The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Preliminary studies and potential applications of localized surface plasmon resonance spectroscopy in medical diagnostics
Abstract
Miniature optical sensors that specifically identify low concentrations of environmental and biological substances are in high demand. Currently, there is no optical sensor that provides identification of the aforementioned species without amplification techniques at naturally occurring concentrations. Recently, it has been demonstrated that triangular silver nanoparticles have remarkable optical properties and that their enhanced sensitivity to their nanoenvironment has been used to develop a new class of optical sensors using localized surface plasmon resonance spectroscopy. The examination of both model and nonmodel biological assays using localized surface plasmon resonance spectroscopy will be presented in this review. It will be demonstrated that the use of a localized surface plasmon resonance nanosensor rivals the sensitivity and selectivity of, and provides a low-cost alternative to, commercially available sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alzheimer's disease: the amyloid cascade hypothesis
Hardy, J. A., & Higgins, G. A. (1992) · Science · doi:10.1126/science.1566067 · Cited by 7,484
Diffusible, nonfibrillar ligands derived from Aβ 1–42 are potent central nervous system neurotoxins
Lambert, M. P., Barlow, A. K., Chromy, B. A., Edwards, C., Freed, R., Liosatos, M., Morgan, T. E., Rozovsky, I., Trommer, B., Viola, K. L., et al. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.11.6448 · Cited by 3,506
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Self-citationGong, Y., Chang, L., Viola, K. L., Lacor, P. N., Lambert, M. P., Finch, C. E., Krafft, G. A., & Klein, W. L. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1834302100 · Cited by 1,061
Targeting small Aβ oligomers: the solution to an Alzheimer's disease conundrum?
Klein, W. (2001) · Trends in Neurosciences · doi:10.1016/s0166-2236(00)01749-5 · Cited by 989
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Localized Surface Plasmon Resonance Sensors
Mayer, K. M., & Hafner, J. H. (2011) · Chemical Reviews · doi:10.1021/cr100313v · Cited by 4,350
Biomedical Applications of Plasmon Resonant Metal Nanoparticles
Liao, H., Nehl, C. L., & Hafner, J. H. (2006) · Nanomedicine · doi:10.2217/17435889.1.2.201 · Cited by 396
Implications of Nanobiosensors in Agriculture
Rai, V., Acharya, S., & Dey, N. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.322039 · Cited by 332
Metadata
- Authors
- Haes, A. J., & Duyne, R. P. V.
- Venue
- Expert Review of Molecular Diagnostics
- Publisher
- Informa UK Limited
- Published
- 2004-07
- Volume
- 4
- Issue
- 4
- Pages
- 527-537
- ISSN
- 1473-7159 (ISSN-L)
- 1744-8352
- OpenAlex
- W2077212608
- Cited by
- 182
- References
- 5
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preliminary studies and potential applications of localized surface plasmon resonance spectroscopy in medical diagnostics. https://app.cochat.ai/papers/10.1586/14737159.4.4.527
- The paper
- Haes, A. J., & Duyne, R. P. V. (2004). Preliminary studies and potential applications of localized surface plasmon resonance spectroscopy in medical diagnostics. Expert Review of Molecular Diagnostics. https://doi.org/10.1586/14737159.4.4.527
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.