Behavior of Magnetorheological Fluids
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
In the absence of an applied magnetic field, magnetorheological (MR) fluids typically behave as nearly ideal Newtonian liquids. The application of a magnetic field induces magnetic dipole and multipole moments on each particle. The anisotropic magnetic forces between pairs of particles promote the head-to-tail alignment of the moments and draws the particles into proximity. These attractive interparticle forces lead to the formation of chains, columns, or more complicated networks of particles aligned with the direction of the magnetic field. When these structures are deformed mechanically, magnetic restoring forces tend to oppose the deformation. Substantial field-dependent enhancements of the rheological properties of these materials result, as demonstrated in Figure 1. The myriad potential applications of MR and electrorheological (ER) fluids provide considerable motivation for research on these materials. The availability of fluids with yield stresses or apparent viscosities that are controllable over many orders of magnitude by applied fields enables the construction of electromechanical devices that are engaged and controlled by electrical signals and that require few or no moving parts. Potential automotive applications include electrically engaged clutches for vehicle powertrains and engine accessories as well as semiactive shock absorbers that can adapt in real time to changing road conditions. Semiactive dampers for rotorcraft control surfaces are among the potential aerospace applications. The critical need to mitigate the structural vibrations of large structures has led to the construction of large, high-force MR-fluid-based dampers. A promising application in manufacturing processes is the computer-aided polishing of precision optics in which abrasive particles are suspended in an MR fluid so that the polishing rate is determined in part by the strength of an applied magnetic field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rheology: Principles, Measurements, and Applications
Macosko, C. W. (1994) · Cited by 3,474
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786
A model of the behaviour of magnetorheological materials
Jolly, M. R., Carlson, J. D., & Muñoz, B. C. (1996) · Smart Materials and Structures · doi:10.1088/0964-1726/5/5/009 · Cited by 968
COMMERCIAL MAGNETO-RHEOLOGICAL FLUID DEVICES
Carlson, J. D., Catanzarite, D. M., & Clair, K. A. S. (1996) · International Journal of Modern Physics B · doi:10.1142/s0217979296001306 · Cited by 546
Shear stresses in magnetorheological fluids: Role of magnetic saturation
Ginder, J. M., & Davis, L. C. (1994) · Applied Physics Letters · doi:10.1063/1.112408 · Cited by 349
Self-citationER fluid requirements for automotive devices
Hartsock, D. L., Novak, R., & Chaundy, G. J. (1991) · Journal of Rheology · doi:10.1122/1.550232 · Cited by 122
Yield stress and wall effects in magnetic colloidal suspensions
Lemaire, E., & Bossis, G. (1991) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/24/8/037 · Cited by 92
Nonlinear interactions of particles in chains
Jones, T. B., & Saha, B. (1990) · Journal of Applied Physics · doi:10.1063/1.346836 · Cited by 64
Metadata
- Authors
- Ginder, J. M.
- Venue
- MRS Bulletin
- Published
- 1998-08
- Volume
- 23
- Issue
- 8
- Pages
- 26-29
- ISSN
- 0883-7694 (ISSN-L)
- 1938-1425
- OpenAlex
- W2098267972
- Cited by
- 189
- References
- 8
- FWCI
- 16.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Behavior of Magnetorheological Fluids. https://app.cochat.ai/papers/10.1557/s0883769400030785
- The paper
- Ginder, J. M. (1998). Behavior of Magnetorheological Fluids. MRS Bulletin. https://doi.org/10.1557/s0883769400030785
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.