silva, D. A., Chiamolera, M. I., de Mello, M. P., Morcillo, A. M., Maciel‐Guerra, A. T., et al. (2020) · Endocrine Connections · doi:10.1530/ec-20-0454 · Cited by 10
van Helden, J., & Weiskirchen, R. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.09.009 · Cited by 10
Bäcklund, N., Brattsand, G., Lundstedt, S., Aardal, E., Bartuseviciene, I., Berinder, K., Höybye, C., Burman, P., Edén Engström, B., Isaksson, A., et al. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0141 · Cited by 9
Analysis of Pharmacokinetics in the Cochlea of the Inner Ear
Sawamura, S., Ogata, G., Asai, K., Razvina, O., Ōta, T., Zhang, Q., Madhurantakam, S., Akiyama, K., Ino, D., Kanzaki, S., et al. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.633505 · Cited by 12
“In general, the advantages are relatively high quantitativity, easy handling, and time- and cost savings (Stead, 2000; Taylor et al., 2015).”
BackgroundNeal, S. P., Hodges, W. N., Velosa, D. C., Aderorho, R., Lucas, S. W., & Chouinard, C. D. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-04953-8 · Cited by 11
Cortisol in metabolic syndrome
Mazgelytė, E., & Karčiauskaitė, D. (2024) · Advances in clinical chemistry · doi:10.1016/bs.acc.2024.06.008 · Cited by 24
Disorders of Sex Development in Office Practice
Priyadarshini, S., & Sharma, R. (2023) · The Indian Journal of Pediatrics · doi:10.1007/s12098-023-04640-7 · Cited by 9
“Liquid Chromatography Mass Spectroscopy (LCMS/MS) requires smaller sample volumes, can analyze multiple steroid metabolites from the same blood specimen and is considered the gold standard method to measure steroid metabolites [13].”
BackgroundWu, D., Ye, L., Zhang, X., Yin, M., Guo, Y., & Zhou, J. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1164679 · Cited by 12
Certified testosterone immunoassays for hyperandrogenaemia
Luque‐Ramírez, M., Mendiguchía, L. J., Cano, A. M. G., Fernández‐Durán, E., Rosa, V. D. D., Nattero‐Chávez, L., Ortiz-Flores, A. E., & Escobar-Morreale, H. F. (2018) · European Journal of Clinical Investigation · doi:10.1111/eci.13029 · Cited by 10
“Some T immunoassays pitfalls are derived from calibration and validation issues.(6) On February 2010, a consensus statement endorsed by a group of scientific societies, regulatory agencies and industry representatives stated a panel of recommendations to standardize T assays.”
BackgroundDiscordance between testosterone measurement methods in castrated prostate cancer patients
Rouleau, M., Lemire, F., Déry, M., Thériault, B., Dubois, G., Fradet, Y., Toren, P., Guillemette, C., Lacombe, L., Klotz, L. H., et al. (2019) · Endocrine Connections · doi:10.1530/ec-18-0476 · Cited by 9
Stephenson, A., Hunter, B., Shaw, P. N., Kassim, N. S. A., Trengove, R. D., Takechi, R., Lam, V., & Mamo, J. C. L. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-04527-8 · Cited by 9
“Immunoassays also require a significantly larger amount of sample in comparison to HPLC or LC-MS/MS, which often may not be suitable for small animal model studies, where sample volume is limited [15].”
BackgroundChanges in prenatal testosterone and sexual desire in expectant couples
Sim, L., Chopik, W. J., Wardecker, B. M., & Edelstein, R. S. (2020) · Hormones and Behavior · doi:10.1016/j.yhbeh.2020.104823 · Cited by 10
“Immunoassays are commonly used because of their cost effectiveness, accessibility, and ease of use (Taylor et al., 2015); however, they have been criticized for issues such as cross-reactivity (e.”
BackgroundSait, S. T. L., Survilienė, V., Jüssi, M., González, S. V., Ciesielski, T. M., Jenssen, B. M., & Asimakopoulos, A. G. (2022) · Talanta · doi:10.1016/j.talanta.2022.124109 · Cited by 9
Roli, L., Santi, D., Belli, S., Tagliavini, S., Cavalieri, S., Santis, M. C. D., Baraldi, E., Fanelli, F., Mezzullo, M., Granata, A. R. M., et al. (2017) · Journal of Endocrinological Investigation · doi:10.1007/s40618-017-0653-7 · Cited by 9
Krebs, A., Dickhuth, K., Mumm, R., Stier, B., Doerfer, J., Grueninger, D., Wurm, M., Brichta, C., & Schwab, K. O. (2019) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2018-0451 · Cited by 8
van Faassen, M. H. J. R., van der Veen, A., van Ockenburg, S. L., de Jong, H., de Vries, E. G. E., & Kema, I. P. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-0455 · Cited by 8
“Although immunoassays are easy to use and provide valuable information, LC–MS/MS is the preferred method for analyzing small molecules [18, 31].”
MethodOwens, S. J., Weickert, T. W., Purves-Tyson, T. D., Ji, E., White, C., Galletly, C. A., Liu, D., O׳Donnell, M., & Weickert, C. S. (2018) · Complex Psychiatry · doi:10.1159/000495062 · Cited by 10
Yi, X., Huang, X., Xiong, Y., & Wu, Y. (2025) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.4c00338 · Cited by 7
Reliable in-house LC-MS/MS method for steroid hormone analysis: Validations and comparisons
He, Y., Luo, M., Hu, J., Li, Q., Yang, S., Zhen, Q., & Ma, L. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120610 · Cited by 8
Casto, K. V., Arthur, L. C., Lynch-Wells, S., & Blake, K. R. (2023) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2023.106367 · Cited by 8
“liquid chromatography–tandem mass spectrometry and serum blood samples, while balancing practicality and cost (Taylor et al., 2015).”
Mu, D., Xia, Q., Ma, Y., Wang, X., Gao, Y., Ma, X., Xie, S., Hou, L., Zhang, Q., Zhao, F., et al. (2024) · Endocrine Practice · doi:10.1016/j.eprac.2024.04.008 · Cited by 9
Snaterse, G., van Dessel, L. F., TAYLOR, A. E. R., Visser, J. A., Arlt, W., Lolkema, M. P., & Hofland, J. (2021) · Steroids · doi:10.1016/j.steroids.2021.108800 · Cited by 10
“Liquid chromatography–tandem mass spectrometry (LC–MS/MS) combines multi-steroid profiling capabilities with superior sensitivity and specificity [14,15] over older techniques [16,17], while maintaining high sample throughput [18,19].”
Self-citationLapić, I., Oguić, S. K., & Rogić, D. (2021) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2021.1908590 · Cited by 7
“These discrepancies once again depict the differences between antibodies and assay formulations among manufacturers [6] and discourage their interchangeable use.”
BackgroundSoares, D. R. D., Antunes, M. V., & Linden, R. (2021) · Bioanalysis · doi:10.4155/bio-2021-0101 · Cited by 7
Ganie, M. A., Chowdhury, S., Suri, V., Joshi, B. N., Bhattacharya, P. K., Agrawal, S., Malhotra, N., Sahay, R. K., Jabbar, P. K., Nair, A., et al. (2023) · The Lancet Regional Health - Southeast Asia · doi:10.1016/j.lansea.2023.100226 · Cited by 9
Uninterrupted real‐time cerebral stress level monitoring using wearable biosensors: A review
Mishra, A., Agrawal, M., Ali, A., & Garg, P. (2023) · Biotechnology and Applied Biochemistry · doi:10.1002/bab.2491 · Cited by 11
“8,9 A questionnaire for self-reporting and a specific biomarker analysis, the two methods, based on blood and urine tests is presently used to measure an individual’s level of stress.”
MethodAre serum cortisol measurements by immunoassays reliable?
Haq, N., Araque, K., Kanegusuku, A. G., Wei, B., & Soldin, S. J. (2020) · Medical Research Archives · doi:10.18103/mra.v8i5.2128 · Cited by 9
Rochira, V., & Carani, C. (2017) · Endocrinology · doi:10.1007/978-3-319-44441-3_27 · Cited by 11
Wang, Q., & Mesaros, C. (2024) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2024.106618 · Cited by 8
Gent, R., Barbier, I. D., Atkin, S. L., Newell‐Fugate, A. E., & Swart, A. C. (2022) · Journal of Chromatography B · doi:10.1016/j.jchromb.2022.123576 · Cited by 7
Mid-Luteal Progesterone Is Inversely Associated with Premenstrual Food Cravings
Hamidovic, A., Soumare, F., Naveed, A., & Davis, J. M. (2023) · Nutrients · doi:10.3390/nu15051097 · Cited by 7
Braun, V., Ceglarek, U., Gaudl, A., Gawinecka, J., Müller, D., Rauh, M., Weber, M., & Seger, C. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0847 · Cited by 8
“Over the past two decades, the possibilities and limitations of this technology have become well understood [1 – 3].”
Shim, J., Ahn, C. H., Park, S. S., Noh, J., Lee, C., Lee, S., Kim, J. H., & Choi, M. H. (2023) · Journal of the Endocrine Society · doi:10.1210/jendso/bvad155 · Cited by 6
Yi, X., Li, X., Luo, H., Lin, G., Zhou, J., Xiong, Y., & Wu, Y. (2024) · Talanta · doi:10.1016/j.talanta.2024.127041 · Cited by 6
Dahl, S. R., Bakke, L. H., Thorsby, P. M., & Zykova, S. N. (2024) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2024.2437620 · Cited by 6
Good vibrations: An observational study of real-life stress induced by a stage performance
Everaerd, D., Henckens, M. J. A. G., Bloemendaal, M., Bovy, L., Kaldewaij, R., Maas, F. M. W. M., Mulders, P. C. R., Niermann, H. C. M., van de Pavert, I., Przeździk, I., et al. (2020) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2020.104593 · Cited by 8
Dušková, M., Kolátorová, L., Vítků, J., Jandíková, H., Rácz, B., Chlupáčová, T., Cordeiro, J. D., & Stárka, L. (2015) · Prague Medical Report · doi:10.14712/23362936.2015.66 · Cited by 6
“Therefore, with proper standardisation and awareness of the method’s limitations, RIA remains the first choice for routine analyses (Taylor et al., 2015).”
BackgroundBusby, E. R., & Sherwood, N. M. (2017) · PLoS ONE · doi:10.1371/journal.pone.0174452 · Cited by 7
Mass spectrometry-based metabolic signatures of sex steroids in breast cancer
Choi, M. H. (2017) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2017.09.023 · Cited by 6
“Although they are very useful as a screening method in clinical practice, drawbacks of immunoassays, such as cross reactivity caused by structural similarity and conjugation diversity of steroid backbone, have been well described (Taylor et al., 2015).”
BackgroundUtility of a commercially available blood steroid profile in endocrine practice
Sarathi, V., Atluri, S., Pradeep, T. S., Rallapalli, S., Rakesh, C. V., Tirupati, S., & Kumar, K. (2019) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/ijem.ijem_531_18 · Cited by 7
Gargus, E. S., Bae, Y., Chen, J., Moss, K. J., Ingram, A., Zhang, J., Montgomery, N. T., Boots, C. E., Funk, W. E., & Woodruff, T. K. (2022) · Biomedicines · doi:10.3390/biomedicines10071646 · Cited by 6
“While immunoassays are widely used in reproductive biology, they suffer from inherent issues of sensitivity and specificity because steroid hormones are poor antigens and exhibit cross-reactivity between similar analytes [14,15], and due to complex culture media compositions, which can interfere with the assay [15–19].”
BackgroundSample multiplexing for increasing throughput for quantification of estrogens in serum by LC–MS/MS
Yuan, T. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-022-04423-7 · Cited by 9
“To improve the analytical limitations, liquid chromatography-tandem mass spectrometry (LC–MS/MS) has been introduced for the quantification of estrogens, and it can provide powerful analytical abilities with high specificity and sensitivity [10, 11].”
Comas, I., Ferrer, R., Planas, J., Celma, A., Regis, L., & Moróte, J. (2017) · Actas Urológicas Españolas · doi:10.1016/j.acuro.2017.01.007 · Cited by 6
Girel, S., Markin, P. A., Tobolkina, E., Boccard, J., Moskaleva, N. E., Rudaz, S. L., & Appolonova, S. A. (2024) · Scientific Reports · doi:10.1038/s41598-024-51859-1 · Cited by 6
Clegg, S. R., & Millson, S. H. (2021) · Comparative Cognition & Behavior Reviews · doi:10.3819/ccbr.2021.160002 · Cited by 6
“In addition, concentrations can vary with hair colour, as seen in dogs and chimpanzees (Bennett & Hayssen, 2010; Taylor et al., 2015; Wennig, 2000; Yamanashi et al., 2013).”
BackgroundModelling timing and tempo of adrenarche in a prospective cohort study
Dashti, S. G., Mundy, L. K., Goddings, A., Canterford, L. D., Viner, R., Carlin, J. B., Patton, G. C., & Moreno‐Betancur, M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0278948 · Cited by 5
Hamidovic, A., Davis, J. M., Soumare, F., Datta, A., & Naveed, A. (2023) · Biomolecules · doi:10.3390/biom13040652 · Cited by 5
Steroid profiling in adrenal disease
Mu, D., Sun, D., Qian, X., Ma, X., Qiu, L., Cheng, X., & Yu, S. (2023) · Clinica Chimica Acta · doi:10.1016/j.cca.2023.117749 · Cited by 6
Sebihi, S., Monperrus, M., Coste, P., Huchet, E., Lingrand, M., Glise, S., Bouchard, C., Ortiz‐Zarragoitia, M., & Bolliet, V. (2024) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2024.106627 · Cited by 5
Systemic detectability of dexamethasone and prednisolone after eye drop application in horses
Stucki, M., Voegel, C. D., Binz, T. M., Kræmer, T., Lavaud, A., & Voelter, K. (2021) · Equine Veterinary Journal · doi:10.1111/evj.13418 · Cited by 5
Metadata
- Authors
- Taylor, A. E., Keevil, B., & Huhtaniemi, I. T.
- Affiliations
- University of Turku (FI)
- Corresponding author
- Keevil, Brian
- Huhtaniemi, Ilpo T
- Venue
- European Journal of Endocrinology
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-08
- Volume
- 173
- Issue
- 2
- Pages
- D1-D12
- ISSN
- 0804-4643 (ISSN-L)
- 1479-683X
- OpenAlex
- W2110473840
- Cited by
- 320
- References
- 74
- Citations by year
- 2026: 20 · 2025: 23 · 2024: 31 · 2023: 42 · 2022: 35 · 2021: 33 · 2020: 27 · 2019: 33 · 2018: 32 · 2017: 26 · 2016: 15 · 2015: 3
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Journal of Endocrinology (publishedVersion)
- PubMed (publishedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- steroid hormones, mass spectrometry, immunoassay, steroid hormone measurement, method comparison
- MeSH terms
- Animals, Chromatography, Liquid, Hormones, Humans, Immunoassay, Mass Spectrometry, Steroids, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.