Defining the Reference Range for Oxygen Saturation for Infants After Birth
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The goal was to define reference ranges for pulse oxygen saturation (Spo2) values in the first 10 minutes after birth for infants who received no medical intervention in the delivery room. METHODS: Infants were eligible if a member of the research team was available to record Spo2 immediately after birth. Infants were excluded if they received supplemental oxygen or any type of assisted ventilation. Spo2 was measured with a sensor applied to the right hand or wrist as soon as possible after birth; data were collected every 2 seconds. RESULTS: We studied 468 infants and recorded 61650 Spo2 data points. The infants had a mean ± SD gestational age of 38 ± 4 weeks and birth weight of 2970 ± 918 g. For all 468 infants, the 3rd, 10th, 50th, 90th, and 97th percentile values at 1 minute were 29%, 39%, 66%, 87%, and 92%, respectively, those at 2 minutes were 34%, 46%, 73%, 91%, and 95%, and those at 5 minutes were 59%, 73%, 89%, 97%, and 98%. It took a median of 7.9 minutes (interquartile range: 5.0–10 minutes) to reach a Spo2 value of >90%. Spo2 values for preterm infants increased more slowly than those for term infants. We present percentile charts for all infants, term infants of ≥37 weeks, preterm infants of 32 to 36 weeks, and extremely preterm infants of <32 weeks. CONCLUSION: These data represent reference ranges for Spo2 in the first 10 minutes after birth for preterm and term infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing reference centile curves: The lms method and penalized likelihood
Cole, T. J., & Green, P. J. (1992) · Statistics in Medicine · doi:10.1002/sim.4780111005 · Cited by 2,781
Self-citationOxidative Stress in the Newborn – A 30-Year Perspective
Saugstad, O. D. (2005) · Neonatology · doi:10.1159/000087586 · Cited by 355
Room-Air Resuscitation Causes Less Damage to Heart and Kidney than 100% Oxygen
Vento, M., Sastre, J., Asensi, M. A., & Viña, J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200412-1740oc · Cited by 266
Self-citationClinical assessment of infant colour at delivery
O’Donnell, C. P. F., Kamlin, C. O. F., Davis, P. G., Carlin, J. B., & Morley, C. J. (2007) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/adc.2007.120634 · Cited by 265
Self-citationAmerican Heart Association, A. A. O. P. (2006) · Pediatrics · doi:10.1542/peds.2006-0349 · Cited by 265
Resuscitation of Preterm Neonates by Using Room Air or 100% Oxygen
Wang, C. L., Anderson, C., Leone, T. A., Rich, W., Govindaswami, B., & Finer, N. N. (2008) · Pediatrics · doi:10.1542/peds.2007-1460 · Cited by 247
Oxygen saturation trends immediately after birth
Rabi, Y., Yee, W., Chen, S. Y., & Singhal, N. (2006) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2005.12.047 · Cited by 237
Vento, M., Asensi, M. A., Sastre, J., Lloret, A., Garcia-Sala, F., Miñana, J. B., & Viña, J. (2002) · Seminars in Perinatology · doi:10.1053/sper.2002.37312 · Cited by 100
Self-citationContinuous neonatal evaluation in the delivery room by pulse oximetry
House, J. T., Schultetus, R. R., & Gravenstein, N. L. (1987) · The Journal of Clinical Monitoring · doi:10.1007/bf00858357 · Cited by 95
Vento, M., Aguar, M., Leone, T. A., Finer, N. N., Gimeno, A., Rich, W. D., Saenz, P., Escrig, R., & Brugada, M. (2008) · PEDIATRICS · doi:10.1542/peds.2008-1422 · Cited by 78
Self-citationGonzales, G. F., & Salirrosas, A. (2005) · Reproductive Biology and Endocrinology · doi:10.1186/1477-7827-3-46 · Cited by 75
Meier-Stauss, P., Bucher, H. U., Hurlimann, R., König, V., & Huch, R. (1990) · European Journal of Pediatrics · doi:10.1007/bf02072072 · Cited by 71
Saturation by pulse oximetry: Comparison of the results obtained by instruments of different brands
Thilo, E. H., Andersen, D., Wasserstein, M. L., Schmidt, J. M., & Luckey, D. W. (1993) · The Journal of Pediatrics · doi:10.1016/s0022-3476(05)83549-8 · Cited by 61
Australian Resuscitation Council
Oxer, H. F. (1987) · Prehospital and Disaster Medicine · doi:10.1017/s1049023x0002954x · Cited by 49
Monitoring the Resuscitation of Preterm Infants in the Delivery Room Using Pulse Oximetry
Maxwell, L. G., Harris, A. P., SENDAK, M. J., & Donham, R. T. (1987) · Clinical Pediatrics · doi:10.1177/000992288702600102 · Cited by 29
Deckardt, R., Schneider, K. T. M., & Graeff, H. (1987) · Journal of Perinatal Medicine · doi:10.1515/jpme.1987.15.4.357 · Cited by 24
Leone, T. A., & Finer, N. N. (2005) · NeoReviews · doi:10.1542/neo.6-4-e177 · Cited by 17
Leszczyńska‐Gorzelak, B., Poniedziałek‐Czajkowska, E., & Oleszczuk, J. (2002) · Gynecologic and Obstetric Investigation · doi:10.1159/000067884 · Cited by 15
Cited by
European Resuscitation Council Guidelines for Resuscitation 2015
Perkins, G. D., Handley, A. J., Koster, R. W., Castrén, M., Smyth, M. A., Olasveengen, T., Monsieurs, K. G., Raffay, V., Gräsner, J.-T., Wenzel, V., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.015 · Cited by 1,287
European Resuscitation Council Guidelines for Resuscitation 2015
Monsieurs, K. G., Nolan, J. P., Bossaert, L. L., Greif, R., Maconochie, I. K., Nikolaou, N. I., Perkins, G. D., Soar, J., Truhlář, A., Wyllie, J., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.038 · Cited by 915
Snoek, K. G., Reiss, I. K. M., Greenough, A., Capolupo, I., Urlesberger, B., Wessel, L., Storme, L., Deprest, J., Schaible, T., van Heijst, A., et al. (2016) · Neonatology · doi:10.1159/000444210 · Cited by 614
Schmolzer, G. M., Kumar, M., Pichler, G., Aziz, K., O'Reilly, M., & Cheung, P.-Y. (2013) · BMJ · doi:10.1136/bmj.f5980 · Cited by 543
Heart Rate Assessment Immediately after Birth
Phillipos, E., Solevåg, A. L., Pichler, G., Aziz, K., van Os, S., O''Reilly, M., Cheung, P.-Y., & Schmölzer, G. M. (2016) · Neonatology · doi:10.1159/000441940 · Cited by 531
Metadata
- Authors
- Dawson, J. A., Kamlin, C. O. F., Vento, M., Wong, C., Cole, T. J., Donath, S. M., Davis, P. G., & Morley, C. J.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2010-06-01
- Volume
- 125
- Issue
- 6
- Pages
- e1340-e1347
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2154559400
- Cited by
- 553
- References
- 18
- FWCI
- 23.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.