Prone or Supine Body Position and Sleep Characteristics in Infants
The DOI matches its Crossref record.
Abstract
Objective. To evaluate the potential relation between body position and sleep characteristics in normal infants. Patients. Two groups of 3-month-old healthy infants were evaluated: 40 infants who usually slept supine, and 40 who usually slept prone. The two groups were matched for gender, gestational age, postnatal age, birth weight, and total recording time. Recording techniques. The 80 infants were studied polygraphically during one night in the pediatric sleep laboratory. They were allowed to fall asleep in their usual sleep position, and every 3 hours were gently turned from prone to supine, or from supine to prone. Results. In each group, 6 infants were excluded from the analysis, because they woke up after having been turned over. In both groups, no significant difference was seen between the prone and the supine body positions for the following variables: number of sleep state changes; number of gross body movements; percent of rapid eye movement sleep; saturation with oxygen, arterial blood levels; number and duration of acid esophageal reflux; rectal temperature; mean respiratory rates; water evaporation rates from the forehead skin; and number or duration of central or of obstructive apneas. In both groups of infants, prone body position was associated with a significant increase in sleep duration (+ 6%) and in non-rapid eye movement sleep (+25%) and a significant decrease in number of arousals (–40%) and in their duration (–43%). Conclusions. No explanation has been found for the sleep-promoting effect of prone body positioning. The finding could be of interest to the study of infants' sleep quality, as well as to the potential relation between body positions and sudden death during sleep.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fleming, S., Thompson, M., Stevens, R., Heneghan, C., Plüddemann, A., Maconochie, I., Tarassenko, L., & Mant, D. (2011) · The Lancet · doi:10.1016/s0140-6736(10)62226-x · Cited by 1,282
Moon, R. Y., & Task Force on Sudden Infant Death Syndrome (2011) · Pediatrics · doi:10.1542/peds.2011-2284 · Cited by 734
Moon, R. Y., TASK FORCE ON SUDDEN INFANT DEATH SYNDROME, Darnall, R. A., Feldman-Winter, L., Goodstein, M. H., & Hauck, F. R. (2016) · Pediatrics · doi:10.1542/peds.2016-2940 · Cited by 583
Moon, R. Y., Horne, R. S., & Hauck, F. R. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61662-6 · Cited by 365
Øyen, N., Markestad, T., PhD, R. S., Irgens, L. M., Helweg-Larsen, K., Alm, B., Norvenius, G., & Wennergren, G. (1997) · Pediatrics · doi:10.1542/peds.100.4.613 · Cited by 246
Metadata
- Authors
- Kahn, A., Groswasser, J., Sottiaux, M., Rebuffat, E., Franco, P., & Dramaix, M.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 1993-06-01
- Volume
- 91
- Issue
- 6
- Pages
- 1112-1115
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W1790058821
- Cited by
- 140
- References
- 0
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prone or Supine Body Position and Sleep Characteristics in Infants. https://app.cochat.ai/papers/10.1542/peds.91.6.1112
- The paper
- Kahn, A., Groswasser, J., Sottiaux, M., Rebuffat, E., Franco, P., & Dramaix, M. (1993). Prone or Supine Body Position and Sleep Characteristics in Infants. Pediatrics. https://doi.org/10.1542/peds.91.6.1112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.