PRECICE intramedullary limb lengthening system
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The PRECICE(®) Intramedullary Limb Lengthening System (Ellipse Technologies Inc., CA, USA) is a remotely controlled, magnetically driven, implantable limb lengthening intramedullary nail system. It has both CE mark and US FDA clearance for its first- (2011) and second-generation (2013) implants. It is indicated for the treatment of limb length discrepancy and short stature. It has been used worldwide in over 1000 cases. Its reported and published results in over 250 cases has been excellent with less pain and lower complication rates than with external fixation methods or previous implantable nail systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gralton, B. (2008) · Art monthly Australia · Cited by 3,001
Problems, Obstacles, and Complications of Limb Lengthening by the Ilizarov Technique
PALEY, D. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199001000-00011 · Cited by 1,499 · cited 1×
“[18].”
Self-citationCheung, K. M.-C., Cheung, J. P.-Y., Samartzis, D., Mak, K.-C., Wong, Y.-W., Cheung, W.-Y., Akbarnia, B. A., & Luk, K. D.-K. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60112-3 · Cited by 326 · cited 1×
“They used the same mechanism that they had developed for their spinal growing rod called ‘the MAGEC System’ [1].”
MethodA Fully Implantable Motorized Intramedullary Nail for Limb Lengthening and Bone Transport
Baumgart, R., Betz, A., & Schweiberer, L. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199710000-00023 · Cited by 227 · cited 1×
“Baumgart’s cohort of 12 patients attained complete length objectives in all patients [2].”
BackgroundCole, J. D., Justin, D., Kasparis, T., DeVlught, D., & Knobloch, C. (2001) · Injury · doi:10.1016/s0020-1383(01)00116-4 · Cited by 210 · cited 3×
“The article by the ISKD’s designer (Cole) reviewed his initial series of 20 nails in 18 patients [34].”
BackgroundGRADUAL FEMORAL LENGTHENING WITH THE ALBIZZIA INTRAMEDULLARY NAIL
GUICHET, J.-M., DEROMEDIS, B., DONNAN, L. T., PERETTI, G., LASCOMBES, P., & BADO, F. (2003) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200305000-00011 · Cited by 164
What’s New in Limb Lengthening and Deformity Correction
Sabharwal, S., Nelson, S. C., & Sontich, J. K. (2015) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.o.00298 · Cited by 81
Cited by
Achondroplasia: Development, pathogenesis, and therapy
Ornitz, D. M., & Legeai‐Mallet, L. (2017) · Developmental Dynamics · doi:10.1002/dvdy.24479 · Cited by 259
Glatt, V., Evans, C. H., & Tetsworth, K. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2016.00678 · Cited by 194
“…nail. various implants available use different strategies to provide the necessary distraction force, including mechanical, motorized, or magnetic devices (Betz et al., 1990; Baumgart et al., 1997; Cole et al., 2001; Thaller et al., 2014; Kucukkaya et al., 2015; Paley, 2015; Paley et al., 2015).”
BackgroundMethodInfluential
Metadata
- Authors
- Paley, D.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2015-02-18
- Volume
- 12
- Issue
- 3
- Pages
- 231-249
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2136245126
- Cited by
- 200
- References
- 7
- FWCI
- 12.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.