Comparison Between Simultaneously Recorded Amplitude Integrated Electroencephalogram (Cerebral Function Monitor) and Standard Electroencephalogram in Neonates
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Objective: To assess the value and the limitations of amplitude integrated electroencephalogram (EEG) using the cerebral function monitor (CFM) in comparison with standard EEG in neonates who have hypoxic ischemic encephalopathy or were suspected of having convulsions. Methods. In 36 neonates with a gestational age ≥36 weeks, CFM and simultaneously recorded EEG traces were analyzed off-line and independently classified. CFM background activity: continuous normal voltage; continuous normal voltage, slightly discontinuous (DNV); burst-suppression (BS); continuous extremely low voltage; flat tracing. CFM epileptiform activity: suspected epileptic activity, single seizure (SS), repetitive seizures (RS), status epilepticus (SE). EEG background activity: normal, depressed, low voltage undifferentiated, excessive discontinuity, BS, no activity. Epileptiform activity: interictal unifocal, interictal multifocal, ictal unifocal, ictal multifocal, SE. Results. A total of 33 traces were suitable for analysis. Interobserver agreement on background activity was reached in 31 cases (κ = 0.92) for CFM and in 27 cases (κ = 0.74) for EEG. There was full agreement on CFM ictal activity (RS, SS, or SE) and EEG ictal activity. A normal CFM (continuous normal voltage) corresponded with a normal or a depressed EEG in 90% of the cases. The positive predictive value for a severely abnormal CFM (BS, continuous extremely low voltage, flat tracing) to correspond with a severely abnormal EEG (excessive discontinuity, BS, low voltage undifferentiated, no activity) was 100% (negative predictive value, 80%; sensitivity, 76%; specificity, 100%). DNV (10) on CFM corresponded either with depressed (6) or excessive discontinuity (4) on EEG. Ictal activity on EEG corresponded with SS, RS, or SE on CFM in 8 cases (sensitivity, 80%; specificity, 100%; positive predictive value, 100%; negative predictive value, 92%). Conclusion. CFM is a reliable tool for monitoring both background patterns (especially normal and severely abnormal) and ictal activity. Certain focal, low amplitude, and very short periods of seizure discharges can be missed. We recommend using CFM as a monitoring device and performing intermittent standard EEG whenever there is any doubt about the classification of the CFM (ie, DNV pattern or suspected epileptiform activity).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE CHANGING PANORAMA OF CEREBRAL PALSY IN SWEDEN 1954–1970
HAGBERG, B., HAGBERG, G., & OLOW, I. (1975) · Acta Paediatrica · doi:10.1111/j.1651-2227.1975.tb03820.x · Cited by 480
Assessment of Neonatal Encephalopathy by Amplitude-integrated Electroencephalography
al Naqeeb, N., Edwards, A. D., Cowan, F. M., & Azzopardi, D. (1999) · Pediatrics · doi:10.1542/peds.103.6.1263 · Cited by 458
Toet, M. C., Hellström-Westas, L., Groenendaal, F., Eken, P., & de Vries, L. S. (1999) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fn.81.1.f19 · Cited by 442
Self-citationPilot Study of Treatment With Whole Body Hypothermia for Neonatal Encephalopathy
Azzopardi, D., Robertson, N. J., Cowan, F. M., Rutherford, M. A., Rampling, M., & Edwards, A. D. (2000) · Pediatrics · doi:10.1542/peds.106.4.684 · Cited by 261
Prognostic Value of Background Patterns in the Neonatal EEG
Holmes, G. L., & Lombroso, C. T. (1993) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199307000-00008 · Cited by 259
Eken, P., Toet, M. C., Groenendaal, F., & de Vries, L. S. (1995) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fn.73.2.f75 · Cited by 220
Self-citationEarly serial EEG in hypoxic ischaemic encephalopathy
Pressler, R., Boylan, G. B., Morton, M., Binnie, C. D., & Rennie, J. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00517-4 · Cited by 144
Normal Pattern of the Cerebral Function Monitor Trace in Term and Preterm Neonates
Thornberg, E., & Thiringer, K. (1990) · Acta Paediatrica · doi:10.1111/j.1651-2227.1990.tb11324.x · Cited by 119
Monitoring of cerebral function after severe asphyxia in infancy.
Bjerre, I., Hellström-Westas, L. K., ROSEN, I. A. V., & SVENNINGSEN, N. W. (1983) · Archives of Disease in Childhood · doi:10.1136/adc.58.12.997 · Cited by 114
Cited by
Ferriero, D. M. (2004) · New England Journal of Medicine · doi:10.1056/nejmra041996 · Cited by 1,142
The TOBY Study Group, Azzopardi, D., Brocklehurst, P., Edwards, D., Halliday, H., Levene, M., Thoresen, M., & Whitelaw, A. (2008) · BMC Pediatrics · doi:10.1186/1471-2431-8-17 · Cited by 360
Neonatal Hypoxia Ischaemia: Mechanisms, Models, and Therapeutic Challenges
Millar, L. J., Shi, L., Hoerder-Suabedissen, A., & Molnár, Z. (2017) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2017.00078 · Cited by 348
EEG-based neonatal seizure detection with Support Vector Machines
Temko, A., Thomas, E., Marnane, W., Lightbody, G., & Boylan, G. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.06.034 · Cited by 339
Amplitude-integrated EEG Classification and Interpretation in Preterm and Term Infants
Hellström-Westas, L., Rosén, I., de Vries, L. S., & Greisen, G. (2006) · NeoReviews · doi:10.1542/neo.7-2-e76 · Cited by 329
Self-citation
Metadata
- Authors
- Toet, M. C., van der Meij, W., de Vries, L. S., Uiterwaal, C. S. P. M., & van Huffelen, K. C.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2002-05-01
- Volume
- 109
- Issue
- 5
- Pages
- 772-779
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2171470800
- Cited by
- 302
- References
- 9
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.