Elevated Plasma Aluminum Levels in Normal Infants Receiving Antacids Containing Aluminum
The DOI matches its Crossref record.
Abstract
Aluminum toxicity is a documented cause of encephalopathy, anemia, and osteomalacia. Excretion is primarily renal; therefore, patients with renal insufficiency are at risk for aluminum accumulation and toxicity. This has been demonstrated in uremic children treated with aluminum-containing antacids. The purpose of this study was to determine whether plasma aluminum levels were elevated in infants with normal renal function during prolonged aluminum-containing antacid use. Ten study infants (mean age = 5.8 months), who had been receiving antacids for at least 1 week, were compared with 16 control infants (mean age = 9.8 months) not receiving antacids. The study patients consumed 123 ± 16 mg/kg per day (mean ± SEM) of elemental aluminum for an average of 4.7 weeks. Their plasma aluminum level (37.2 ± 7.13 µg/L) was significantly greater than that of the control group (4.13 ± 0.66 µg/L) (P < .005). It is concluded that plasma aluminum levels may become elevated in infants with normal renal function who are consuming high doses of aluminum-containing antacids. The safety of antacids containing aluminum should not be assumed and they should be used judiciously in infants, with careful monitoring of the aluminum dose and plasma level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rosen, R., Vandenplas, Y., Singendonk, M., Cabana, M., DiLorenzo, C., Gottrand, F., Gupta, S., Langendam, M., Staiano, A., Thapar, N., et al. (2018) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0000000000001889 · Cited by 1,557
Human Health Risk Assessment for Aluminium, Aluminium Oxide, and Aluminium Hydroxide
Krewski, D., Yokel, R. A., Nieboer, E., Borchelt, D., Cohen, J., Harry, J., Kacew, S., Lindsay, J., Mahfouz, A. M., & Rondeau, V. (2007) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937400701597766 · Cited by 998
Vandenplas, Y., Rudolph, C. D., Committee Members:, Di Lorenzo, C., Hassall, E., Liptak, G., Mazur, L., Sondheimer, J., Staiano, A., Thomson, M., et al. (2009) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0b013e3181b7f563 · Cited by 742
Rudolph, C. D., Mazur, L. J., Liptak, G. S., Baker, R. D., Boyle, J. T., Colletti, R. B., Gerson, W. T., & Werlin, S. L. (2001) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/00005176-200100002-00001 · Cited by 626
Gastroesophageal Reflux: Management Guidance for the Pediatrician
Lightdale, J. R., Gremse, D. A., SECTION ON GASTROENTEROLOGY, H., Heitlinger, L. A., Cabana, M., Gilger, M. A., Gugig, R., & Hill, I. D. (2013) · Pediatrics · doi:10.1542/peds.2013-0421 · Cited by 365
Metadata
- Authors
- Tsou, V. M., Young, R. M., Hart, M. H., & Vanderhoof, J. A.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 1991-02-01
- Volume
- 87
- Issue
- 2
- Pages
- 148-151
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2157909850
- Cited by
- 67
- References
- 0
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Elevated Plasma Aluminum Levels in Normal Infants Receiving Antacids Containing Aluminum. https://app.cochat.ai/papers/10.1542/peds.87.2.148
- The paper
- Tsou, V. M., Young, R. M., Hart, M. H., & Vanderhoof, J. A. (1991). Elevated Plasma Aluminum Levels in Normal Infants Receiving Antacids Containing Aluminum. Pediatrics. https://doi.org/10.1542/peds.87.2.148
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.