Biodegradable Polymer Composites for Temporary Replacement of Trabecular Bone: The Effect of Polymer Molecular Weight on Composite Strength and Modulus
Abstract
Our laboratory has been developing a particulate composite material as a temporary replacement for trabecular bone. The material is degradable in physiologic fluids, and uses starting materials that the body can metabolize and excrete. This study investigates the influence of the molecular weight of one component, a linear polyester, on the mechanical strength of the composite material. The compressive strength and modulus increase from “low” to “medium” molecular weight, but do not increase further from “medium” to “high” molecular weight. Low, medium, and high are relative to the highest molecular weight attainable with the current reaction scheme, which is a number average molecular weight (M n) of 2,038 and a weight average molecular weight (M w) of 11,916.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Still being checked.
Cited by
Sorted by citations
Biodegradable synthetic polymers for tissue engineering
CSIRO Molecular Science, B. 1., & Gunatillake, P. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a01 · Cited by 1,765 · see citing works
Yaszemski, M. J., Payne, R. G., Hayes, W. C., Langer, R., Aufdemorte, T. B., & Mikos, A. G. (1995) · Tissue Engineering · doi:10.1089/ten.1995.1.41 · Cited by 149 · see citing works
Self-citationCharacterization of partially saturated poly(propylene fumarate) for orthopaedic application
Peter, S. J., Yaszemski, M. J., Suggs, L. J., Payne, R. G., Langer, R., Hayes, W. C., Unroe, M. R., Alemany, L. B., Engel, P. S., & Mikos, A. G. (1997) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856297x00074 · Cited by 84 · see citing works
Self-citationXu, B., Lee, K., Li, W., Yaszemski, M. J., Lu, L., Yang, Y., & Wang, S. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.110150 · Cited by 40 · see citing works
Self-citationSuggs, L. J., Payne, R. G., Kao, E. Y., Alemany, L. B., Yaszemski, M. J., Wu, K. K., & Mikos, A. G. (1995) · MRS Proceedings · doi:10.1557/proc-394-167
Self-citation
- Authors
- Yaszemski, M. J., Mikos, A. G., Payne, R. G., & Hayes, W. C.
- Affiliations
- Harvard University (US)
- Rice University (US)
- Wilford Hall Ambulatory Surgical Center (US)
- Corresponding author
- Yaszemski, Michael J.
- Venue
- MRS Proceedings
- Published
- 1993
- Volume
- 331
- ISSN
- 0272-9172 (ISSN-L)
- 1946-4274
- OpenAlex
- W2334523411
- Cited by
- 5
- References
- 0
- Citations by year
- 2021: 1
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- MRS Proceedings (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- biodegradable polymer composites, molecular weight effects, linear polyesters, compressive strength, elastic modulus, particle-reinforced composites, mechanical properties
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›