The DOI matches its Crossref record.
Inadvertent Administration of Positive End-Distending Pressure During Nasal Cannula Flow
Abstract
In the clinical setting, nasal cannulas are frequently used to deliver supplemental oxygen to neonates and are not believed to affect the general respiratory status. In contrast, it was hypothesized that clinical changes associated with nasal cannula gas flow may be related in part to the generation of positive end-distending pressure. To test this hypothesis, alterations in esophageal pressure were quantified as an indication of end-distending pressure and thoracoabdominal motion was quantified as an indication of breathing patterns in 13 preterm infants at gas flow levels of 0.5, 1, and 2 L/min delivered by nasal cannula with an outer diameter of either 0.2 or 0.3 cm. Changes in esophageal pressure were assessed by esophageal balloon manometry. Ventilatory patterns were assessed from thoracoabdominal motion by using respiratory inductive plethysmography. Thoracoabdominal motion was quantitated as a phase angle (Θ); larger values represent greater asynchrony. The 0.2-cm nasal cannula did not deliver pressure or alter thoracoabdominal motion at any flow. In contrast, the 0.3-cm nasal cannula delivered positive end-distending pressure as a function of increasing levels of gas flow (r = .92) and reduced thoracoabdominal motion asynchrony. The mean pressure generated at 2 L/min was 9.8 cm H2O. These data demonstrate that nasal cannula gas flow can deliver positive end-distending pressure to infants and significantly alter their breathing strategy. This finding raises important concerns about the indiscriminate therapeutic use, size selection, and safety of nasal cannulas for the routine delivery of oxygen in preterm infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ekhaguere, O. A., Mairami, A. B., & Kirpalani, H. (2019) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2018.04.004 · Cited by 42
Metadata
- Authors
- Locke, R. G., Wolfson, M. R., Shaffer, T. H., Rubenstein, S. D., & Greenspan, J. S.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 1993-01-01
- Volume
- 91
- Issue
- 1
- Pages
- 135-138
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W1578831726
- Cited by
- 211
- References
- 0
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inadvertent Administration of Positive End-Distending Pressure During Nasal Cannula Flow. https://app.cochat.ai/papers/10.1542/peds.91.1.135
- The paper
- Locke, R. G., Wolfson, M. R., Shaffer, T. H., Rubenstein, S. D., & Greenspan, J. S. (1993). Inadvertent Administration of Positive End-Distending Pressure During Nasal Cannula Flow. Pediatrics. https://doi.org/10.1542/peds.91.1.135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.