Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 415

The DOI matches its Crossref record.

Bone reconstruction: from bioceramics to tissue engineering

El-Ghannam, Ahmed·2005·Expert Review of Medical Devices

Abstract

Over the past 30 years, an enormous array of biomaterials proposed as ideal scaffolds for cell growth have emerged, yet few have demonstrated clinical efficacy. Biomaterials, regardless of whether they are permanent or biodegradable, naturally occurring or synthetic, need to be biocompatible, ideally osteoinductive, osteoconductive, integrative, porous and mechanically compatible with native bone to fulfill their desired role in bone tissue engineering. These materials provide cell anchorage sites, mechanical stability and structural guidance and in vivo, provide the interface to respond to physiologic and biologic changes as well as to remodel the extracellular matrix in order to integrate with the surrounding native tissue. Calcium phosphate ceramics and bioactive glasses were introduced more than 30 years ago as bone substitutes. These materials are considered bioactive as they bond to bone and enhance bone tissue formation. The bioactivity property has been attributed to the similarity between the surface composition and structure of bioactive materials, and the mineral phase of bone. The drawback in using bioactive glasses and calcium phosphate ceramics is that close proximity to the host bone is necessary to achieve osteoconduction. Even when this is achieved, new bone growth is often strictly limited because these materials are not osteoinductive in nature. Bone has a vast capacity for regeneration from cells with stem cell characteristics. Moreover, a number of different growth factors including bone morphogenetic proteins, have been demonstrated to stimulate bone growth, collagen synthesis and fracture repair both in vitro and in vivo. Attempts to develop a tissue-engineering scaffold with both osteoconductivity and osteoinductivity have included loading osteoinductive proteins and/or osteogenic cells on the traditional bioactive materials. Yet issues that must be considered for the effective application of bioceramics in the field of tissue engineering are the degree of bioresorption and the poor mechanical strength. The synthesis of a new generation of biomaterials that can specifically serve as tissue engineering scaffolds for drug and cell delivery is needed. Nanotechnology can provide an alternative way of processing porous bioceramics with high mechanical strength and enhanced bioactivity and resorbability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1586/17434440.2.1.87

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 415

Metadata

Authors
El-Ghannam, A.
Venue
Expert Review of Medical Devices
Published
2005-01
Volume
2
Issue
1
Pages
87-101
ISSN
  • 1743-4440 (ISSN-L)
  • 1745-2422
OpenAlex
W2126071587
Cited by
415
References
0
FWCI
13.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bone reconstruction: from bioceramics to tissue engineering. https://app.cochat.ai/papers/10.1586/17434440.2.1.87
The paper
El-Ghannam, A. (2005). Bone reconstruction: from bioceramics to tissue engineering. Expert Review of Medical Devices. https://doi.org/10.1586/17434440.2.1.87

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.