The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Accuracy of Bedside Electroencephalographic Monitoring in Comparison With Simultaneous Continuous Conventional Electroencephalography for Seizure Detection in Term Infants
Abstract
OBJECTIVE. Our goals were to compare (1) single-channel amplitude-integrated electroencephalography alone, (2) 2-channel amplitude-integrated electroencephalography alone, and (3) amplitude-integrated electroencephalography plus 2-channel electroencephalography with simultaneous continuous conventional electroencephalography for seizure detection in term infants to check the accuracy of limited channels and compare the different modalities of bedside electroencephalography monitoring. METHODS. Infants referred to a tertiary center with clinical seizures underwent simultaneous continuous conventional electroencephalography and 2-channel (C3-P3 and C4-P4) bedside monitoring. Off-line analysis of the continuous conventional electroencephalographic results was performed independently by 2 neurologists. Two experienced neonatal readers reviewed results obtained with amplitude-integrated electroencephalography and 2-channel electroencephalography combined and single-channel and 2-channel amplitude-integrated electroencephalography. All readings were performed independently and then compared. RESULTS. Twenty-one term newborns were monitored. Seizures were detected in 7 patients who had up to 12 electrical seizures, with 1 infant in status epilepticus. Seizures were identified correctly in 6 of 7 patients with amplitude-integrated electroencephalography plus 2-channel electroencephalography. The missed infant had an isolated 12-second seizure. With amplitude-integrated electroencephalography plus 2-channel electroencephalography, 31 of 41 non–status epilepticus seizures were correctly identified (sensitivity, 76%; specificity, 78%; positive predictive value, 78%; negative predictive value, 78%), with a substantial level of interrater agreement. The seizures missed were predominantly slow sharp waves of occipital origin from a single patient (7 of 10 seizures). Nine false-positive results were obtained in 351 hours of recording (1 false-positive result per 39 hours). These were thought to be related to muscle, electrode, and patting artifacts. Use of amplitude-integrated electroencephalography alone (1 or 2 channel) provided low sensitivity (27%–56%) and low interobserver agreement. CONCLUSIONS. Limited-channel bedside electroencephalography combining amplitude-integrated electroencephalography with 2-channel electroencephalography, interpreted by experienced neonatal readers, detected the majority of electrical seizures in at-risk newborn infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gluckman, P. D., Wyatt, J. S., Azzopardi, D., Ballard, R., Edwards, A. D., Ferriero, D. M., Polin, R. A., Robertson, C. M., Thoresen, M., Whitelaw, A., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)17946-x · Cited by 2,270
Cited by
Shellhaas, R. A., Chang, T., Tsuchida, T., Scher, M. S., Riviello, J. J., Abend, N. S., Nguyen, S., Wusthoff, C. J., & Clancy, R. R. (2011) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31823e96d7 · Cited by 502
EEG-based neonatal seizure detection with Support Vector Machines
Temko, A., Thomas, E., Marnane, W., Lightbody, G., & Boylan, G. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.06.034 · Cited by 339
Treatment advances in neonatal neuroprotection and neurointensive care
Johnston, M. V., Fatemi, A., Wilson, M. A., & Northington, F. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70016-3 · Cited by 278
Metadata
- Authors
- Shah, D. K., Mackay, M. T., Lavery, S., Watson, S., Harvey, A. S., Zempel, J., Mathur, A., & Inder, T. E.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2008-06-01
- Volume
- 121
- Issue
- 6
- Pages
- 1146-1154
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W1971784289
- Cited by
- 219
- References
- 1
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.