The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Lung Recruitment and Breathing Pattern During Variable Versus Continuous Flow Nasal Continuous Positive Airway Pressure in Premature Infants: An Evaluation of Three Devices
Abstract
Objective.: To determine whether lung volume changes and breathing pattern parameters differ among 3 devices for delivery of nasal continuous positive airway pressure (CPAP) in premature infants. Methods.: Thirty-two premature infants receiving nasal CPAP for apnea or mild respiratory distress were enrolled. Birth weight was (mean ± standard deviation) 1081 ± 316 g, gestational age 29 ± 2 weeks, age at study 13 ± 12 days, and fraction of inspired oxygen (Fio2) at study .29 ± .1. Three devices, applied in random order, were studied in each infant: continuous flow nasal CPAP via CPAP prongs, continuous flow nasal CPAP via modified nasal cannula, and variable flow nasal CPAP. After lung recruitment to standardize volume history, changes in lung volume (ΔVL) were assessed at nasal CPAP of 8, 6, 4, and 0 cm H2O using calibrated direct current-coupled respiratory inductance plethysmography. Results.: ΔVL was significantly greater overall with the variable flow device compared with both the nasal cannula and CPAP prongs. However, ΔVL was not different between the cannula and the prongs. Respiratory rate, tidal volume, thoraco-abdominal asynchrony, and Fio2 were greater with the modified cannula than for either of the other 2 devices. Conclusion.: Compared with 2 continuous flow devices, the variable flow nasal CPAP device leads to greater lung recruitment. Although a nasal cannula is able to recruit lung volume, it does so at the cost of increased respiratory effort and Fio2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental Design: Procedures for the Behavioral Sciences
Kirk, R. (2013) · doi:10.4135/9781483384733 · Cited by 8,539
Cited by
Research in high flow therapy: Mechanisms of action
Dysart, K., Miller, T. L., Wolfson, M. R., & Shaffer, T. H. (2009) · Respiratory Medicine · doi:10.1016/j.rmed.2009.04.007 · Cited by 742
High flow nasal cannula for respiratory support in preterm infants
Wilkinson, D., Andersen, C., O'Donnell, C. P., De Paoli, A. G., & Manley, B. J. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006405.pub3 · Cited by 368
Global report on preterm birth and stillbirth (3 of 7): evidence for effectiveness of interventions
the GAPPS Review Group, Barros, F. C., Bhutta, Z. A., Batra, M., Hansen, T. N., Victora, C. G., & Rubens, C. E. (2010) · BMC Pregnancy and Childbirth · doi:10.1186/1471-2393-10-s1-s3 · Cited by 300
De Paoli, A. G., Davis, P. G., Argus, B., & Jackson, H. D. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002977.pub2 · Cited by 298
Kawaza, K., Machen, H. E., Brown, J., Mwanza, Z., Iniguez, S., Gest, A., Smith, E. O., Oden, M., Richards-Kortum, R. R., & Molyneux, E. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086327 · Cited by 149
Metadata
- Authors
- Courtney, S. E., Pyon, K. H., Saslow, J. G., Arnold, G. K., Pandit, P. B., & Habib, R. H.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2001-02-01
- Volume
- 107
- Issue
- 2
- Pages
- 304-308
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W1992407558
- Cited by
- 167
- References
- 1
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lung Recruitment and Breathing Pattern During Variable Versus Continuous Flow Nasal Continuous Positive Airway Pressure in Premature Infants: An Evaluation of Three Devices. https://app.cochat.ai/papers/10.1542/peds.107.2.304
- The paper
- Courtney, S. E., Pyon, K. H., Saslow, J. G., Arnold, G. K., Pandit, P. B., & Habib, R. H. (2001). Lung Recruitment and Breathing Pattern During Variable Versus Continuous Flow Nasal Continuous Positive Airway Pressure in Premature Infants: An Evaluation of Three Devices. Pediatrics. https://doi.org/10.1542/peds.107.2.304
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.