Cited by 7Electronic Health Records SystemsPatient Safety and Medication ErrorsHealthcare Technology and Patient Monitoring

Time for Alert-ology or RE-sensitization?

Lawless, Stephen T.·2013·Pediatrics

Abstract

In their case report in this issue of Pediatrics, Carspecken et al1 describe a child for whom the diagnosis of furosemide allergic hypersensitivity was delayed due to false-positive allergy alert overrides to other drugs. Although articles demonstrating the incidence and prevalence of alert fatigue are not new, I compliment Carspecken for the transparency as to how fatigue from false-positive electronic medical record (EMR) alerts may have adversely affected patient care. I am sure that most of us can review the case report, as can the authors, and will be able to pick apart many case details and see where improvements in the process of care could have been made. As we critique the events as described in this report, I hope that we do so, however, in the spirit of curiosity and in the context of using this case report to foster a culture of safety.The authors have demonstrated a real series of events with alerts that all of those who use an EMR can identify with or are probably fearful about encountering in an inpatient setting. There is now enough evidence to show that, in general, the use of EMR alerts as visual cues is not nearly as effective as initially imagined. Borrowing a term used in psychology, a constant barrage of alerts can “desensitize” us. This case report should serve as a wake-up call to demonstrate how outcomes could be affected as a result of being desensitized.Alerts are designed, for the most part, to guide general decisions similarly to what the early version of care guidelines were meant to accomplish. But, as was the experience with these guidelines, there is often insufficient compliance or applicability to sound bedside clinical judgment. Once someone is desensitized to alerts, however, the significance of these alerts when they are actually true positives can be missed.This case report highlights the need to formally study alternative approaches to the general use of alerts within the EMR. New methods are needed to deliver the message intended by the use of the current EMR alert process, which, as demonstrated in this report, is bringing forth a new type of error that has a real impact on outcomes.At the same time, clinicians must always remember that the EMR and alerts are simply tools to assist in clinical documentation and communication; these tools currently should neither replace nor minimize accountability that occurs through daily physical examination and reassessments. We need to possess self-discipline and foster that discipline in those we train and mentor to rely not on previous clinical decisions but to perhaps use alerts as teaching “cues” to remind us to take a fresh look at our patients, or if an alert is not applicable, then to eliminate it so we do not become desensitized to other more prevalent alerts.If the reliance on alerts results in either the purposeful or fatigue-induced deterioration of clinical assessment and decision-making skills, then alternative messaging techniques should be sought and studied. Much research has been done in the field of desensitization, and now is the time to apply those findings to the use of the EMR.

Integrity signals

Registry

Crossref · 10.1542/peds.2013-0864

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lawless, S. T.
Affiliations
Alfred I. duPont Hospital for Children (US)
Corresponding author
Lawless, Stephen T.
Venue
Pediatrics
Published
2013-06-01
Volume
131
Issue
6
Pages
e1948-e1949
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2074528731
Cited by
7
References
1
Citations by year
2021: 1 · 2020: 1 · 2019: 1 · 2017: 1 · 2016: 1 · 2015: 2
FWCI
1.73
Type
journal article
Language
en
Open access
closed
Locations
  • PEDIATRICS (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
  • Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
Keywords
alarm fatigue, electronic health record alerts, false positive alerts, drug allergy alerts, clinical decision support, drug safety, patient safety culture, clinical judgment, alert override, medication errors, medication reconciliation
MeSH terms
Drug Hypersensitivity, Humans, Male, Medication Errors, Medical Order Entry Systems, Electronic Health Records

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review