Noninvasive Monitoring of Oxygenation in Infants and Children: Practical Considerations and Areas of Concern
Abstract
Objective. To review the technical principles of transcutaneous Po2 (tcPo2) monitors and pulse oximeters and to discuss methodological and practical issues related to the use of these devices in infants and children. Design. Literature review and summary of personal experience. Results. tcPo2 measurements are influenced by skin thickness, sensor temperature, amount of contact gel used, and state of peripheral perfusion. The average in vivo response time to a rapid decrease in Pao2 is approximately 16 seconds. Sensitivity to both hypoxemia (Pao2 < 50 mm Hg) and hyperoxemia (Pao2 > 80 to 100 mm Hg) is approximately 85%. Pulse oximeters require careful sensor placement (to avoid optical shunts) and adequate pulse pressures (> 20 mm Hg). They are prone to movement artifact. There are considerable differences in bias and precision between different brands, resulting, for example, in quite different upper alarm limits required to detect hyperoxemia reliably. The normal range of oxygen saturation measured by pulse oximetry, measured with one brand of pulse oximeter (Nellcor) during regular breathing, is 95% to 100% in preterm infants and 97% to 100% in full-term infants and children. Conclusions. Because both devices have their specific shortfalls, they should ideally be used in combination, particularly in critically ill preterm neonates. Where this is not feasible or necessary, clinicians must be aware of the limitations of the device they are using.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pulse oximetry: fundamentals and technology update
Nitzan, M., Romem, A., & Koppel, R. (2014) · Medical Devices: Evidence and Research · doi:10.2147/mder.s47319 · Cited by 438
Tin, W., Milligan, D. W. A., Pennefather, P., & Hey, E. (2001) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fn.84.2.f106 · Cited by 432
Statement on the Care of the Child with Chronic Lung Disease of Infancy and Childhood
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.168.3.356 · Cited by 338
Monitoring in the Intensive Care
Kipnis, E., Ramsingh, D., Bhargava, M., Dincer, E., Cannesson, M., Broccard, A., Vallet, B., Bendjelid, K., & Thibault, R. (2012) · Critical Care Research and Practice · doi:10.1155/2012/473507 · Cited by 87
Noninvasive Monitoring and Assessment of Oxygenation in Infants
Poets, C. F. (2019) · Clinics in Perinatology · doi:10.1016/j.clp.2019.05.010 · Cited by 24
Self-citation
Metadata
- Authors
- Poets, C. F., & Southall, D. P.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 1994-05-01
- Volume
- 93
- Issue
- 5
- Pages
- 737-746
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W1516784036
- Cited by
- 198
- References
- 0
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Monitoring of Oxygenation in Infants and Children: Practical Considerations and Areas of Concern. https://app.cochat.ai/papers/10.1542/peds.93.5.737
- The paper
- Poets, C. F., & Southall, D. P. (1994). Noninvasive Monitoring of Oxygenation in Infants and Children: Practical Considerations and Areas of Concern. Pediatrics. https://doi.org/10.1542/peds.93.5.737
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.