Correlation between Wave Components of the Second Derivative of Plethysmogram and Arterial Distensibility.
Open accessThe DOI matches its Crossref record.
Abstract
The ratio of two wave components (magnitude of b/a constituting the second derivative of the plethysmogram (SDPTG) was correlated with arterial distensibility. Eighty-two subjects (33-93 years old) were classified into three groups according to the thickness of the intima-media complex of the common carotid artery measured by B-mode ultrasonography. One group was non-atherosclerotic (without pathologic thickening) (nAS) and the other two groups atherosclerotic (mild and severe thickening, or plaque formation) (AS-1 and AS-2). Distensibility (D) of the common carotid artery was calculated from arterial dimensions and blood pressure: h/p = D, where h = (Ds-Dd)/Dd; Ds, Dd and p represent the inner diameter of the carotid artery at peak systole, at end diastole and brachial pulse pressure, respectively. The plethysmogram was recorded at the cuticle of the 2nd digit of the left hand, and the SDPTG was determined with a 10 msec time constant. D showed a significant negative correlation with age in all subjects and in the three separate groups. The correlation between age and magnitude of b/a was significantly negative in all subjects. This negative correlation was not observed in the nAS group, while it was significant in both AS-1 and AS-2. The correlation between magnitude of b/a and D was significantly positive in all subjects and in each group. Significant differences were found among the three groups for magnitude of b/a and D. These results suggest that a decrease in magnitude of b/a or in D was proportional to the thickness of the intima-media complex of the carotid artery, that is, the development of atherosclerosis. These results provide direct evidence that magnitude of b/a of the SDPTG is related to the distensibility of the peripheral artery, and suggest that magnitude of b/a is a useful non-invasive index of atherosclerosis and altered arterial distensibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Contour analysis of the photoplethysmographic pulse measured at the finger
Millasseau, S. C., Ritter, J. M., Takazawa, K., & Chowienczyk, P. J. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000239277.05068.87 · Cited by 354
Methods and devices for measuring arterial compliance in humans
Pannier, B. M., Avolio, A. P., Hoeks, A., Mancia, G., & Takazawa, K. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02962-x · Cited by 343
Metadata
- Authors
- IMANAGA, I., HARA, H., KOYANAGI, S., & TANAKA, K.
- Venue
- Japanese Heart Journal
- Published
- 1998
- Volume
- 39
- Issue
- 6
- Pages
- 775-784
- ISSN
- 0021-4868 (ISSN-L)
- 1348-673X
- OpenAlex
- W2023550153
- Cited by
- 118
- References
- 0
- FWCI
- 0.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation between Wave Components of the Second Derivative of Plethysmogram and Arterial Distensibility. https://app.cochat.ai/papers/10.1536/ihj.39.775
- The paper
- IMANAGA, I., HARA, H., KOYANAGI, S., & TANAKA, K. (1998). Correlation between Wave Components of the Second Derivative of Plethysmogram and Arterial Distensibility. Japanese Heart Journal. https://doi.org/10.1536/ihj.39.775
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.