The DOI matches its Crossref record.
Comparison Between Simultaneously Recorded Amplitude Integrated Electroencephalogram (Cerebral Function Monitor) and Standard Electroencephalogram in Neonates
Abstract
Objective: To assess the value and the limitations of amplitude integrated electroencephalogram (EEG) using the cerebral function monitor (CFM) in comparison with standard EEG in neonates who have hypoxic ischemic encephalopathy or were suspected of having convulsions. Methods. In 36 neonates with a gestational age ≥36 weeks, CFM and simultaneously recorded EEG traces were analyzed off-line and independently classified. CFM background activity: continuous normal voltage; continuous normal voltage, slightly discontinuous (DNV); burst-suppression (BS); continuous extremely low voltage; flat tracing. CFM epileptiform activity: suspected epileptic activity, single seizure (SS), repetitive seizures (RS), status epilepticus (SE). EEG background activity: normal, depressed, low voltage undifferentiated, excessive discontinuity, BS, no activity. Epileptiform activity: interictal unifocal, interictal multifocal, ictal unifocal, ictal multifocal, SE. Results. A total of 33 traces were suitable for analysis. Interobserver agreement on background activity was reached in 31 cases (κ = 0.92) for CFM and in 27 cases (κ = 0.74) for EEG. There was full agreement on CFM ictal activity (RS, SS, or SE) and EEG ictal activity. A normal CFM (continuous normal voltage) corresponded with a normal or a depressed EEG in 90% of the cases. The positive predictive value for a severely abnormal CFM (BS, continuous extremely low voltage, flat tracing) to correspond with a severely abnormal EEG (excessive discontinuity, BS, low voltage undifferentiated, no activity) was 100% (negative predictive value, 80%; sensitivity, 76%; specificity, 100%). DNV (10) on CFM corresponded either with depressed (6) or excessive discontinuity (4) on EEG. Ictal activity on EEG corresponded with SS, RS, or SE on CFM in 8 cases (sensitivity, 80%; specificity, 100%; positive predictive value, 100%; negative predictive value, 92%). Conclusion. CFM is a reliable tool for monitoring both background patterns (especially normal and severely abnormal) and ictal activity. Certain focal, low amplitude, and very short periods of seizure discharges can be missed. We recommend using CFM as a monitoring device and performing intermittent standard EEG whenever there is any doubt about the classification of the CFM (ie, DNV pattern or suspected epileptiform activity).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EEG-based neonatal seizure detection with Support Vector Machines
Temko, A., Thomas, E., Marnane, W., Lightbody, G., & Boylan, G. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.06.034 · Cited by 339
Amplitude-integrated EEG Classification and Interpretation in Preterm and Term Infants
Hellström-Westas, L., Rosén, I., de Vries, L. S., & Greisen, G. (2006) · NeoReviews · doi:10.1542/neo.7-2-e76 · Cited by 329
Self-citation
Metadata
- Authors
- Toet, M. C., van der Meij, W., de Vries, L. S., Uiterwaal, C. S. P. M., & van Huffelen, K. C.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2002-05-01
- Volume
- 109
- Issue
- 5
- Pages
- 772-779
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2171470800
- Cited by
- 302
- References
- 0
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison Between Simultaneously Recorded Amplitude Integrated Electroencephalogram (Cerebral Function Monitor) and Standard Electroencephalogram in Neonates. https://app.cochat.ai/papers/10.1542/peds.109.5.772
- The paper
- Toet, M. C., van der Meij, W., de Vries, L. S., Uiterwaal, C. S. P. M., & van Huffelen, K. C. (2002). Comparison Between Simultaneously Recorded Amplitude Integrated Electroencephalogram (Cerebral Function Monitor) and Standard Electroencephalogram in Neonates. Pediatrics. https://doi.org/10.1542/peds.109.5.772
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.