Deep learning to diagnose pouch of Douglas obliteration with ultrasound sliding sign
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Objectives: Pouch of Douglas (POD) obliteration is a severe consequence of inflammation in the pelvis, often seen in patients with endometriosis. The sliding sign is a dynamic transvaginal ultrasound (TVS) test that can diagnose POD obliteration. We aimed to develop a deep learning (DL) model to automatically classify the state of the POD using recorded videos depicting the sliding sign test. Methods: Two expert sonologists performed, interpreted, and recorded videos of consecutive patients from September 2018 to April 2020. The sliding sign was classified as positive (i.e. normal) or negative (i.e. abnormal; POD obliteration). A DL model based on a temporal residual network was prospectively trained with a dataset of TVS videos. The model was tested on an independent test set and its diagnostic accuracy including area under the receiver operating characteristic curve (AUC), accuracy, sensitivity, specificity, and positive and negative predictive value (PPV/NPV) was compared to the reference standard sonologist classification (positive or negative sliding sign). Results: In a dataset consisting of 749 videos, a positive sliding sign was depicted in 646 (86.2%) videos, whereas 103 (13.8%) videos depicted a negative sliding sign. The dataset was split into training (414 videos), validation (139), and testing (196) maintaining similar positive/negative proportions. When applied to the test dataset using a threshold of 0.9, the model achieved: AUC 96.5% (95% CI: 90.8–100.0%), an accuracy of 88.8% (95% CI: 83.5–92.8%), sensitivity of 88.6% (95% CI: 83.0–92.9%), specificity of 90.0% (95% CI: 68.3–98.8%), a PPV of 98.7% (95% CI: 95.4–99.7%), and an NPV of 47.7% (95% CI: 36.8–58.2%). Conclusions: We have developed an accurate DL model for the prediction of the TVS-based sliding sign classification. Lay summary: Endometriosis is a disease that affects females. It can cause very severe scarring inside the body, especially in the pelvis − called the pouch of Douglas (POD). An ultrasound test called the 'sliding sign' can diagnose POD scarring. In our study, we provided input to a computer on how to interpret the sliding sign and determine whether there was POD scarring or not. This is a type of artificial intelligence called deep learning (DL). For this purpose, two expert ultrasound specialists recorded 749 videos of the sliding sign. Most of them (646) were normal and 103 showed POD scarring. In order for the computer to interpret, both normal and abnormal videos were required. After providing the necessary inputs to the computer, the DL model was very accurate (almost nine out of every ten videos was correctly determined by the DL model). In conclusion, we have developed an artificial intelligence that can interpret ultrasound videos of the sliding sign that show POD scarring that is almost as accurate as the ultrasound specialists. We believe this could help increase the knowledge on POD scarring in people with endometriosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Maicas et al. developed a highly accurate AI model for the classification of the pouch of Douglas obliteration as a cause of pelvic inflammation often seen in endometriosis via detection of the so-called ‘sliding sign’ [216].”
From Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology (2023) · cites this paper as [216]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In total, 11 articles were summarized in this section, including the topics of endometriosis [216,217], premature ovarian failure [218,219], uterine fibroids [220,221], follicle tracking [222,223], and ectopic pregnancies [224,225].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yaşlı Kadınlarda Üreme Sağlığı
Kokanalı, D., & Engin Üstün, Y. (n.d.) · DergiPark (Istanbul University) · Cited by 170,090
Yaşlı Kadınlarda Üreme Sağlığı
Kokanalı, D., & Üstün, Y. E. (2019) · Jinekoloji-Obstetrik ve Neonatoloji Tıp Dergisi · Cited by 169,629
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
PyTorch: An Imperative Style, High-Performance Deep Learning Library
Paszke, A., Gross, S., Massa, F., Lerer, A., Bradbury, J., Chanan, G., Killeen, T., Lin, Z., Gimelshein, N., Antiga, L., et al. (2019) · arXiv · doi:10.48550/arxiv.1912.01703 · Cited by 31,473
A Closer Look at Spatiotemporal Convolutions for Action Recognition
Tran, D., Wang, H., Torresani, L., Ray, J., LeCun, Y., & Paluri, M. (2017) · arXiv · doi:10.48550/arxiv.1711.11248 · Cited by 3,664 · cited 2×
“We chose the state-of-the-art model Resnet (2+1)D (Tran et al. 2018) that showed superior performance by splitting the spatiotemporal components of the video.”
BackgroundMethodA Closer Look at Spatiotemporal Convolutions for Action Recognition
Tran, D., Wang, H., Torresani, L., Ray, J., LeCun, Y., & Paluri, M. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00675 · Cited by 3,516
STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.246280 · Cited by 984
Guerriero, S., Condous, G., van den Bosch, T., Valentin, L., Leone, F. P. G., Van Schoubroeck, D., Exacoustos, C., Installé, A. J. F., Martins, W. P., Abrao, M. S., et al. (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15955 · Cited by 900 · cited 1×
“Even in the context of endometriosis, most gynecologists are not seeing POD obliteration evaluated on TVS from their local radiology practices (Leonardi et al. 2020 c ) despite the recommendations by the International Deep Endometriosis Analysis (IDEA) group (Guerriero et al. 2016).”
BackgroundSelf-citationImaging modalities for the non-invasive diagnosis of endometriosis
Nisenblat, V., Bossuyt, P. M., Farquhar, C., Johnson, N., & Hull, M. L. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009591.pub2 · Cited by 538 · cited 2×
“Ultrasound has undoubtedly become indispensable in the diagnostic workup of gynecologic pathology, including endometriosis (Nisenblat et al. 2016), but several flaws with this imaging modality exist.”
Self-citationDiagnostic delay for endometriosis in Austria and Germany: causes and possible consequences
Hudelist, G., Fritzer, N., Thomas, A., Niehues, C., Oppelt, P., Haas, D., Tammaa, A., & Salzer, H. (2012) · Human Reproduction · doi:10.1093/humrep/des316 · Cited by 483 · cited 1×
“Specific to endometriosis, the development of this DL model may advance our ability to diagnose women non-invasively, yielding benefits such as a reduction in the delay to diagnosis (Hudelist et al. 2012), acknowledgment of symptoms, and optimizing access to care (As-Sanie et al. 2019).”
Background
Research works printed but not linked: 3
- [1]1. Altman D, Machin D, Bryant T & Gardner M 2013 Statistics with Confidence: Confidence Intervals and Statistical Guidelines, 2nd ed. BMJ Books, Wiley London, UK
- [18]18. Melnyk A, Rindos NB, Khoudary SR El & Lee TTM 2020 Comparison of laparoscopic hysterectomy in patients with endometriosis with and without an obliterated cul-de-sac. Journal of Minimally Invasive Gynecology 27 892-900. (https://doi.org/10.1016/j. jmig.2019.07.001) · doi:10.1016/j
- [26]26. Tompsett J, Leonardi M, Gerges B, Lu C, Reid S, Espada M & Condous G 2019 Ultrasound-based endometriosis staging system: validation study to predict complexity of laparoscopic surgery. Journal of Minimally Invasive Gynecology 26 477-483. (https://doi.org/10.1016/j. jmig.2018.05.022) · doi:10.1016/j
Cited by
Pascoal, E., Wessels, J. M., Aas‐Eng, M. K., Abrao, M. S., Condous, G., Jurkovic, D., Espada, M., Exacoustos, C., Ferrero, S., Guerriero, S., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.24892 · Cited by 188
Self-citationBreastScreening-AI: Evaluating medical intelligent agents for human-AI interactions
Calisto, F. M., Santiago, C., Nunes, N., & Nascimento, J. C. (2022) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2022.102285 · Cited by 125
Clinical use of artificial intelligence in endometriosis: a scoping review
Sivajohan, B., Elgendi, M., Menon, C., Allaire, C., Yong, P. J., & Bedaiwy, M. A. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00638-1 · Cited by 124
“…studies in this category was relatively consistent compared to other categories with similar SE and SP. Diagnostic or predictive models for endometriosis using imaging Only three studies 59 – 61 explored the use of imaging variables as their primary inputs for their AI models as seen in Table 7.”
BackgroundMethodResultInfluentialAvery, J., Deslandes, A., Freger, S., Leonardi, M., Lo, G., Carneiro, G., Condous, G. S., Hull, M. L., Hull, M. L., Carneiro, G., et al. (2023) · Fertility and Sterility · doi:10.1016/j.fertnstert.2023.12.008 · Cited by 109
Self-citationAssessing the Utility of artificial intelligence in endometriosis: Promises and pitfalls
Dungate, B., Tucker, D. R., Goodwin, E., & Yong, P. J. (2024) · Women s Health · doi:10.1177/17455057241248121 · Cited by 57
“19 Another benefit of transfer learning is the ability to use knowledge translation across imaging modalities.”
BackgroundMoro, F., Giudice, M. T., Ciancia, M., Zaçe, D., Baldassari, G., Vagni, M., Tran, H. E., Scambia, G., & Testa, A. C. (2025) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.29171 · Cited by 55
“One study developed a DL model, using ultrasound videoclips as the model input, to detect indirect signs of pelvic endometriosis (i.e. sliding sign), with an AUC of 0.96 51 .”
InfluentialJost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216833 · Cited by 44
“In total, 11 articles were summarized in this section, including the topics of endometriosis [216,217], premature ovarian failure [218,219], uterine fibroids [220,221], follicle tracking [222,223], and ectopic pregnancies [224,225].”
BackgroundMethodInfluentialBrandão, M., Mendes, F., Martins, M., Cardoso, P., Macedo, G., Mascarenhas, T., & Mascarenhas, M. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13041061 · Cited by 49
“In 2021, a DL model was created based on a temporal residual network for automatic classification of the sliding sign as positive (normal) or negative (abnormal, indicating POD obliteration) using a dataset of 749 recorded ultrasound videos [67].”
MethodArtificial intelligence in abdominal and pelvic ultrasound imaging: current applications
Cai, L., & Pfob, A. (2024) · Abdominal Radiology · doi:10.1007/s00261-024-04640-x · Cited by 22
“Gao [37].”
Artificial intelligence applications in endometriosis imaging
Mittal, S., Tong, A. Y., Young, S. W., & Jha, P. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-04897-w · Cited by 24
“Maicas et al. [ 23 ] (2021) cre - ated a DL model to assess POD obliteration in 414 TVUS cines depicting the sliding sign test.”
Cetera, G. E., Tozzi, A. E., Chiappa, V., Castiglioni, I., Merli, C. E. M., & Vercellini, P. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13102950 · Cited by 20
“The accuracy, sensitivity and specificity of such a model were all just short of 90%, indicating high diagnostic performance [64].”
Meaningful Transparency for Clinicians: Operationalising HCXAI Research with Gynaecologists
Schor, B. G. S., Kallina, E., Singh, J., & Blackwell, A. F. (2024) · ACM Conference on Fairness, Accountability, and Transparency (FAccT) · doi:10.1145/3630106.3658971 · Cited by 20
“We now ground this investigation in a specific clinical domain: gynaecological imagery.”
BackgroundZhang, Y., Wang, H., Butler, D., To, M., Avery, J., Hull, M. L., & Carneiro, G. (2023) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi53787.2023.10230667 · Cited by 29
“For the TVUS pre-training, we adopted the ResNet (2+1)D model proposed in [10].”
MethodInfluentialSelf-citationMoassefi, M., Faghani, S., Çolak, C., Sheedy, S. P., Andrieu, P. C., Wang, S. S., McPhedran, R. L., Flicek, K. T., Suman, G., Takahashi, H., et al. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-04942-8 · Cited by 13
“[44].”
Are sonographers the future ‘gold standard’ in the diagnosis of endometriosis?
Deslandes, A., Panuccio, C., Avery, J., Condous, G. S., Leonardi, M., Knox, S., Chen, H., & Hull, M. L. (2024) · Sonography · doi:10.1002/sono.12402 · Cited by 13
“Maicas & Leonardi et al. 67 reported high diagnostic accuracy when using a deep learning technique (Resnet(2 + 1)D) to detect POD obliteration from videos of the sonographic ‘ sliding sign ’ .”
Self-citationA novel machine learning-based proposal for early prediction of endometriosis disease
Enamorado-Díaz, E., Morales-Trujillo, L., García-García, J. A., Marcos, A. T., Navarro-Pando, J. M., & Escalona-Cuaresma, M.-J. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.126621 · Cited by 11
Artificial Intelligence and Gynecologic Surgery
Pipes, G. M., Hung, A. J., & Kim, K. H. (2025) · Obstetrics and Gynecology · doi:10.1097/aog.0000000000006052 · Cited by 13
Artificial Intelligence in Endometriosis Imaging: A Scoping Review
AlSaad, R., Farrell, T. J., Elhenidy, A. M., Albasha, S. E. M. E., & Thomas, R. M. (2026) · AI · doi:10.3390/ai7020043 · Cited by 7
“…detection, and segmentation: Spatial modeling (detection/ segmentation) was also a common target [25,29–32, 39, 40 Staging and adhesion assessment: A smaller set of studies addressed staging and re-lated constructs [21,36,49,50], including POD obliteration/sliding sign modeling [21,36,49,50].”
Recent advancements of artificial intelligence in minimally invasive surgery for endometriosis
Zhao, T., Liu, Y., Wei, Z., & Yi, X. (2025) · Intelligent Surgery · doi:10.1016/j.isurg.2025.10.001 · Cited by 6
The Effectiveness of Self-supervised Pre-training for Multi-modal Endometriosis Classification*†
Butler, D., Wang, H., Zhang, Y., To, M., Condous, G. S., Leonardi, M., Knox, S., Avery, J., Hull, M. L., & Carneiro, G. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340504 · Cited by 12
“Related work has been done on detecting endometrial cancer from 2D images [26], while Maicas et al. [27] use temporal residual networks to detect pouch-of-Douglas (POD) obliteration.”
BackgroundSelf-citationUnpaired multi-modal training and single-modal testing for detecting signs of endometriosis
Zhang, Y., Wang, H., Butler, D., Smart, B., Xie, Y., To, M., Knox, S., Condous, G. S., Leonardi, M., Avery, J., et al. (2025) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2025.102575 · Cited by 7
Self-citationPetashvili, D., Wang, H., Deslandes, A., Avery, J., Condous, G. S., Carneiro, G., Hull, M. L., & Chen, H. (2024) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi56570.2024.10635761 · Cited by 4
“There are also multiple works [9, 10, 11, 12, 13, 14] explore the area of Endometriosis diagnosis, however, not in the TVUS multi-annotator scenario.”
BackgroundSelf-citationSidhu, A., Dahiya, N., Eathorne, A., Armour, M., Barto, W., & Condous, G. S. (2024) · Turkish Journal of Colorectal Disease · doi:10.4274/tjcd.galenos.2024.2023-12-1 · Cited by 5
Self-citationCutting-edge care: unleashing artificial intelligence's potential in gynecologic surgery
Leaf, M.-C., Musselman, K., & Wang, K. C. (2024) · Current Opinion in Obstetrics & Gynecology · doi:10.1097/gco.0000000000000971 · Cited by 2
The Role of Ultrasound in the Evolving Landscape of Precision Imaging of Endometriosis
Shetty, R., Aharoni, S., & Leonardi, M. (2025) · Current Obstetrics and Gynecology Reports · doi:10.1007/s13669-025-00424-2 · Cited by 2
“11) [60].”
Self-citationArtificial Intelligence in Gynecologic Imaging
Briggs, M., Saif, A., Kline, T. L., VanBuren, W. M., Rassier, S. L. C., & Green, I. C. (2026) · Clinical Obstetrics & Gynecology · doi:10.1097/grf.0000000000000984 · Cited by 2
Balıkoğlu, M., Tanyeri, U., KINCI, M. F., Bozgeyik, M. B., & Akpak, Y. K. (2026) · BMC Surgery · doi:10.1186/s12893-026-03523-w · Cited by 1
“The AI (artificial intelligence) model achieved a sensitivity of 88.6% and a specificity of 90.0% for predicting obliteration of the Douglas pouch [18].”
InfluentialA Summary of Artificial Intelligence in Gynecologic Surgery
Pipes, G. M., & Kim, K. H. (2026) · Clinical Obstetrics & Gynecology · doi:10.1097/grf.0000000000000986 · Cited by 1
A scoping review on the use of Artificial Intelligence applications in women’s health (MARIE WP1)
Delanerolle, G., Jouaiti, M., Pathiraja, V., Mudalige, T., Eleje, G. U., Mbwele, B., Cavalini, H. F. S., Kurmi, O., Tweneboah-Koduah, F., Mintah-Afful, N., et al. (2026) · Discover Artificial Intelligence · doi:10.1007/s44163-026-01280-6 · Cited by 4
Markov, D., Gurung, J., Khalid, U., Bechev, K. I., Aleksiev, V., Markov, G., & Poryazova, E. (2026) · Diagnostics · doi:10.3390/diagnostics16121823 · Cited by 3
“Imaging-based AI tools may also be affected by differences in ultrasound or MRI equipment, acquisition protocols, operator expertise and image quality, which can reduce reproducibility when applied outside the development environment [22,23,37].”
InfluentialDeslandes, A., Avery, J., O’Hara, R. L., Chen, H., Leonardi, M., Hull, M. L., & Condous, G. S. (2026) · Journal of Endometriosis and Uterine Disorders · doi:10.1016/j.jeud.2026.100174 · Cited by 1
Self-citationAn opportunity for using artificial intelligence in modern gynecology
Ларсеновна, Ш. Ш., Mamchueva, D. K., Vishnevskaya, A. P., Dzhalaeva, K. S., Ramazanova, E. G., Kokaeva, Y. R., Eloeva, Z. M., Aisanova, D. R., Vinogradova, A. S., Tuko, R. R., et al. (2024) · Obstetrics Gynecology and Reproduction · doi:10.17749/2313-7347/ob.gyn.rep.2024.511 · Cited by 3
Aktuelle Aspekte zur künstlichen Intelligenz in der gynäkologischen Diagnostik
Scharf, J. L., Dracopoulos, C., Gembicki, M., Welp, A., & Weichert, J. (2022) · Die Gynäkologie · doi:10.1007/s00129-022-04993-8
“Die im Rahmen der Früherkennung fest etablierten Methoden des Pap(Papanicolaou)-Abstrichs sowie der Kolposkopie mit den daraus resultierenden Datenmengen prädestinieren diese für die automatisierte, diagnostische Auswertung mittels KI [62].”
BackgroundInfluentialNeykhonji, M., Al-Asady, A. M., Avan, A., Khazaei, M., & Hassanian, S. M. (2025) · Current Pharmaceutical Design · doi:10.2174/0113816128354055250312014359
Scovazzi, U., Xholli, A., Schiaffino, M. G., Molinari, F., Perugi, I., Primizia, E., Cagnacci, A., & Londero, A. P. (2025) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2025.03.004
Leveraging AI Models/Tools for Human Fertility
Santosh, K., & Roy, D. G. (2025) · Studies in computational intelligence · doi:10.1007/978-981-95-1248-5_4
Review of Deep Learning Approaches for Endometriosis Lesion Classification
Singh, A., Mann, D., Bajaj, A., Gainder, S., & Malhotra, M. (2026) · Lecture notes in networks and systems · doi:10.1007/978-3-032-30008-9_50
Liang, D., & He, L. (2026) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2026.102601
Unpaired multi-modal multi-label learning for detecting endometriosis signs
Zhang, Y., Wang, H., Xie, Y., To, M., Knox, S., Leonardi, M., Condous, G. S., Avery, J., Hull, M. L., & Carneiro, G. (2026) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2026.103503
Self-citationKarahan, M., Mat, E., Hacıalioğlu, C., Şanlıkan, F., Dereli, M. L., Birol, P., Yıldız, G., & Küçük, H. F. (2026) · Surgical Innovation · doi:10.1177/15533506261476468
Chi, J., Zhang, H., Li, Z., Ling, X., Chen, J., & Huang, Y. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.111381
Liu, D., He, H., Yang, Y., & Ye, Q. (2026) · Medicina · doi:10.3390/medicina62091791
“A positive sliding sign indicates free movement between the uterus and rectum, whereas a negative sliding sign indicates absent movement and may suggest POD obliteration or severe posterior compartment adhesions [5].”
A Staged Deep Learning Framework for Endometriosis-Aware Pelvic MRI Analysis Using UT-EndoMRI
Mursleen, M., & Naseer, I. (2026) · International Journal of Innovations in Science and Technology · doi:10.33411/ijist/2040
Ennes, J. T. M., Benzecry, J. M. D. C., Martins, R. F., Bandeira, L. S., Guttemberg, V. D. V., Costa, T. D. A., de Carvalho, M. G. C., & Ribeiro, L. S. (2026) · Brazilian Journal of Health Review · doi:10.34119/bjhrv9n5-099
Metadata
- Authors
- Maicas, G., Leonardi, M., Avery, J., Panuccio, C., Carneiro, G., Hull, M. L., & Condous, G.
- Affiliations
- The University of Adelaide (AU)
- The University of Sydney (AU)
- 6Specialist Imaging Partners, North Adelaide, Australia
- Women's and Children's Hospital (AU)
- Corresponding author
- Leonardi, Mathew
- ORCID
- Leonardi, Mathew
- Venue
- Reproduction and Fertility
- Publisher
- Bioscientifica
- Published
- 2021-10-19
- Volume
- 2
- Issue
- 4
- Pages
- 236-243
- ISSN
- 2633-8386 (ISSN-L)
- PMC
- PMC8801033
- OpenAlex
- W3196930819
- Cited by
- 41
- References
- 23
- Citations by year
- 2026: 12 · 2025: 11 · 2024: 10 · 2023: 4 · 2022: 4
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- Locations
- Reproduction and Fertility (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Australian Research Council (DP180103232)
- Topics
- Health Sciences › Medicine › Reproductive Medicine › Endometriosis Research and Treatment
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- pouch of Douglas obliteration, sliding sign, endometriosis, transvaginal ultrasound, deep learning, pelvic inflammation, video-based diagnosis, diagnostic accuracy, pelvic adhesions, infertility, dyspareunia, dysmenorrhea, dyschezia, dysuria
- MeSH terms
- Deep Learning, Artificial Intelligence, Cicatrix, Endometriosis, Female, Humans, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.