The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abnormal Magnetic Resonance Signal in the Internal Capsule Predicts Poor Neurodevelopmental Outcome in Infants With Hypoxic-Ischemic Encephalopathy
Abstract
Objective. The aim of this study was to establish whether abnormal signal intensity in the posterior limb of the internal capsule (PLIC) on magnetic resonance imaging is an accurate predictor of neurodevelopmental outcome at 1 year of age in infants with hypoxic-ischemic encephalopathy (HIE). Methods. We have examined 73 term neonates with HIE between 1 and 17 days after birth with cranial magnetic resonance imaging and related the magnetic resonance imaging findings to neurodevelopmental outcome at 1 year of age. Results. All infants with an abnormal signal intensity in the PLIC developed neurodevelopmental impairment although in 4 infants with very early scans the abnormal signal was not apparent until up to 4 days after birth. A normal signal intensity was associated with a normal outcome in all but 4 cases; 3 of these infants had minor impairments and all had persistent imaging changes within the white matter. The 4th infant with a normal signal intensity on day 2 died before a further image could be obtained. The absence of normal signal predicted abnormal outcome in term infants with HIE with a sensitivity of 0.90, a specificity of 1.0, a positive predictive value of 1.0, and a negative predictive value of 0.87. The test correctly predicted outcome in 93% of infants with grade II HIE, according to the Sarnat system. Applying a Bayesian approach, the predictive probability of the test (the probability that the test would predict an outcome correctly) was distributed with a mean of 0.94 and 95% confidence limits of 0.89 to 1.0. Conclusion. Abnormal signal intensity in the PLIC is an accurate predictor of neurodevelopmental outcome in term infants suffering HIE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Neonatal Encephalopathy Following Fetal Distress: A Clinical and Electroencephalographic Study
Sarnat, H. B. (1976) · Archives of Neurology · doi:10.1001/archneur.1976.00500100030012 · Cited by 2,680
Chugani, H. T., & Phelps, M. E. (1986) · Science · doi:10.1126/science.3945811 · Cited by 663
Motor recovery following capsular stroke: Role of descending pathways from multiple motor areas
Fries, W., Danek, A., Scheidtmann, K., & Hamburger, C. (1993) · Brain · doi:10.1093/brain/116.2.369 · Cited by 334
COMPARISON OF TWO METHODS OF PREDICTING OUTCOME IN PERINATAL ASPHYXIA
Levene, M. I., Grindulis, H., Sands, C., & Moore, J. R. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90718-x · Cited by 293
Perinatal asphyxia: MR findings in the first 10 days.
Barkovich, A. J., Westmark, K. D., Partridge, C., Sola, A. M., & Ferriero, D. M. (1995) · PubMed · Cited by 279
Cowan, F., Pennock, J., Hanrahan, J., Manji, K., & Edwards, A. (1994) · Neuropediatrics · doi:10.1055/s-2008-1073018 · Cited by 212
Self-citationBrain damage from perinatal asphyxia: correlation of MR findings with gestational age.
Barkovich, A. J., & Truwit, C. L. (1990) · PubMed Central · Cited by 206
MR imaging of the various stages of normal myelination during the first year of life
van der Knaap, M. S., & Valk, J. (1990) · Neuroradiology · doi:10.1007/bf00340123 · Cited by 198
Rutherford, M., Pennock, J., Schwieso, J., Cowan, F., & Dubowitz, L. (1996) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fn.75.3.f145 · Cited by 192
Self-citation
Cited by
Ferriero, D. M. (2004) · New England Journal of Medicine · doi:10.1056/nejmra041996 · Cited by 1,142
Hypoxic-Ischemic Encephalopathy: A Review for the Clinician
Douglas-Escobar, M., & Weiss, M. D. (2015) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2014.3269 · Cited by 778
Origin and timing of brain lesions in term infants with neonatal encephalopathy
Cowan, F., Rutherford, M., Groenendaal, F., Eken, P., Mercuri, E., Bydder, G. M., Meiners, L. C., Dubowitz, L. M., & de Vries, L. S. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12658-x · Cited by 606
Self-citationRutherford, M., Ramenghi, L. A., Edwards, A. D., Brocklehurst, P., Halliday, H., Levene, M., Strohm, B., Thoresen, M., Whitelaw, A., & Azzopardi, D. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70295-9 · Cited by 600
Self-citationPatterns of brain injury in term neonatal encephalopathy
Miller, S. P., Ramaswamy, V., Michelson, D., Barkovich, A. J., Holshouser, B., Wycliffe, N., Glidden, D. V., Deming, D., Partridge, J. C., Wu, Y. W., et al. (2005) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2004.12.026 · Cited by 587
Does training in obstetric emergencies improve neonatal outcome?
Draycott, T., Sibanda, T., Owen, L., Akande, V., Winter, C., Reading, S., & Whitelaw, A. (2006) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2006.00800.x · Cited by 566
Ment, L. R., Bada, H. S., Barnes, P., Grant, P. E., Hirtz, D., Papile, L. A., Pinto–Martin, J., Rivkin, M., & Slovis, T. L. (2002) · Neurology · doi:10.1212/wnl.58.12.1726 · Cited by 456
Johnston, M. V., Trescher, W. H., Ishida, A., Nakajima, W., & Zipursky, A. (2001) · Pediatric Research · doi:10.1203/00006450-200106000-00003 · Cited by 407
Neonatal encephalopathy: An inadequate term for hypoxic–ischemic encephalopathy
Volpe, J. J. (2012) · Annals of Neurology · doi:10.1002/ana.23647 · Cited by 390
Skranes, J., Vangberg, T. R., Kulseng, S., Indredavik, M. S., Evensen, K. A. I., Martinussen, M., Dale, A. M., Haraldseth, O., & Brubakk, A.-M. (2007) · Brain · doi:10.1093/brain/awm001 · Cited by 381
The TOBY Study Group, Azzopardi, D., Brocklehurst, P., Edwards, D., Halliday, H., Levene, M., Thoresen, M., & Whitelaw, A. (2008) · BMC Pediatrics · doi:10.1186/1471-2431-8-17 · Cited by 360
Cerebral Magnetic Resonance Biomarkers in Neonatal Encephalopathy: A Meta-analysis
Thayyil, S., Chandrasekaran, M., Taylor, A., Bainbridge, A., Cady, E. B., Chong, W. K. K., Murad, S., Omar, R. Z., & Robertson, N. J. (2010) · Pediatrics · doi:10.1542/peds.2009-1046 · Cited by 359
Neonatal Hypoxia Ischaemia: Mechanisms, Models, and Therapeutic Challenges
Millar, L. J., Shi, L., Hoerder-Suabedissen, A., & Molnár, Z. (2017) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2017.00078 · Cited by 348
Patterns of Brain Injury in Neonates Exposed to Perinatal Sentinel Events
Okereafor, A., Allsop, J., Counsell, S. J., Fitzpatrick, J., Azzopardi, D., Rutherford, M. A., & Cowan, F. M. (2008) · Pediatrics · doi:10.1542/peds.2007-0770 · Cited by 310
Self-citationExcitotoxicity in Perinatal Brain Injury
Johnston, M. V. (2005) · Brain Pathology · doi:10.1111/j.1750-3639.2005.tb00526.x · Cited by 286
Predicting motor outcome and death in term hypoxic-ischemic encephalopathy
Martinez-Biarge, M., Diez-Sebastian, J., Kapellou, O., Gindner, D., Allsop, J. M., Rutherford, M. A., & Cowan, F. M. (2011) · Neurology · doi:10.1212/wnl.0b013e31821f442d · Cited by 274
Self-citationPatterns of neonatal hypoxic–ischaemic brain injury
de Vries, L. S., & Groenendaal, F. (2010) · Neuroradiology · doi:10.1007/s00234-010-0674-9 · Cited by 262
Bertholdt, S., Latal, B., Liamlahi, R., Pretre, R., Scheer, I., Goetti, R., Dave, H., Bernet, V., Schmitz, A., von Rhein, M., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezt422 · Cited by 64
“PLIC abnormality was defined as the absence of hyperintensity in the PLIC area both on T1 and on T2 [19].”
BackgroundMethodKang, O.-H., Jahn, P., Eichhorn, J. G., Dresbach, T., Müller, A., & Sabir, H. (2023) · Children · doi:10.3390/children10081295 · Cited by 17
“Furthermore, the assessment of the PLIC, which is known to have high predictive value [16,17,27,42,43], is not specifically included in the Barkovich score [30].”
Background
Metadata
- Authors
- Rutherford, M. A., Pennock, J. M., Counsell, S. J., Mercuri, E., Cowan, F. M., Dubowitz, L. M. S., & Edwards, A. D.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 1998-08-01
- Volume
- 102
- Issue
- 2
- Pages
- 323-328
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W1975438937
- Cited by
- 394
- References
- 15
- FWCI
- 9.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.