CoChat
Cited by 200

The DOI matches its Crossref record.

Bacteremia, Central Catheters, and Neonates: When to Pull the Line

Benjamin, Daniel K., Miller, William, Garges, Harmony, Benjamin, Daniel K., McKinney, Ross E., Cotton, Michael, Fisher, Randall G., Alexander, Kenneth A. · 2001 · Pediatrics

Abstract

Objectives.: Physicians who treat neonates who become bacteremic while dependent on central venous catheters face a serious and common dilemma. We sought 1) to evaluate the relationship between central venous catheter removal and outcome in bacteremic neonates, 2) to determine species of bacteria that are associated with an increased risk of infectious complications if the central catheter is not removed promptly, and 3) to provide evidence-based recommendations for central catheter management. Method.: A retrospective cohort study of all neonates who had central venous access and developed bacteremia between July 1, 1995, and July 31, 1999, was conducted in the Duke University neonatal intensive care unit. Results.: The outcome for patients in whom the central catheter was not removed within 24 hours of organism identification was significantly worse (odds ratio = 9.8) than it was for those whose catheters were removed promptly. For patients who were infected withStaphylococcus aureus or with nonenteric Gram-negative rods, delayed removal of the central catheter was associated with complicated bacteremia. Catheter sterilization was attempted in 27 neonates who were infected with enteric Gram-negative rods; only 10 of these infants retained their catheters without infection-related complications. Infants who had 4 consecutive blood cultures that were positive for coagulase-negative staphylococcus (CoNS) were at significantly increased risk for end-organ damage and death, compared with infants who had 3 or fewer positive blood culture for CoNS (odds ratio = 29.58). Conclusions.: Bacteremic infants experienced fewer infection-related complications when the central catheter was removed promptly. One positive blood culture for Saureus or a Gram-negative rod warrants central line removal in a neonate. Clinicians who are faced with a neonate who has 1 positive culture for CoNS may attempt medical management without central catheter removal, but documentation of subsequent negative blood cultures is crucial. Once a neonate has 3 positive blood cultures for CoNS, the central catheter should be removed.central line, neonate, bacteremia, bacteria, umbilical catheter, Broviac, percutaneous.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.107.6.1272

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Benjamin, D. K., Miller, W., Garges, H., Benjamin, D. K., McKinney, R. E., Cotton, M., Fisher, R. G., & Alexander, K. A.
Venue
Pediatrics
Published
2001-06-01
Volume
107
Issue
6
Pages
1272-1276
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2109655762
Cited by
200
References
0
FWCI
18.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bacteremia, Central Catheters, and Neonates: When to Pull the Line. https://app.cochat.ai/papers/10.1542/peds.107.6.1272
The paper
Benjamin, D. K., Miller, W., Garges, H., Benjamin, D. K., McKinney, R. E., Cotton, M., Fisher, R. G., & Alexander, K. A. (2001). Bacteremia, Central Catheters, and Neonates: When to Pull the Line. Pediatrics. https://doi.org/10.1542/peds.107.6.1272

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.