CoChat

Vital signs monitoring during injectable and inhalant anesthesia in mice

Open access
TSUKAMOTO, Atsushi, SERIZAWA, Kazuya, SATO, Reiichiro, YAMAZAKI, Jumpei, INOMATA, Tomo · 2015 · Experimental Animals
Cited by 124

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Selecting the appropriate anesthetic protocol for the individual animal is an essential part of laboratory animal experimentation. The present study compared the characteristics of four anesthetic protocols in mice, focusing on the vital signs. Thirty-two male ddY mice were divided into four groups and administered anesthesia as follows: pentobarbital sodium monoanaesthesia; ketamine and xylazine combined (K/X); medetomidine, midazolam, and butorphanol combined (M/M/B); and isoflurane. In each group, rectal temperature, heart rate, respiratory rate, and O2 saturation (SPO2) were measured, and the changes over time and instability in these signs were compared. The anesthetic depth was also evaluated in each mouse, and the percentage of mice achieving surgical anesthesia was calculated. K/X anesthesia caused remarkable bradycardia, while the respiratory rate and SPO2 were higher than with the others, suggesting a relatively strong cardiac influence and less respiratory depression. The M/M/B group showed a relatively lower heart rate and SPO2, but these abnormalities were rapidly reversed by atipamezole administration. The pentobarbital group showed a lower SPO2, and 62.5% of mice did not reach a surgical anesthetic depth. The isoflurane group showed a marked decrease in respiratory rate compared with the injectable anesthetic groups. However, it had the most stable SPO2 among the groups, suggesting a higher tidal volume. The isoflurane group also showed the highest heart rate during anesthesia. In conclusion, the present study showed the cardiorespiratory characteristics of various anesthetic protocols, providing basic information for selecting an appropriate anesthetic for individual animals during experimentation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1538/expanim.14-0050

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 124

Metadata

Authors
TSUKAMOTO, A., SERIZAWA, K., SATO, R., YAMAZAKI, J., & INOMATA, T.
Venue
Experimental Animals
Published
2015
Volume
64
Issue
1
Pages
57-64
ISSN
  • 0007-5124 (ISSN-L)
  • 1341-1357
  • 1881-7122
OpenAlex
W2145675697
Cited by
124
References
2
FWCI
4.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vital signs monitoring during injectable and inhalant anesthesia in mice. https://app.cochat.ai/papers/10.1538/expanim.14-0050
The paper
TSUKAMOTO, A., SERIZAWA, K., SATO, R., YAMAZAKI, J., & INOMATA, T. (2015). Vital signs monitoring during injectable and inhalant anesthesia in mice. Experimental Animals. https://doi.org/10.1538/expanim.14-0050

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.